NAME
Moire fringes, moire
DESCRIPTION
Superimposed signals of different phases
A moiré pattern is an interference pattern created for example when two grids are overlaid at an angle, or when they have slightly different mesh sizes. The human visual system creates an imaginary pattern of roughly horizontal dark and light bands, the moiré pattern that appears to be superimposed on the lines.
In MRI, the appearance of moiré fringes can be caused by a variety of reasons e.g., inhomogeneity of the main magnetic field caused by a defect shielding ( interference with RF pulses), interferences produced by aliasing, and interferences of echoes from different excitation modes (with different echo times).
Image Guidance
| | | | | Further Reading: | Basics:
|
|
| |
| | | | | |
| |
|
Quick Overview
DESCRIPTION
Bands through image center
Zipper artifacts appear as dashed lines. There are various causes for this MRI artifact.
Most of zipper artifacts result from inhomogeneities of the magnetic field caused by interferences with radio frequency from various sources ('your radio is working in the scanner room means your shielding is not working'). Software and equipment problems can also cause zipper lines in both directions.
Image Guidance
| | | | | |
| | | | | |
| |
|
Quick Overview Please note that there are different common names for this artifact.
DESCRIPTION
Static on the image
REASON
Electromagnetic emissions
HELP
Shielding, eliminate the factor of disturbance
RF noise, which often appears as static on the image, can be caused by a medical device located anywhere in the MR procedure room.
RF noise is a result of excessive electro magnetic emissions from the device that interference with the proper operation of the MR scanner.
The interference is attenuated and aliased in the frequency direction.
Image Guidance
| | | | • View the DATABASE results for 'Radio Frequency Noise Artifact' (3).
| | | | Further Reading: | Basics:
|
|
| |
| | | Searchterm 'Magnetic Shielding' was also found in the following services: | | | | |
| | |
| |
|
| | | | | | | | | • View the DATABASE results for 'MRI Equipment' (13).
| | | • View the NEWS results for 'MRI Equipment' (4).
| | | | Further Reading: | News & More:
|
|
| |
| | | | |
| |
| | | |
|
| |
| Look Ups |
| |
|
MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies. | | [last update: 2024-02-26 03:41:00] |
|
|