Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Resolution Element' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Resolution Element' found in 1 term [] and 1 definition [], (+ 10 Boolean[] results
previous     11 - 12 (of 12)     
Result Pages : [1]  [2 3]
MRI Resources 
MRI Training Courses - Jobs pool - Pacemaker - Quality Advice - Education pool - Spine MRI
 
Phased Array CoilInfoSheet: - Coils - 
Intro, 
Overview, 
etc.MRI Resource Directory:
 - Coils -
 
The phased array coils operate typically as receive only coils. In that case, the in the MRI device implemented body coil act as the transmitter and sends the radio frequency energy to generate the excitation pulses. State-of-the-art array coil systems include the use of 4 (up to 32) coils with separate receivers. This method is often referred to as a phased array system, although the signals are not added such that the signal phase information is included. The use of phased array coils allows the decreasing of the number of signal averages, which shortens the scan time by high SNR and resolution.
High-sensitivity RF surface coils and digital processing algorithms have been developed that speed up image acquisition and reconstruction during the MRI scan.
Fast parallel imaging techniques, for example sensitivity encoding (SENSE), 'Partially Parallel Imaging with Localized Sensitivity' (PILS), Simultaneous Acquisition of Spatial Harmonics (SMASH) or Array Spatial Sensitivity Encoding Technique (ASSET) use phased array multichannel coils to further improve spatial and temporal resolution. The sensitivity profile of a phased array coil element is measured by a separate low resolution 3D acquisition over the entire field of view in the case of a SENSE acquisition. For an mSENSE measurement, a self-calibration acquires some of the missing lines in the center of the k-space.
Also called linear array coil or synergy surface coil.

See also the related poll result: '3rd party coils are better than the original manufacturer coils'
spacer
 
• Related Searches:
    • Transmitter
    • Parallel Imaging Technique
    • Receiver
    • Signal to Noise Ratio
    • Array Coil
 
Further Reading:
  Basics:
Coil Arrays for Parallel MRI: Introduction and Overview.
   by www.mr.ethz.ch    
Searchterm 'Resolution Element' was also found in the following service: 
spacer
Radiology  (2) Open this link in a new window
Spatial Resolution
 
The smallest distance between two points in the object that can be distinguished as separate details in the image, generally indicated as a length or a number of black and white line pairs per mm (lp/mm).
The specific criterion for resolution to be used, depends on the type of test used (e.g., bar pattern or contrast-detail phantom). As the ability to separate or detect objects depends on their contrast and the noise, and the different MR parameters of objects will affect image contrast differently for different imaging techniques, care must be taken in comparing the results of resolution phantom tests of different machines and no single simple measure of resolution can be specified.
The resolution may be an isotropic one. The resolution may be larger than the size corresponding to the discrete image element (pixel), although it cannot be smaller.
 
Images, Movies, Sliders:
 MRI - Anatomic Imaging of the Ankle 1  Open this link in a new window
    
SlidersSliders Overview

 Anatomic MRI of the Knee 1  Open this link in a new window
    
SlidersSliders Overview

 
spacer

• View the DATABASE results for 'Spatial Resolution' (79).Open this link in a new window

 
Further Reading:
  Basics:
Faster speed, better spatial resolution lead 3T benefits
   by sipi.usc.edu    
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Sunday, 1 August 2004   by www.ajronline.org    
  News & More:
New Paradigm for Nanoscale Resolution MRI Experimentally Achieved
Friday, 27 September 2013   by www.sciencedaily.com    
3-D Virus Imaging wth Magnetic Resonance Force Microscopy
Wednesday, 14 January 2009   by www.medgadget.com    
MRI Resources 
MRI Accidents - Breast Implant - Mass Spectrometry - Equipment - Sequences - Pathology
 
previous      11 - 12 (of 12)     
Result Pages : [1]  [2 3]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 3 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]