Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Drug Information' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Drug Information' found in 0 term [] and 28 definitions []
previous     26 - 28 (of 28)     
Result Pages : [1 2 3 4 5 6]
Searchterm 'Drug Information' was also found in the following services: 
spacer
News  (2)  Resources  (6)  
 
Sinerem®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Sinerem® is the brand name (same as Combidex®) for an ultrasmall superparamagnetic iron oxide (USPIO) to detect metastatic disease in lymph nodes. Metastatic nodes show less uptake of this MRI contrast agent, which results in less signal decrease and allows the differentiation of normal lymph nodes from normal-sized, metastatic nodes.
Lymph node imaging with Sinerem® is performed 24 to 36 hours after slow infusion. Normal lymph nodes turn black post contrast, namely on T2* weighted images. Metastatic lymph nodes remain unchanged in signal intensity.
Indication and Diseases: Cancer, Imaging for diagnosis, Lymphatic disorders.
See Ferumoxtran, and Classifications, Characteristics, etc.

Guerbet decided in 2007 to withdraw its Marketing Authorisation Application (MAA) for Sinerem.
Drug Information and Specification
NAME OF COMPOUND
Ferumoxtran, USPIO, AMI-227
CENTRAL MOIETY
Fe3+/Fe2+
CONTRAST EFFECT
r1=25, r2=160, B0=0.47T, r1=23.3, r2=48.9, B0=0.47T
PHARMACOKINETIC
Vascular, lymph v. hepatocyte (AG-USPIO)
CONCENTRATION
DOSAGE
2.6 mg Fe/kg
PREPARATION
Suspend in an isotonic glucose solution
INDICATION
MR angiography vascular, staging of RES-directed liver diseases, lymph nodes
DEVELOPMENT STAGE
-
DISTRIBUTOR
PRESENTATION
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
spacer
 
Further Reading:
  Basics:
The demise of Combidex - Sinerem
Wednesday, 24 March 2010   by www.wellsphere.com    
  News & More:
Ultrasmall Superparamagnetic Particles of Iron Oxide-enhanced in vivo MRI of human atherosclerotic plaques.(.pdf)
MRI Resources 
Devices - Non-English - MRI Physics - Corporations - MRI Technician and Technologist Career - MRI Accidents
 
Teslascan®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
(Mn-DPDP) This agent, mangafodipir trisodium, is a hepatocyte specific MRI contrast agent. Manganese is very toxic, so it has to be chelated and put in the form of a vitamin B6 analog, which is taken up by normal hepatocytes to some extent.
Teslascan® was developed in the early 1980's, went through clinical trials in the early 1990's, and was approved in 1997. One problem with assessing the efficacy of this agent is the fact that the phase III trials finished in the early 1990's, and the techniques used for MR today are very different from the techniques used almost a decade ago.
This contrast agent shortens the T1 relaxation time. On T1 weighted pictures it makes a normal liver look brighter. Since metastases, for example, do not generally take up this agent, the contrast between the enhancing liver and the non-enhancing lesions will increase on T1 weighted pictures. It does not have much effect on T2 weighted images.
Drug Information and Specification
NAME OF COMPOUND
Mangafodipir trisodium, Manganese dipyroxyl diphosphate, MN-DPDP
DEVELOPER
CENTRAL MOIETY
Mn2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
r1=2.3, r2=4.0, B0=1.0 T
PHARMACOKINETIC
Hepatobiliary, pancreatic, adrenal
290 mosm/kgH2O
CONCENTRATION
0.01 mmol/L
DOSAGE
5 µmol/kg, 0.5 ml/kg
PREPARATION
Finished product
INDICATION
Liver lesions
DEVELOPMENT STAGE
Approved
DISTRIBUTOR
See below
PRESENTATION
Vials of 100 ml
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
Teslascan®
for sale
EU
Teslascan®
for sale
spacer

• View the DATABASE results for 'Teslascan®' (4).Open this link in a new window

 
Further Reading:
  Basics:
EMEA - Teslascan - SCIENTIFIC DISCUSSION(.pdf)
   by www.emea.europa.eu    
  News & More:
Diagnosis and staging of pancreatic cancer: comparison of mangafodipir trisodium-enhanced MR imaging and contrast-enhanced helical hydro-CT.
2002
MAGNETIC RESONANCE IMAGING OF FOCAL LIVER LESIONS(.pdf)
2002
MRI Resources 
Stimulator pool - Portals - Bioinformatics - Homepages - Research Labs - Movies
 
Vasovistâ„¢InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Vasovistâ„¢ is an albumin-targeted intravascular contrast agent. It is indicated for contrast enhanced MR angiography (CE-MRA) for the visualization of abdominal or limb vessels in patients with suspected or known vascular disease. After IV injection, Vasovistâ„¢ binds reversibly to human albumin in plasma, which results in long-lasting increased relaxivity. Imaging from 5 to 50 min is possible. A small unbound portion is, by glomerular filtration, eliminated by the kidneys.
AngioMARK® was the formerly trade name and MS-325 the research name. Currently the phase III clinical trials are completed to determine its efficacy for peripheral vascular disease and coronary artery disease.
In the U.S., EPIX received an approvable letter from the U.S. Food and Drug Administration (FDA) for Vasovistâ„¢ in January 2005. In 2009, Epix Pharmaceuticals has sold the U.S., Canadian and Australian rights for its blood pool agent (now named ABLAVARâ„¢), to Lantheus Medical Imaging, Inc..

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or the liver transplantation period.

See also MRI Safety.
Drug Information and Specification
NAME OF COMPOUND
Diphenylcyclohexyl phosphodiester-Gd-DTPA, gadofosveset trisodium, MS-325
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, predominantly positive enhancement
20-45 mmol-1sec-1, Bo=0,47T
PHARMACOKINETIC
Intravascular, short elimination half life
825 mOsmol/kg H2O
CONCENTRATION
244 mg/mL, 0.25mmol/mL
DOSAGE
0.12 mL/kg, 0.03 mmol/kg
PREPARATION
ready to use
DEVELOPMENT STAGE
approved
DISTRIBUTOR
See below
PRESENTATION
10 mL vials
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
EU
Vasovistâ„¢
?
?
North America, Australia
for sale
spacer

• View the DATABASE results for 'Vasovist™' (7).Open this link in a new window

 
Further Reading:
  Basics:
EPIX Medical's new multimedia Web site features AngioMARK images in 3D
Friday, 5 March 1999
MRI technology combined with contrast agent optimizes diagnosis of cardiovascular disease
1999
Searchterm 'Drug Information' was also found in the following services: 
spacer
News  (2)  Resources  (6)  
 
previous      26 - 28 (of 28)     
Result Pages : [1 2 3 4 5 6]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]