Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Drug Information' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Drug Information' found in 0 term [] and 28 definitions []
previous     6 - 10 (of 28)     next
Result Pages : [1 2 3 4 5 6]
Searchterm 'Drug Information' was also found in the following services: 
spacer
News  (2)  Resources  (6)  
 
Dotarem®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Dotarem® is a paramagnetic ionic MRI contrast agent. Extracellular contrast agents like Dotarem®, can be bolus injected because of the relatively low rate of side effects. This contrast medium is useable to enhance signal intensity in magnetic resonance imaging for intracranial and spinal lesions with an abnormal blood brain barrier or abnormal vascularity, and in whole body imaging.

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.
Drug Information and Specification
NAME OF COMPOUND
DEVELOPER
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
r1=3.4, r2=4.8, B0=1.0T
PHARMACOKINETIC
Intravascular, extracellular, renal excretion
1350 mosm/kgH2O
CONCENTRATION
0.5 mol/L
DOSAGE
0.1 mmol/kg / 0.2mL/kg
PREPARATION
Finished product
INDICATION
Neuro/whole body
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Vials of 5, 10, 15, 20mL
Pre-filled syringes of 15 and 20 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
EU
for sale
France, Switzerland
Artirem®
for sale
Australia
for sale
spacer
 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
  News & More:
RSNA Statement on Gadolinium-Based MR Contrast Agents
Thursday, 1 February 2018   by www.rsna.org    
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
MRI Resources 
Anatomy - Open Directory Project - Mobile MRI - Shielding - Societies - Research Labs
 
Endorem™InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
A brand name for ferumoxide (same as Feridex®)
Endoremâ„¢ is a black to reddish-brown aqueous colloid of superparamagnetic iron oxide associated with dextran for intravenous administration as a MRI contrast medium for the detection of liver lesions that are associated with an alteration in the RES.
Endoremâ„¢ is taken up by macrophages, found only in healthy liver cells but not in most tumors. Tissues such as metastases, primary liver cancer, cysts and various benign tumors, adenomas and hyperplasia retain their native signal intensity, so the contrast between normal and abnormal tissue is increased.

See also Ferumoxide.
Drug Information and Specification
NAME OF COMPOUND
Dextran-coated ferumoxide, Ami-25
CENTRAL MOIETY
Fe2+/Fe3+
CONTRAST EFFECT
T2, predominantly negative enhancement
r1=40.0, r2=160, B0=0.47T
PHARMACOKINETIC
RES-directed
340 mosm/kgH2O
CONCENTRATION
11.2mg Fe/ml
DOSAGE
15 µmol Fe/kg
PREPARATION
Suspend in an isotonic glucose solution
INDICATION
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Ampoule of 8 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
EU
Brazil
Endorem™
for sale
Argentina
for sale
South Korea
for sale
Israel
for sale
spacer

• View the DATABASE results for 'Endorem™' (5).Open this link in a new window

 
Further Reading:
  News & More:
MAGNETIC RESONANCE IMAGING OF FOCAL LIVER LESIONS(.pdf)
2002
MRI Resources 
Safety Products - Blood Flow Imaging - Examinations - Open Directory Project - Resources - MRI Reimbursement
 
Eovist®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Eovist® (other brand name Primovist™) is a organ specific MRI contrast agent for the imaging, detection and characterization of liver conditions, including liver tumors, cysts, as well as other malignant and benign lesions. It is a water-soluble ethoxybenzyl derivative of Gd-DTPA. This compound is taken up by the hepatocytes (approximately 30% of the dose goes to the hepatocytes) and is equally excreted renal and biliary in humans. Excretion of Gd-EOB-DTPA in the bile may also permit visualization of both the gall bladder and the bile ducts.
Eovist® brightens the signal of T1 weighted MR images immediately after contrast administration. Dynamic and accumulation phase imaging can also be performed after bolus injection of Eovist®. The hepatocytes uptake will increase the signal intensity of normal liver parenchyma at 10 to 20 minutes after injection. This results in improved lesion-to-liver contrast because malignant tumors (metastases, the majority of hepatocellular carcinomas) do not contain either hepatocytes or their functioning is hampered.

