Jobs pool - Patient Information - - Hospitals - MR Guided Interventions - Homepages
 
Magnetic Resonance CholangiopancreaticographyMRI Resource Directory:
 - MRCP -
 
(MRCP) This MR imaging technique takes advantage of the high signal intensity of body fluids and acquires heavy T2 weighted images of the gall bladder, the pancreas and parts of the liver. Due to the T2 weighting, the liver and other solid parenchyma are signal suppressed and only fluid-filled structures in addition to the gall bladder, the bile and pancreatic ducts retain important signal intensity. Hepatobiliary contrast agents (e.g. Gadoxetic Acid, CMC 001) can be useful for enhancement of the bile ducts and better imaging of the biliary tract.
A 2D cholangiogram, often only one thick slice (a volume with a thickness of 4 - 8 cm, mostly coronal planned) or 5 - 6 radial placed slices, shows a view like single slices. If a 3D acquisition is used, the postprocessing function maximum intensity projection (MIP) can show reconstructions from multiple sides.
Radiology-tip.comradBiliary Contrast Agents
spacer
Medical-Ultrasound-Imaging.comGallbladder Ultrasound
spacer
 
Further Reading:
  News & More:
Perspectum and Nuance Collaborate to Scale Access to AI-Enabled Integrated Digital Care Platforms to Improve Patient Care for Metabolic Disease
Friday, 9 December 2022   by www.itnonline.com    
MRI Resources 
Colonography - Claustrophobia - Resources - Quality Advice - Abdominal Imaging - Liver Imaging
 
Motion Probing Gradient
 
Many MR imaging techniques using Motion Probing Gradients (MPG's) such as Spin Echo (SE), Stimulated Echo (STE), Rapid Acquisition with Relaxation Enhancement (RARE), Turbo-SE, and SE-EPI (Echo Planar Imaging for Spin echo acquisition), Spiral imaging, and Projection reconstruction including PROPELLER are applicable to DWI. In diffusion weighted imaging, 2 MPG's are required. The MPG's are put symmetrically into both sides of a 180° or 90° RF pulse to change the direction of the magnetized spin in the X-Y plane for spin echo or stimulated echo acquisition.
spacer

• View the DATABASE results for 'Motion Probing Gradient' (2).Open this link in a new window

 
Further Reading:
  Basics:
Diffusion Imaging: From Basic Physics to Practical Imaging
1999   by ej.rsna.org    
  News & More:
Motion Compensation in MR Imaging
   by ccn.ucla.edu    
MRI Resources 
Blood Flow Imaging - MRI Training Courses - Journals - Corporations - Quality Advice - Safety Training
 
Filtered Back Projection
 
Mathematical technique used in projection-reconstruction imaging to create images from a set of multiple projection profiles. The projection profiles are back projected to produce a two (or three) dimensional image. The projection profiles are processed by convolving them with a suitable mathematical function (filtered) prior to back projecting them, in order to improve the image. Widely used in conventional computed tomography (CT).
spacer

• View the DATABASE results for 'Filtered Back Projection' (2).Open this link in a new window

 
Further Reading:
  Basics:
Tomographic Image Reconstruction
   by www.aapm.org    
MRI Resources 
Contrast Agents - Manufacturers - Safety Training - Anatomy - MRI Centers - Absorption and Emission
 
