Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Ferumoxsil' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Ferumoxsil' found in 1 term [] and 4 definitions []
1 - 5 (of 5)     
Result Pages : [1]
MRI Resources 
Breast MRI - Absorption and Emission - MR Myelography - Safety Products - Jobs pool - Colonography
 
FerumoxsilInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
(GastroMARK®, Lumirem®) A superparamagnetic MRI contrast agent for the gastrointestinal tract.

See also Oral Contrast Agents.
spacer
 
• Share the entry 'Ferumoxsil':  Facebook  Twitter  LinkedIn  
MRI Resources 
MR Myelography - Shoulder MRI - Spine MRI - MR Guided Interventions - Intraoperative MRI - DICOM
 
GastroMARK®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
GastroMARK® belongs to the negative oral contrast agents (same as Lumirem®, another brand name for ferumoxsil). GastroMARK® is used to distinguish the loops of the bowel from other abdominal structures and physiology. When GastroMARK® is ingested, it flows through and darkens the stomach and the small intestine in 30 to 45 minutes. By more clearly identifying the intestinal loops, GastroMARK® improves visualization of adjacent abdominal tissues such as the pancreas.
Drug Information and Specification
NAME OF COMPOUND
Ferumoxsil, silicone-coated superparamagnetic iron oxide, USAN, AMI-121
CENTRAL MOIETY
Fe3+/Fe2+
CONTRAST EFFECT
T2*enhanced
r1=3.4, r2=3.8, B0=1.0T
PHARMACOKINETIC
Gastrointestinal
OSMOLALITY
250 mosm/kgH2O
CONCENTRATION
52.5mg Fe/300mL
DOSAGE
300 mL oral
PREPARATION
Finished product
INDICATION
Bowel marking
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Bottles containing 300 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
GastroMARK®
For sale
EU
For sale
spacer

• View the DATABASE results for 'GastroMARK®' (6).Open this link in a new window

 
Further Reading:
  Basics:
ferumoxsil, oral suspension GastroMARK GastroMARK ®
MATERIAL SAFETY DATA SHEET
   by dailymed.nlm.nih.gov    
MRI Resources 
Corporations - Mass Spectrometry - Safety Products - MR Guided Interventions - Chemistry - Liver Imaging
 
Lumirem®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Lumirem® belongs to the negative oral contrast agents (same as GastroMARK®, another brand name for ferumoxsil). Lumirem® is used to distinguish the loops of the bowel from other abdominal structures and physiology. When Lumirem® is ingested, it flows through and darkens the stomach and the small intestine in 30 to 45 minutes. By more clearly identifying the intestinal loops, Lumirem® improves visualization of adjacent abdominal tissues such as the pancreas.
Additionally, in Europe Lumirem® is approved for rectal administration to delineate the lower intestinal system.
Drug Information and Specification
NAME OF COMPOUND
Ferumoxsil (USAN, SPIO), AMI-121
CENTRAL MOIETY
Fe3+/Fe2+
CONTRAST EFFECT
T2*enhanced
r1=3.4, r2=3.8, B0=1.0T
PHARMACOKINETIC
Gastrointestinal
CONCENTRATION
52.5mg Fe/300mL
DOSAGE
300 mL oral
PREPARATION
Finished product
INDICATION
Bowel marking
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Suspension of 300 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
EU
Lumirem®
for sale
spacer

• View the DATABASE results for 'Lumirem®' (5).Open this link in a new window

 
Further Reading:
  Basics:
ferumoxsil, oral suspension GastroMARK GastroMARK ®
MATERIAL SAFETY DATA SHEET
   by dailymed.nlm.nih.gov    
MRI Resources 
Spectroscopy - Spine MRI - Pathology - Mobile MRI Rental - Movies - Crystallography
 
