Segmented K-Space Data Acquisition
 
A set of k-space lines collected in a specified order but not constituting a complete coverage of k-space, thus can be used in conjunction with all ultrafast MRI techniques. Several segmental acquisitions may need to be run for complete coverage of k-space. If these lines are recorded for a single rather than multiple images, imaging time can be shortened considerably maintaining an acceptable temporal resolution.
For example, rapidly acquiring eight k-space lines per segment after each trigger until 128 lines of k-space are acquired in 16 triggers, thus makes image acquisition of multiple cardiac phases or anatomical slices possible in a breath-hold.
spacer
MRI Resources 
Sequences - Mobile MRI - Libraries - Implant and Prosthesis pool - Stent - Guidance
 
Sensitivity EncodingInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(SENSE) A MRI technique for relevant scan time reduction. The spatial information related to the coils of a receiver array are utilized for reducing conventional Fourier encoding. In principle, SENSE can be applied to any imaging sequence and k-space trajectories. However, it is particularly feasible for Cartesian sampling schemes. In 2D Fourier imaging with common Cartesian sampling of k-space sensitivity encoding by means of a receiver array enables to reduce the number of Fourier encoding steps.
SENSE reconstruction without artifacts relies on accurate knowledge of the individual coil sensitivities. For sensitivity assessment, low-resolution, fully Fourier-encoded reference images are required, obtained with each array element and with a body coil.
The major negative point of parallel imaging techniques is that they diminish SNR in proportion to the numbers of reduction factors. R is the factor by which the number of k-space samples is reduced. In standard Fourier imaging reducing the sampling density results in the reduction of the FOV, causing aliasing. In fact, SENSE reconstruction in the Cartesian case is efficiently performed by first creating one such aliased image for each array element using discrete Fourier transformation (DFT).
The next step then is to create a full-FOV image from the set of intermediate images. To achieve this one must undo the signal superposition underlying the fold-over effect. That is, for each pixel in the reduced FOV the signal contributions from a number of positions in the full FOV need to be separated. These positions form a Cartesian grid corresponding to the size of the reduced FOV.
The advantages are especially true for contrast-enhanced MR imaging such as dynamic liver MRI (liver imaging) , 3 dimensional magnetic resonance angiography (3D MRA), and magnetic resonance cholangiopancreaticography (MRCP).
The excellent scan speed of SENSE allows for acquisition of two separate sets of hepatic MR images within the time regarded as the hepatic arterial-phase (double arterial-phase technique) as well as that of multidetector CT.
SENSE can also increase the time efficiency of spatial signal encoding in 3D MRA. With SENSE, even ultrafast (sub second) 4D MRA can be realized.
For MRCP acquisition, high-resolution 3D MRCP images can be constantly provided by SENSE. This is because SENSE resolves the presence of the severe motion artifacts due to longer acquisition time. Longer acquisition time, which results in diminishing image quality, is the greatest problem for 3D MRCP imaging.
In addition, SENSE reduces the train of gradient echoes in combination with a faster k-space traversal per unit time, thereby dramatically improving the image quality of single shot echo planar imaging (i.e. T2 weighted, diffusion weighted imaging).
spacer

• View the DATABASE results for 'Sensitivity Encoding' (12).Open this link in a new window

 
Further Reading:
  News & More:
Image Characteristics and Quality
   by www.sprawls.org    
MRI Resources 
Knee MRI - Intraoperative MRI - MRA - Raman Spectroscopy - Abdominal Imaging - Devices
 
Short Minimum Angled ShotInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
spacer
Searchterm 'Ultra' was also found in the following services: 
spacer
News  (116)  Resources  (62)  Forum  (8)  
 
Shoulder MRI
 
MRI of the shoulder with its excellent soft tissue discrimination, and high spatial resolution offers the best noninvasive way to study the shoulder. MRI images of the bone, muscles and tendons of the glenohumeral joint can be obtained in any oblique planes and projections. MRI gives excellent depiction of rotator cuff tears, injuries to the biceps tendon and damage to the glenoid labrum. Shoulder MRI is better than ultrasound imaging at depicting structural changes such as osteophytic spurs, ligament thickening, and acromial shape that may have predisposed to tendon degeneration.
A dedicated shoulder coil and careful patient positioning in external rotation with the shoulder as close as reasonably possible to the center of the magnet is necessary for a good image quality. If possible, the opposite shoulder should be lifted up, so that the patient lies on the imaged shoulder in order to rotate and fix this shoulder to reduce motion during breathing.
Axial, coronal oblique, and sagittal oblique proton density with fat suppression, T2 and T1 provide an assessment of the rotator cuff, biceps, deltoid, acromio-clavicular joint, the glenohumeral joint and surrounding large structures. If a labral injury is suspected, a Fat Sat gradient echo sequence is recommended. In some cases, a direct MR shoulder arthrogram with intra-articular injection of dilute gadolinium or an indirect arthrogram with imaging 20 min. after intravenous injection may be helpful.

