Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Quench' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Quench' found in 2 terms [] and 3 definitions []
1 - 5 (of 5)     
Result Pages : [1]
Searchterm 'Quench' was also found in the following service: 
spacer
Forum  (3)  
 
Quench
 
Quenching is the cryogen boil off (liquid helium) which is used to cool the superconducting magnet coils of high field MRI systems. This results in a loss of superconductivity in the magnet, in a rapid increase in the resistivity of the magnet, which generates heat that results in further evaporation of the cryogen.
mri safety guidance
MRI Safety Guidance
A quench can cause total magnet failure and should be avoided.
spacer
 
• Share the entry 'Quench':  Facebook  Twitter  LinkedIn  
 
• Related Searches:
    • Superconducting Magnet
    • Superconductor
    • Cryogen
    • Helium
    • Quenching
 
Further Reading:
  Basics:
Cryogenic Liquids and their Hazards
   by www.ccohs.ca    
MRI Resources 
Process Analysis - Research Labs - Calculation - Mobile MRI Rental - Stent - Safety Training
 
Quenching
 
A quench is the rapid helium evaporation and the loss of superconductivity of the current-carrying coil that may occur unexpectedly, or from pressing the emergency button in a superconducting magnet. As the superconductive magnet becomes resistive, heat will be released that can result in boiling of liquid helium in the cryostat. This may present a hazard if not properly planned for.
The evaporated coolant requires emergency venting systems to protect patients and operators. Quenching can cause total magnet failure and cannot be stopped. MRI systems are designed such that all of the escaping cryogenic gas is directed out of the building (quench pipe through the roof or the wall). In the event of a burst of the tank (possible in the case of an accident) or a blockage of the pipes, the helium gas will be forced into the scanner room, giving rise to a large white cloud of chilled gas. Under such circumstances it is essential that the scanner room is evacuated, also caused by the displacement of oxygen, which under extreme conditions could lead to asphyxiation. The force of quenching can be strong enough to destroy the walls of the scanner room or the MRI equipment.
spacer

• View the DATABASE results for 'Quenching' (5).Open this link in a new window

MRI Resources 
Nerve Stimulator - Devices - MRI Centers - Libraries - MRA - Homepages
 
Helium
 
The element helium (He) was discovered 1868 when P.J.C. Janssen and N. Lockyer detected a new line in the solar spectrum during the solar eclipse. Lockyer and E. Frankland suggested the name helium (Gr. Helios, the sun) for the new element. In 1895, helium was discovered in the uranium mineral cleveite and in 1907 it was found out that alpha particles are helium nuclei.
Properties: Helium belongs to the noble gases, is colorless, odorless, and occurs in two naturally isotopes, helium 3 and helium 4. As an inert gas, helium does not react chemically largely and don't burns. Helium 4 makes up over 99% of naturally occurring helium atoms. Helium is extracted from natural gas e.g. present in various radioactive minerals as a decay product. Deposits and sources are in the USA, Poland, the USSR, and a few in India. The rare deposits and increased consumption lead to a shortage of this gas.
K. Onnes worked for many years to liquefy helium, which persisted as a gas to the lowest temperature. Helium does not freeze at atmospheric pressure. The density of helium vapor at his boiling point of 4.2 Kelvin is very high, with the vapor expanding greatly when heated to room temperature. Nb, Tc, Pb, La, V, and Ta are superconductors at liquid helium temperature. Liquid helium is commonly used as a cryogen for superconducting magnets. A rapid evaporation of the cryogen is named Quench. See also Quenching.
mri safety guidance
MRI Safety Guidance
Cryogenic liquids and their associated cold vapors can produce effects on the skin similar to a thermal burn and can cause frostbite. Prolonged breathing of extremely cold gases may damage the lungs and in absence of enough air or oxygen, asphyxiation and death can occur. Unprotected skin can stick to very cold metal (e.g. cooled by liquid helium) and then tear when pulled away.
spacer

• View the DATABASE results for 'Helium' (43).Open this link in a new window


• View the NEWS results for 'Helium' (2).Open this link in a new window.
 
