Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'bolus' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'bolus' found in 4 terms [] and 20 definitions []
1 - 5 (of 24)     next
Result Pages : [1]  [2 3 4 5]
Searchterm 'bolus' was also found in the following service: 
spacer
Forum  (5)  
 
Care Bolus
 
Using a care bolus ensures optimal contrast of arterial vessels in contrast enhanced MRA. The center of the k-space is measured as quickly as possible once the contrast agent reaches the region of interest.
spacer
 
• Share the entry 'Care Bolus':  Facebook  Twitter  LinkedIn  
MRI Resources 
Quality Advice - MR Myelography - Education - Databases - Pediatric and Fetal MRI - Health
 
Bolus Tracking
 
A method of tracking moving spins after tagging them (locally altering their magnetization). The moving spins are then imaged at some time after tagging to show where the bolus (the small tagged volume of spins) has moved in the imaging plane.
spacer

• View the DATABASE results for 'Bolus Tracking' (4).Open this link in a new window

 
Further Reading:
  Basics:
Contrast Bolus Timing and Scan Delay
2003   by www.med.nyu.edu    
Contrast MRI Best at Finding Liver Trouble - But Timing Matters
Sunday, 6 March 2011   by www.searchmedica.com    
MRI Resources 
Mobile MRI Rental - Spectroscopy - Jobs pool - MRI Technician and Technologist Career - Musculoskeletal and Joint MRI - NMR
 
Bolus Injection
 
A bolus is a rapid infusion of high dose contrast agent. Dynamic and accumulation phase imaging can be performed after bolus injection. Since the transit time of the bolus through the tissue is only a few seconds, high temporal resolution imaging can be required to obtain sequential images during the wash in and wash out of the contrast material and, therefore, resolve the first pass of the tracer.
For the same injected dose of contrast agent the injection rate (and, consequently, the total injected volume) modifies the bolus peak profile. Increasing the injection rate produces a sharpening of the peak (Cmax increase, Tmax decrease, peak length decrease). At a low injection rate, the first pass presents a plateau form. Substantial changes in the gadolinium concentrations during signal acquisition induce artifacts. Furthermore, the haemodynamic parameters (cardiac output, blood pressure) influence the bolus profile. The characteristics of gadolinium agents are favorable in the early bolus phase, whereas the advantages of large complexes (e.g. blood pool agents) and ultrasmall superparamagnetic iron oxide (USPIO) are most evident in the distribution phase.
 
Images, Movies, Sliders:
 Left Circumflex Ischemia First-pass Contrast Enhancement  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 Normal Lung Gd Perfusion MRI  Open this link in a new window
 
spacer

• View the DATABASE results for 'Bolus Injection' (9).Open this link in a new window

 
Further Reading:
  News & More:
Contrast Bolus Timing and Scan Delay
2003   by www.med.nyu.edu    
Searchterm 'bolus' was also found in the following service: 
spacer
Forum  (5)  
 
Automatic Bolus DetectionInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
Automatic bolus detection is used to trigger the begin of the MRI scan with the time the contrast agent reaches the region of interest. The acquisition process is started once the signal is increased in this region. There are similar methods used by the scanner manufacturer (see MRI Acronyms for Automatic Bolus Detection). After injection of the contrast agent the region of interest is monitored (e.g. with a spin echo or gradient echo sequence). When the signal increases the scan is automatically triggered or the operator is informed.

See also Abdominal Imaging, Bolus Injection, Fluoroscopic Triggering, Care Bolus, and Bolus Tracking.
spacer

• View the DATABASE results for 'Automatic Bolus Detection' (4).Open this link in a new window

 
Further Reading:
  Basics:
Fast Contrast Enhanced Imaging with Projection Reconstruction(.pdf)
   by ece.ut.ac.ir    
  News & More:
Abdominal MR angio: fast, reproducible, and safe
   by www.diagnosticimaging.com    
MRI Resources 
Pacemaker - Safety pool - Lung Imaging - Blood Flow Imaging - Mobile MRI - Liver Imaging
 
Contrast Enhanced Magnetic Resonance AngiographyInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:
 - MRA -
 
(CE MRA) Contrast enhanced MR angiography is based on the T1 values of blood, the surrounding tissue, and paramagnetic contrast agent.
T1-shortening contrast agents reduces the T1 value of the blood (approximately to 50 msec, shorter than that of the surrounding tissues) and allow the visualization of blood vessels, as the images are no longer dependent primarily on the inflow effect of the blood. Contrast enhanced MRA is performed with a short TR to have low signal (due to the longer T1) from the stationary tissue, short scan time to facilitate breath hold imaging, short TE to minimize T2* effects and a bolus injection of a sufficient dose of a gadolinium chelate.
Images of the region of interest are performed with 3D spoiled gradient echo pulse sequences. The enhancement is maximized by timing the contrast agent injection such that the period of maximum arterial concentration corresponds to the k-space acquisition. Different techniques are used to ensure optimal contrast of the arteries e.g., bolus timing, automatic bolus detection, bolus tracking, care bolus. A high resolution with near isotropic voxels and minimal pulsatility and misregistration artifacts should be striven for. The postprocessing with the maximum intensity projection (MIP) enables different views of the 3D data set.
Unlike conventional MRA techniques based on velocity dependent inflow or phase shift techniques, contrast enhanced MRA exploits the gadolinium induced T1-shortening effects. CE MRA reduces or eliminates most of the artifacts of time of flight angiography or phase contrast angiography. Advantages are the possibility of in plane imaging of the blood vessels, which allows to examine large parts in a short time and high resolution scans in one breath hold. CE MRA has found a wide acceptance in the clinical routine, caused by the advantages:
3D MRA can be acquired in any plane, which means that greater vessel coverage can be obtained at high resolution with fewer slices (aorta, peripheral vessels);
the possibility to perform a time resolved examination (similarly to conventional angiography);
no use of ionizing radiation; paramagnetic agents have a beneficial safety.
 
Images, Movies, Sliders:
 CE-MRA of the Carotid Arteries  Open this link in a new window
    
SlidersSliders Overview

 CE MRA of the Aorta  Open this link in a new window
    
SlidersSliders Overview

 CE-MRA of the Carotid Arteries Colored MIP  Open this link in a new window
    
SlidersSliders Overview

 
spacer

• View the DATABASE results for 'Contrast Enhanced Magnetic Resonance Angiography' (14).Open this link in a new window


• View the NEWS results for 'Contrast Enhanced Magnetic Resonance Angiography' (2).Open this link in a new window.
 
Further Reading:
  Basics:
Contrast-Enhanced MR Angiography(.pdf)
   by ric.uthscsa.edu    
CONTRAST ENHANCED MR ANGIOGRAPHY – PRINCIPLES, APPLICATIONS, TIPS AND PITFALLS(.pdf)
  News & More:
CONTRAST-ENHANCED MRA OF THE CAROTIDS(.pdf)
PERIPHERAL VASCULAR MAGNETIC RESONANCE ANGIOGRAPHY(.pdf)
CONTRAST ENHANCED MRI OF THE LIVER STATE-OF-THE-ART(.pdf)
MRI Resources 
Raman Spectroscopy - Education - Liver Imaging - Calculation - MRI Physics - Distributors
 
     1 - 5 (of 24)     next
Result Pages : [1]  [2 3 4 5]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 April 2024]
Terms of Use | Privacy Policy | Advertising