See also Imaging of the Extremities.
 
Images, Movies, Sliders:
 Anatomic Imaging of the Shoulder  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 
Radiology-tip.comradArthrography
spacer
Medical-Ultrasound-Imaging.comLow Intensity Pulsed Ultrasound,  Musculoskeletal and Joint Ultrasound
spacer

• View the DATABASE results for 'Shoulder MRI' (3).Open this link in a new window


• View the NEWS results for 'Shoulder MRI' (1).Open this link in a new window.
 
Further Reading:
  News & More:
The Spectrum of Shoulder Pathologies on Magnetic Resonance Imaging: A Pictorial Review
Wednesday, 6 September 2023   by www.cureus.com    
MRI costs wide-ranging
Thursday, 14 April 2011   by www.chieftain.com    
MRE Could Provide A Definitive Diagnosis For People With Muscle Pain, Study Shows
Friday, 30 November 2007   by www.sciencedaily.com    
Peer-Reviewed Study Concludes The FONAR UPRIGHT™ MRI Could Serve as the “Standard Procedure of Care” for Pediatric Shoulder Malady
Wednesday, 30 May 2007   by www.fonar.com    
MRI Resources 
MRI Technician and Technologist Schools - Implant and Prosthesis - Veterinary MRI - Cardiovascular Imaging - Pediatric and Fetal MRI - Contrast Enhanced MRI
 
Siemens Medical Systems
 
www.siemensmedical.com The range of diagnostics and imaging systems of Siemens Medical Systems covers ultrasound, nuclear medicine, angiography, magnetic resonance, computer tomography and patient monitoring. Siemens is one of the three leading MRI manufacturers, which together account for approximately 80 percent of the MRI machines installed worldwide. Siemens currently offers the Allegra 3T MRI, which is for head scanning only, but the company will also be launching the Trio MRI, a 3T whole body scanner.
Siemens has formed partnerships with more than ten research institutions and private practitioners to define a comprehensive MRI examination and compare MR to currently established cardiovascular modalities, thereby defining optimal diagnosis and treatment.

MRI Scanners:

0.2T to 1.0T:
1.5T:
3.0T to 7.0T:
Hybrid Scanners:
Mobile Solutions:
MAGNETOM Espree 1.5T, MAGNETOM Avanto 1.5T and MAGNETOM ESSENZA 1.5T are also offered by Siemens on certified trailers.
Contact Information
MAIL
Siemens Medical Solutions Health Services Corporation
51 Valley Stream Parkway
Malvern, PA 19355
USA
PHONE
+1 610 219 6300
FAX
+1 610 219 8266
spacer

• View the DATABASE results for 'Siemens Medical Systems' (14).Open this link in a new window


• View the NEWS results for 'Siemens Medical Systems' (3).Open this link in a new window.
 
Further Reading:
  Basics:
Siemens Announces FDA Clearance of Magnetom Amira MRI Scanner
Thursday, 21 January 2016   by www.itnonline.com    
  News & More:
siemens-healthineers-and-ucsf-research-partnership-proves-significant-energy-cost
Thursday, 27 April 2023   by www.itnonline.com    
KinetiCor Wins FDA 510(k) Clearance for Motion Correction System for Siemens MAGNETOM Skyra 3T Scanner
Wednesday, 19 February 2020   by finance.yahoo.com    
Ultra-Fast MRI Is Effective in Acute Neurological Emergency Diagnoses
Wednesday, 15 January 2020   by www.diagnosticimaging.com    
Siemens Working on Automated Planning of Cardiac MRI Views
Friday, 8 March 2013   by www.medgadget.com    
The Most Exciting Equation in MRI Siemens MAGNETOM Verio Combines High-Field Imaging and a 70-cm Open-Bore Design
Wednesday, 31 October 2007   by www.biospace.com    
MRI Resources 
Quality Advice - Image Quality - Collections - Safety Products - Societies - Case Studies
 
previous      71 - 75 (of 84)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]