WARNING: Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.

See also Drug Development and Approval Process USA, Contrast Medium, Hepatobiliary Contrast Agents, Tumor Specific Agents and Molecular Imaging.
Drug Information and Specification
NAME OF COMPOUND
Gadoxetic acid disodium, Gd-EOB-DTPA
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
Short T1-relaxation time
PHARMACOKINETIC
50% hepatobiliary, 50% renal excretion
884 mosm/kgH2O
CONCENTRATION
0.25 mol/L
DOSAGE
12,5 - 25 µmol/kg
PREPARATION
Finished product
INDICATION
Liver lesions
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
spacer

• View the DATABASE results for 'Eovist®' (4).Open this link in a new window

 
Further Reading:
  Basics:
HIGHLIGHTS OF PRESCRIBING INFORMATION
2008   by berlex.bayerhealthcare.com    
Searchterm 'Drug Information' was also found in the following services: 
spacer
News  (2)  Resources  (6)  
 
Feridex°InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
A brand name for ferumoxide (same as Endorem™)
Feridex® is a sterile aqueous colloid of superparamagnetic iron oxide associated with dextran for intravenous administration as a MRI contrast medium for the detection of liver lesions that are associated with an alteration in the RES.
Feridex® is taken up by macrophages, found only in healthy liver cells but not in most tumors. Tissues such as metastases, primary liver cancer, cysts and various benign tumors, adenomas and hyperplasia retain their native signal intensity, so the contrast between normal and abnormal tissue is increased. Feridex® is a black to reddish-brown aqueous colloid.
See also Ferumoxide.

In November 2008, AMAG Pharmaceuticals, Inc. decided to discontinue the manufacturing of Feridex.
Drug Information and Specification
NAME OF COMPOUND
Dextran-coated ferumoxide, Ami-25
CENTRAL MOIETY
Fe2+/Fe3+
CONTRAST EFFECT
T2, predominantly negative enhancement
r1=40.0, r2=160, B0=0.47T
PHARMACOKINETIC
RES-directed
340 mosm/kgH2O
CONCENTRATION
11.2mg Fe/ml
DOSAGE
15 µmol Fe/kg
PREPARATION
Suspend in an isotonic glucose solution
INDICATION
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Ampoule of 8 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
-
-
EU
Brazil
for sale ?
Argentina
for sale ?
South Korea
for sale ?
Israel
for sale ?
spacer

• View the DATABASE results for 'Feridex®' (9).Open this link in a new window

 
Further Reading:
  Basics:
AMAG Pharmaceuticals Inc. Q4 2008 Earnings Call Transcript
Friday, 27 February 2009   by seekingalpha.com    
Feridex Prescribing Information(.pdf)
   by berlex.bayerhealthcare.com    
  News & More:
MAGNETIC RESONANCE IMAGING OF FOCAL LIVER LESIONS(.pdf)
2002
MRI Resources 
Journals - Nerve Stimulator - MRI Centers - Universities - Pregnancy - MRI Accidents
 
FerriSeltz®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
A solution of ferric ammonium citrate (Geritol) used to enhance the delineation of the bowel. With T1 weighted magnetic resonance imaging (MRI) the predominantly positive enhancement helps to distinguish organs and tissues that are adjacent to the upper regions of the gastrointestinal tract. Product name found as both Ferriseltz® and FerriSeltz®.
Drug Information and Specification
NAME OF COMPOUND
DEVELOPER
CENTRAL MOIETY
Fe2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
Paramagnetic
PHARMACOKINETIC
Gastrointestinal
PREPARATION
Dissolve
INDICATION
Bowel marking
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Bags with powder
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
FerriSeltz®
for sale
spacer

• View the DATABASE results for 'FerriSeltz®' (4).Open this link in a new window

MRI Resources 
Stent - Functional MRI - Lung Imaging - Contrast Agents - MRI Physics - Implant and Prosthesis
 
previous      6 - 10 (of 28)     next
Result Pages : [1 2 3 4 5 6]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]