O-SCAN™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, etc.
 
www.fonar.com/standup.htm www.fonar.com/standup.htm O-scan is manufactured and distributed by Esaote SpA
O-scan is a compact, dedicated extremity MRI system designed for easy installation and high throughput. The complete system fits in a 9' x 10' room, doesn't need for RF or magnetic shielding and it plugs in the wall. The 0.31T permanent magnet along with dual phased array RF coils, and advanced imaging protocols provide outstanding image quality and fast 25 minute complete examinations.
Esaote North America is the exclusive distributor of the O-scan system in the USA.

Device Information and Specification
CLINICAL APPLICATION Dedicated Extremity
CONFIGURATION Closed
SURFACE COILS Dual phased array knee, hand, foot//ankle/elbow
PULSE SEQUENCES SE, HSE, HFE, GE, 2dGE, ME, IR, STIR, Stir T2, GESTIR, TSE, TME, FSE STIR, FSE (T1, T2), X-Bone, Turbo 3DT1, 3D SHARC, 3D SST1, 3D SST2
IMAGING MODES 2D, 3D multi-plane, half echo, half scan, real time
TR 10 - 10,000 msec.
TE 6 - 220 msec.
SINGLE SLICE 0.1 sec.
MULTI SLICE 0.1 sec.
FOV 14 cm
SLICE THICKNESS 2D: 2mm - 10 mm, 3D: 0.6 - 10 mm
DISPLAY MATRIX 512 x 512
MEASURING MATRIX 512 x 512 max.
PIXEL INTENSITY 4,096 grey levels
SPATIAL RESOLUTION 0.2 mm
MAGNET TYPE Permanent - NdFeB
MAGNET WEIGHT 2,733 lbs
POWER REQUIREMENTS 100/110/200/220/230/240
FIELD STRENGTH 0.31T
STRENGTH 20 mT/m
5 GAUSS FRINGE FIELD, radial/axial 67 cm / 75 cm
SHIMMING passive
spacer
Oblique
 
A plane or section not perpendicular to the xyz coordinate system, such as long and short axis views of the heart.
spacer

• View the DATABASE results for 'Oblique' (22).Open this link in a new window

 
Further Reading:
  Basics:
Additional oblique MRI improved diagnosis of ACL tears
Friday, 7 June 2013   by www.healio.com    
MRI Resources 
Pediatric and Fetal MRI - Crystallography - Sequences - Spectroscopy - Liver Imaging - Education pool
 
Oblique Imaging
 
Oblique imaging generates images along oblique orientations between the conventional planes.
spacer
 
Further Reading:
  Basics:
Magnetic resonance imaging
   by www.scholarpedia.org    
  News & More:
Cutting Edge Imaging of THE Spine
February 2007   by www.pubmedcentral.nih.gov    
Odin Medical Technologies, Inc.MRI Resource Directory:
 - Manufacturers -
 
www.odinmed.com/site/index.asp Odin Medical Technologies, Ltd. was founded in Israel, in 1996. Odin Medical Technologies, Inc. was established in early 2000 in the United States as a wholly owned subsidiary.
Odin Medical Technologies develops and manufactures intraoperative magnetic resonance imaging (MRI) image guidance systems designed to improve neurosurgical interventions with a special focus on minimally invasive procedures.

MRI Related Product Line:
PoleStar™

Contact Information
MAIL Odin Medical Technologies, Inc.
29 Crafts Street,
Suite 420
Newton, MA 02458
USA
PHONE +1-617-527-1785
Toll Free(USA): 877-329-6346
FAX +1-617-527-1786
Contact Form Contact Us
ONLINE www.odinmed.com

spacer

• View the DATABASE results for 'Odin Medical Technologies, Inc.' (2).Open this link in a new window

Off Resonance
 
A state occurring when the Larmor frequency of a spin isochromat is different from that of the exciting RF field. See also Magnetization Transfer Contrast.
spacer

• View the NEWS results for 'Off Resonance' (15).Open this link in a new window.

• View the DATABASE results for 'Off Resonance' (5).Open this link in a new window

 
Further Reading:
  Basics:
Factors influencing flip angle mapping in MRI: RF pulse shape, slice-select gradients, off-resonance excitation, and B0 inhomogeneities.
Tuesday, 1 August 2006   by www.ncbi.nlm.nih.gov    
MRI Resources 
Safety pool - Intraoperative MRI - Liver Imaging - Shielding - Manufacturers - IR
 
    1 - 5 (of 27)      next 
 O--Of    Of-ON   OP-Op   Or-Os   Os-Ou   Ov-Ox   
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



Acoustic Noise Reduction (Silent, Quiet, etc.) :
cannot get better 
is in its first steps 
is done by earplugs, headphones 
must get better 
is bad, I miss something 
is unnecessary 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2003 - 2016 SoftWays. All rights reserved. [ 27 May 2017]
Terms of Use | Privacy Policy | Advertising
 [last update: 2017-05-22 05:06:00]