Central Lines
 
A part in the k-space filled with signals made by phase encoding gradients (weak) used for contrast-determination.
spacer
 
• Share the entry 'Central Lines':  Facebook  Twitter  LinkedIn  
MRI Resources 
Pediatric and Fetal MRI - Raman Spectroscopy - Musculoskeletal and Joint MRI - Manufacturers - Distributors - Contrast Enhanced MRI
 
Respiratory Compensation
 
Respiratory compensation reduces motion artifacts due to breathing. The approach is to reassign the echoes that are sensitive to respiratory motion in the central region of k-space. The outer lines of phase encoding normally contain the echoes where the motion from expiration is the greatest. The central portion of k-space will have encoded the echoes where inspiration and expiration are minimal. By a bellows device fixed to the abdomen, monitoring of the diaphragm excursion is possible. Respiratory compensation does not increase scan time with most systems.
An advantage of very fast sequences is the possibility of breath holding during the acquisition to eliminate motion artifacts. Breath hold is commonly used on most abdominal studies where images are acquired using gradient echo-based sequences during a brief inspiratory period (20-30 seconds). To enhance the breath holding endurance of the patient, connecting the patient to oxygen at a 1-liter flow rate via a nasal cannula has been shown to be helpful.
Also called PEAR, Respiratory Trigger, Respiratory Gating, PRIZE, FREEZE, Phase Reordering.

See also Phase Encoding Artifact Reduction, Respiratory Ordered Phase Encoding.
spacer

• View the DATABASE results for 'Respiratory Compensation' (4).Open this link in a new window

 
Further Reading:
  News & More:
Controlling patient's breathing makes cardiac MRI more accurate
Friday, 13 May 2016   by www.upi.com    
MRI Resources 
Online Books - Supplies - Contrast Enhanced MRI - Knee MRI - Equipment - MRI Centers
 
Lorentzian Line
 
Usual shape of the lines in a NMR spectrum, characterized by a central peak with long tails; proportional to 1/[(1/T2)2 + (f - fo)2], where f is frequency and fo is the frequency of the peak (i.e., central resonance frequency). A Lorentzian function is the Fourier transformation of a decaying exponential.
spacer

• View the DATABASE results for 'Lorentzian Line' (3).Open this link in a new window

Searchterm 'Central Lines' was also found in the following service: 
spacer
Forum  (1)  
 
     1 - 3 (of 3)     
Result Pages : [1]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 23 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]