| Info Sheets |
| | | | | | | | | | | | | | | | | | | | | | | | |
| Out- side |
| | | | |
|
| | | 'Lantheus Medical Imaging, Inc.' | |
Result : Searchterm 'Lantheus Medical Imaging, Inc.' found in 1 term [] and 2 definitions []
| 1 - 3 (of 3) Result Pages : [1] | | | | Searchterm 'Lantheus Medical Imaging, Inc.' was also found in the following services: | | | | |
| | |
Lantheus Medical Imaging, Inc. | |
| |
|
MRI Contrast Agents:
Contact Information
MAIL
Lantheus Medical Imaging
Bldg. 200-2, 331 Treble Cove Rd.
N. Billerica, MA 01862
USA
| | | | | • Share the entry 'Lantheus Medical Imaging, Inc.': | | | • View the NEWS results for 'Lantheus Medical Imaging, Inc.' (5).
| | | | |
| | | Searchterm 'Lantheus Medical Imaging, Inc.' was also found in the following service: | | | | |
| | |
| |
|
ABLAVAR™ (formerly named Vasovist™) is a blood pool agent for magnetic resonance angiography ( MRA), which opens new medical imaging possibilities in the evaluation of aortoiliac occlusive disease (AIOD) in patients with suspected peripheral vascular disease.
ABLAVAR™ binds reversibly to blood albumin, providing imaging with high spatial resolution up to 1 hour after injection, due to its high relaxivity and to the long lasting increased signal intensity of blood.
As with other contrast media: the possibility of serious or life-threatening anaphylactic or anaphylactoid reactions, including cardiovascular, respiratory and/or cutaneous manifestations, should always be considered.
WARNING: NEPHROGENIC SYSTEMIC FIBROSIS
Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m 2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.
See also Cardiovascular Imaging, Adverse Reaction, Molecular Imaging, and MRI Safety.
Drug Information and Specification
NAME OF COMPOUND
Diphenylcyclohexyl phosphodiester-Gd-DTPA, gadofosveset trisodium, MS-325
T1, predominantly positive enhancement
20-45 mmol-1sec-1, Bo=0,47T
PHARMACOKINETIC
Intravascular
CONCENTRATION
244 mg/mL, 0.25mmol/mL
DOSAGE
0.12 mL/kg, 0.03 mmol/kg
DEVELOPMENT STAGE
FDA approved
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING
PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT STAGE
DISTRIBUTOR
USA, Canada, Australia
ABLAVAR™
Approved
| | | | • View the DATABASE results for 'ABLAVAR™' (3).
| | | • View the NEWS results for 'ABLAVAR™' (1).
| | | | Further Reading: | | Basics:
|
|
News & More:
| |
| |
| | | | | |
| |
|
Vasovist™ is an albumin-targeted intravascular contrast agent. It is indicated for contrast enhanced MR angiography (CE-MRA) for the visualization of abdominal or limb vessels in patients with suspected or known vascular disease. After IV injection, Vasovist™ binds reversibly to human albumin in plasma, which results in long-lasting increased relaxivity. Imaging from 5 to 50 min is possible. A small unbound portion is, by glomerular filtration, eliminated by the kidneys.
AngioMARK® was the formerly trade name and MS-325 the research name. Currently the phase III clinical trials are completed to determine its efficacy for peripheral vascular disease and coronary artery disease.
In the U.S., EPIX received an approvable letter from the U.S. Food and Drug Administration (FDA) for Vasovist™ in January 2005. In 2009, Epix Pharmaceuticals has sold the U.S., Canadian and Australian rights for its blood pool agent (now named ABLAVAR™), to Lantheus Medical Imaging, Inc..
WARNING: NEPHROGENIC SYSTEMIC FIBROSIS
Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m 2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or the liver transplantation period.
See also MRI Safety.
Drug Information and Specification NAME OF COMPOUND Diphenylcyclohexyl phosphodiester-Gd-DTPA, gadofosveset trisodium, MS-325 T1, predominantly positive enhancement 20-45 mmol-1sec-1, Bo=0,47T PHARMACOKINETIC Intravascular, short elimination half life CONCENTRATION 244 mg/mL, 0.25mmol/mL DOSAGE 0.12 mL/kg, 0.03 mmol/kg DEVELOPMENT STAGE approved DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information TERRITORY TRADE NAME DEVELOPMENT STAGE DISTRIBUTOR North America, Australia for sale | | | | • View the DATABASE results for 'Vasovist™' (7).
| | | | Further Reading: | Basics:
|
|
| |
| | | Searchterm 'Lantheus Medical Imaging, Inc.' was also found in the following services: | | | | |
| |
| |
| | 1 - 3 (of 3) Result Pages : [1] |
| |
|
| |