Medical Imaging
 
The definition of imaging is the visual representation of an object. Medical imaging began after the discovery of x-rays by Konrad Roentgen 1896. The first fifty years of radiological imaging, pictures have been created by focusing x-rays on the examined body part and direct depiction onto a single piece of film inside a special cassette. The next development involved the use of fluorescent screens and special glasses to see x-ray images in real time.
A major development was the application of contrast agents for a better image contrast and organ visualization. In the 1950s, first nuclear medicine studies showed the up-take of very low-level radioactive chemicals in organs, using special gamma cameras. This medical imaging technology allows information of biologic processes in vivo. Today, PET and SPECT play an important role in both clinical research and diagnosis of biochemical and physiologic processes. In 1955, the first x-ray image intensifier allowed the pick up and display of x-ray movies.
In the 1960s, the principals of sonar were applied to diagnostic imaging. Ultrasonic waves generated by a quartz crystal are reflected at the interfaces between different tissues, received by the ultrasound machine, and turned into pictures with the use of computers and reconstruction software. Ultrasound imaging is an important diagnostic tool, and there are great opportunities for its further development. Looking into the future, the grand challenges include targeted contrast agents, real-time 3D ultrasound imaging, and molecular imaging.
Digital imaging techniques were implemented in the 1970s into conventional fluoroscopic image intensifier and by Godfrey Hounsfield with the first computed tomography. Digital images are electronic snapshots sampled and mapped as a grid of dots or pixels. The introduction of x-ray CT revolutionised medical imaging with cross sectional images of the human body and high contrast between different types of soft tissue. These developments were made possible by analog to digital converters and computers. The multislice spiral CT technology has expands the clinical applications dramatically.
The first MRI devices were tested on clinical patients in 1980. The spread of CT machines is the spur to the rapid development of MRI imaging and the introduction of tomographic imaging techniques into diagnostic nuclear medicine. With technological improvements including higher field strength, more open MRI magnets, faster gradient systems, and novel data-acquisition techniques, MRI is a real-time interactive imaging modality that provides both detailed structural and functional information of the body.
Today, imaging in medicine has advanced to a stage that was inconceivable 100 years ago, with growing medical imaging modalities:
Single photon emission computed tomography (SPECT)
Positron emission tomography (PET)

All this type of scans are an integral part of modern healthcare. Because of the rapid development of digital imaging modalities, the increasing need for an efficient management leads to the widening of radiology information systems (RIS) and archival of images in digital form in picture archiving and communication systems (PACS). In telemedicine, healthcare professionals are linked over a computer network. Using cutting-edge computing and communications technologies, in videoconferences, where audio and visual images are transmitted in real time, medical images of MRI scans, x-ray examinations, CT scans and other pictures are shareable.
See also Hybrid Imaging.

See also the related poll results: 'In 2010 your scanner will probably work with a field strength of', 'MRI will have replaced 50% of x-ray exams by'
Radiology-tip.comradDiagnostic Imaging
spacer
Medical-Ultrasound-Imaging.comMedical Imaging
spacer

• View the DATABASE results for 'Medical Imaging' (20).Open this link in a new window


• View the NEWS results for 'Medical Imaging' (81).Open this link in a new window.
 
Further Reading:
  Basics:
Image Characteristics and Quality
   by www.sprawls.org    
Multimodal Nanoparticles for Quantitative Imaging(.pdf)
Tuesday, 13 December 2011   by alexandria.tue.nl    
Medical imaging shows cost control problem
Tuesday, 6 November 2012   by www.mysanantonio.com    
  News & More:
iMPI: An Exploration of Post-Launch Advancements
Friday, 29 September 2023   by www.diagnosticimaging.com    
Advances in medical imaging enable visualization of white matter tracts in fetuses
Wednesday, 12 May 2021   by www.eurekalert.or    
Positron Emission Tomographic Imaging in Stroke
Monday, 28 December 2015   by www.ncbi.nlm.nih.gov    
Multiparametric MRI for Detecting Prostate Cancer
Wednesday, 17 December 2014   by www.onclive.com    
Combination of MRI and PET imaging techniques can prevent second breast biopsy
Sunday, 29 June 2014   by www.news-medical.net    
3D-DOCTOR Tutorial
   by www.ablesw.com    
MRI Resources 
Used and Refurbished MRI Equipment - Journals - Manufacturers - Most Wanted - MRI Accidents - Crystallography
 
ViewForum -
related threads
 
The ensemble of raw data points collected during the signal readout. For example, during Cartesian sampling, normally used to refer to data collected with a fixed value of the phase encoding gradient. Also referred to as one line of k-space. In projection reconstruction, the line is radial oriented, while in spiral imaging, it is a spiral.
spacer

• View the DATABASE results for 'View' (160).Open this link in a new window


• View the NEWS results for 'View' (20).Open this link in a new window.
 
Further Reading:
  Basics:
Image Characteristics and Quality
   by www.sprawls.org    
MRI Resources 
Distributors - MR Myelography - Contrast Agents - PACS - RIS - Implant and Prosthesis pool
 
previous      6 - 10 (of 10)     
Result Pages : [1]  [2]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]