Further Reading:
  Basics:
Superfluid helium-4
Monday, 12 February 2018   by en.wikipedia.org    
Cryogenic Liquids and their Hazards
   by www.ccohs.ca    
Liquid Helium
   by hyperphysics.phy-astr.gsu.edu    
  News & More:
Renergen surges after xceptional™ helium concentration reports
Monday, 29 March 2021   by www.businesslive.co.za    
Not just balloons: Helium shortage may deflate MRIs, airbags and research
Friday, 3 May 2019   by eu.usatoday.com    
Liquid helium, the lifeblood of MRI machines
Tuesday, 5 March 2019   by www.gasworld.com    
Preclinical Imaging Systems Reduce Environmental Impact
Monday, 4 November 2019   by www.itnonline.com    
Huge newfound deposit of helium will keep MRI scanners running
Monday, 27 June 2016   by www.newscientist.com    
Philips launches Ingenia Ambition X 1.5T MR with industry-first fully sealed magnet for more productive, helium-free operations
Tuesday, 11 September 2018   by www.philips.com    
Tech firms, medical research threatened by helium shortage
Thursday, 19 September 2013   by www.livemint.com    
How 9/11 Made The Global Helium Shortage Worse
Thursday, 3 July 2014   by www.popsci.com    
Cooling MRI magnets without a continuous supply of scarce helium
Tuesday, 13 August 2013   by www.wired.co.uk    
Searchterm 'Quench' was also found in the following service: 
spacer
Forum  (3)  
 
Superconducting Magnet
 
Superconducting magnets are electromagnets that are partially built from superconducting materials and therefore reach much higher magnetic field intensity.
The coil windings of superconducting magnets are made of wires of a type 2 superconductor (mostly used is niobium-titanium - up to 15 Tesla the critical temperature is less then 10 Kelvin). These coils have no resistance when operated at temperatures near absolute zero (-273.15°C, -459°F, 0 K).
Liquid helium (4.2 K) is commonly used as a coolant (sometimes in addition with a second cryogen liquid nitrogen as an intermediate thermal shield to reduce the boil-off rate of liquid helium), which consequently conclude refilling (intervals: liquid helium ~ 3 month, liquid nitrogen ~ 2 weeks). There are cryogen-free superconducting magnets with a closed-cycle refrigerating system at the horizon. Superconducting magnets typically exhibit field strengths of greater than 0.5 T, operate clinically up to 3 T, and have a horizontal field orientation, which makes them prone to missile effects without significant magnetic shielding.
See also Quenching.

See also the related poll result: 'In 2010 your scanner will probably work with a field strength of'
spacer

• View the DATABASE results for 'Superconducting Magnet' (15).Open this link in a new window


• View the NEWS results for 'Superconducting Magnet' (3).Open this link in a new window.
 
Further Reading:
  Basics:
Superconducting Magnets
   by hyperphysics.phy-astr.gsu.edu    
Magnetic Field of the Strongest Magnet
2003   by hypertextbook.com    
  News & More:
A hot time for cold superconductors
Tuesday, 9 December 2003   by www.brightsurf.com    
MRI Resources 
Shoulder MRI - Cochlear Implant - Cardiovascular Imaging - Spectroscopy pool - RIS - Artifacts
 
Superconductor
 
A substance whose electrical resistance essentially disappears at temperatures near absolute zero. A perfect superconductor can carry an electrical current without losses. Nb, Tc, Pb, La, V, and Ta are superconductors at liquid helium temperature. A commonly used superconductor in MRI system magnets is niobium-titanium, embedded in a copper matrix to help protect the superconductor from quenching.
spacer

• View the DATABASE results for 'Superconductor' (4).Open this link in a new window


• View the NEWS results for 'Superconductor' (3).Open this link in a new window.
 
Further Reading:
  Basics:
Superconducting Magnets
   by hyperphysics.phy-astr.gsu.edu    
A step nearer to understanding superconductivity
Thursday, 7 June 2007   by www.brightsurf.com    
Linear Collider Final FocusMagnet Construction
   by www.bnl.gov    
  News & More:
Supercurrent goes to the edge
Thursday, 11 June 2020   by physicsworld.com    
New Princeton study takes superconductivity to the edge
Thursday, 30 April 2020   by www.princeton.edu    
Global Superconductors Industry
Monday, 27 February 2017   by www.prnewswire.com    
Application of high-temperature superconductor yields world's highest magnetic field
Wednesday, 1 July 2015   by phys.org    
MRI Resources 
Universities - Movies - Lung Imaging - Jobs pool - Contrast Agents - MRA
 
     1 - 5 (of 5)     
Result Pages : [1]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]