Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Safety Guidance' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Safety Guidance' found in 0 term [] and 27 definitions []
previous     21 - 25 (of 27)     next
Result Pages : [1 2 3 4 5 6]
Searchterm 'Safety Guidance' was also found in the following service: 
spacer
News  (4)  
 
ProsthesesMRI Resource Directory:
 - Safety -
 
Generally, joint and limb prostheses presents low MRI risks of heating and magnetic attraction, but image artifacts can be caused by them.
mri safety guidance
MRI Safety Guidance
If possible, prostheses should be removed prior to the MR examination. Risks are depending on the field strength, the used material, the shape and the length of prostheses. A material like titanium alloy is safely. The use of a low to mid field MRI device presents also a high safety.
spacer
• For this and other aspects of MRI safety see our InfoSheet about MRI Safety.
• Patient-related information is collected in our MRI Patient Information.

MRI Safety Resources 
Breast Implant - Claustrophobia - Cochlear Implant - Stent - Stimulator pool
 
Prosthetic Heart ValvesMRI Resource Directory:
 - Safety -
 
The interactions between the most tested heart valve prostheses and the magnetic field of MRI devices are of no significance. However, there are many different types of heart valve prostheses and in the particular case their MRI safety should be checked.
mri safety guidance
MRI Safety Guidance
Prosthetic heart valves, depending on the type and the material, are not necessarily considered to be dangerous in fields up to 3T. Patients should not undergo high field MRI examinations if valve dehiscence is clinically suspected.
spacer

• View the DATABASE results for 'Prosthetic Heart Valves' (2).Open this link in a new window

 
Further Reading:
  Basics:
Prosthetic Heart Valves: Evaluation of Magnetic Field Interactions, Heating, and Artifacts at 1.5 T
2000   by www.imrser.org    
  News & More:
Guidelines for the Management of Patients with Heart Valve Prostheses and Annuloplasty Rings Referred for MRI Procedures
Tuesday, 1 January 2019   by www.ismrm.org    
Codman Neuro develops new MRI-resistant programmable valve for treatment of hydrocephalus
Tuesday, 22 September 2015   by www.news-medical.net    
MRI Resources 
Crystallography - Artifacts - Colonography - Stimulator pool - DICOM - MRI Technician and Technologist Jobs
 
Quench
 
Quenching is the cryogen boil off (liquid helium) which is used to cool the superconducting magnet coils of high field MRI systems. This results in a loss of superconductivity in the magnet, in a rapid increase in the resistivity of the magnet, which generates heat that results in further evaporation of the cryogen.
mri safety guidance
MRI Safety Guidance
A quench can cause total magnet failure and should be avoided.
spacer

• View the DATABASE results for 'Quench' (5).Open this link in a new window

 
Further Reading:
  Basics:
Cryogenic Liquids and their Hazards
   by www.ccohs.ca    
Searchterm 'Safety Guidance' was also found in the following service: 
spacer
News  (4)  
 
Skin Depth
 
Time-dependent electromagnetic fields are significantly attenuated by conducting media (including the human body); the skin depth gives a measure of the average depth of penetration of the RF field. A high power frequency tunable RF source can be rapidly switched on and off. This produces a large RF field perpendicular to the magnetic field. This RF field is focused by the body coil. The RF source and coils must be tunable in both frequency and impedance to 'match the impedance' of the patient's body.
mri safety guidance
MRI Safety Guidance
The skin depth may be a limiting factor in MR imaging at very high frequencies (high magnetic fields). The skin depth also affects the Q of the coils.
spacer
 
Further Reading:
  News & More:
Magnetic resonance-guided motorized transcranial ultrasound system for blood-brain barrier permeabilization along arbitrary trajectories in rodents
Thursday, 24 December 2015   by www.ncbi.nlm.nih.gov    
MRI Resources 
RIS - Jobs - Abdominal Imaging - Libraries - MRI Reimbursement - Portals
 
Skin PatchesMRI Resource Directory:
 - Safety -
 
Pharmaceutical products in transdermal skin patches may cause burns due to the absorption of RF energy.
mri safety guidance
MRI Safety Guidance
Such patches must be removed prior to MR examinations.
spacer
MRI Resources 
Veterinary MRI - Brain MRI - Supplies - Safety pool - MRI Centers - Used and Refurbished MRI Equipment
 
previous      21 - 25 (of 27)     next
Result Pages : [1 2 3 4 5 6]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]