Negative Oral Contrast AgentsForum -
related threadsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Categories of negative oral contrast agents:
Negative oral contrast media are usually based on superparamagnetic particles and act by inducing local field inhomogeneities, which results in shortening of both T1 and T2 relaxation times. Superparamagnetic contrast agents have predominant T2 weighted effects. Biphasic contrast media are agents that have different signal intensities on different sequences, depending on the concentration at which they are used.
Suitable materials for oral contrast agents should have little or no absorption by the stomach or intestines, complete excretion, no motion or susceptibility artifacts, affordability, and uniform marking of the gastrointestinal tract. Benefits of negative oral contrast agents are the reduction of ghosting artifacts caused by the lack of signal. Superparamagnetic iron oxides produce also in low concentrations a noticeable signal loss; but can generate susceptibility artifacts especially in gradient echo sequences. Perfluorochemicals do not dilute in the bowel because they are not miscible with water.
High cost, poor availability, and limited evaluations of side effects are possible disadvantages.
Negative oral contrast agents are used e.g., in MRCP, where the ingestion of 600-900 ml of SPIO cancels out the signal intensity of the lumen (in addition after the injection of a gadolinium-based contrast medium, the enhancement of the inflammatory tissues is clearer seen), and in MR abdominal imaging of Crohn's disease in combination with mannitol.
mri safety guidance
Contrast Guidance
Blueberry or pineapple juices are useable for examinations of the pancreas (MRCP, upper abdominal imaging) as cheep contrast agents, because of the content of magnetic substances (e.g. manganese).

See also Ferristene, Ferumoxsil, Oral Magnetic Particles, Gastrointestinal Imaging.
spacer

• View the DATABASE results for 'Negative Oral Contrast Agents' (7).Open this link in a new window

 
Further Reading:
  Basics:
Components of Oral Contrast Agent for Magnetic Resonance Imaging(.pdf)
   by www.ffcr.or.jp    
MRI Resources 
MRA - Calculation - Fluorescence - Musculoskeletal and Joint MRI - MRI Accidents - Mass Spectrometry
 
Superparamagnetic Iron OxideInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
(SPIO) Relatively new types of MRI contrast agents are superparamagnetic iron oxide-based colloids (median diameter greater than 50nm). These compounds consist of nonstoichiometric microcrystalline magnetite cores, which are coated with dextrans (in ferumoxide) or siloxanes (in ferumoxsil). After injection they accumulate in the reticuloendothelial system (RES) of the liver (Kupffer cells) and the spleen. At low doses circulating iron decreases the T1 time of blood, at higher doses predominates the T2* effect.
SPIO agents are much more effective in MR relaxation than paramagnetic agents. Since hepatic tumors either do not contain RES cells or their activity is reduced, the contrast between liver and lesion is improved. Superparamagnetic iron oxides cause noticeable shorter T2 relaxation times with signal loss in the targeted tissue (e.g., liver and spleen) with all standard pulse sequences. Magnetite, a mixture of FeO and Fe2O3, is one of the used iron oxides. FeO can be replaced by Fe3O4.
Use of these colloids as tissue specific contrast agents is now a well-established area of pharmaceutical development. Feridex®, Endorem™, GastroMARK®, Lumirem®, Sinerem®, Resovist® and more patents pending tell us that the last word in this area is not said.
Some remarkable points using SPIO:
A minimum delay of about 10 min. between injection (or infusion) and MR imaging, extends the examination time.
Cross-section flow void in narrow blood vessels may impede the differentiation from small liver lesions.
Aortic pulsation artifacts become more pronounced.


See also Superparamagnetism, Superparamagnetic Contrast Agents and Classifications, Characteristics, etc..
spacer

• View the DATABASE results for 'Superparamagnetic Iron Oxide' (32).Open this link in a new window


• View the NEWS results for 'Superparamagnetic Iron Oxide' (3).Open this link in a new window.
 
Further Reading:
  Basics:
IMAGE CONTRAST IN MRI(.pdf)
   by www.assaftal.com    
  News & More:
How to stop using gadolinium chelates for magnetic resonance imaging: clinical-translational experiences with ferumoxytol
Saturday, 5 February 2022   by www.ncbi.nlm.nih.gov    
Polysaccharide-Core Contrast Agent as Gadolinium Alternative for Vascular MR
Monday, 8 March 2021   by www.diagnosticimaging.com    
Poly (dopamine) coated superparamagnetic iron oxide nanocluster for noninvasive labeling, tracking, and targeted delivery of adipose tissue-derived stem cells
Tuesday, 5 January 2016   by www.nature.com    
Longitudinal MRI contrast enhanced monitoring of early tumour development with manganese chloride (MnCl2) and superparamagnetic iron oxide nanoparticles (SPIOs) in a CT1258 based in vivo model of prostate cancer
Wednesday, 11 July 2012   by www.biomedcentral.com    
MRI Resources 
Claustrophobia - Fluorescence - MRI Physics - MRI Centers - Pediatric and Fetal MRI - Contrast Agents
 
     1 - 5 (of 5)     
Result Pages : [1]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 16 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]