| Info Sheets |
| | | | | | | | | | | | | | | | | | | | | | | | |
| Out- side |
| | | | |
|
| | | | | | | Searchterm 'Ultra' was also found in the following services: | | | | |
| | |
| |
|
| | | | | | | | | Further Reading: | | Basics:
|
|
News & More:
| |
| |
| | | | | |
| |
|
(MR mammography) Magnetic resonance imaging of the breast is particularly useful in evaluation of newly diagnosed breast cancer, in women whose breast tissue is mammographically very dense and for screening in women with a high lifetime risk of breast cancer because of their family history or genetic disposition.
Breast MRI can be performed on all standard whole body magnets at a field strength of 0.5 T - 1.5 Tesla. Powerful gradient strengths over 15 mT/m will help to improve the balance between spatial resolution, scanning speed, and volume coverage. The use of a dedicated bilateral breast coil is obligatory.
Malignant lesions release angiogenic factors that increase local vessel density and vessel permeability. Breast cancer is detectable due to the strong enhancement in dynamic breast imaging that peaks early (about 1-2 min.) after contrast medium injection. If breast cancer is suspected, a breast biopsy may be necessary to secure the diagnosis. See also Magnetic Resonance Imaging MRI, Biopsy and MR Guided Interventions.
Requirements in breast MRI procedures:
•
Both breasts must be measured without gaps.
•
For the best possible detection of enhancement fat signal should be eliminated either by image subtraction or by
spectrally selective fat saturation.
•
Thin slices are necessary to assure absence of partial
volume effects.
•
Imaging should be performed with a spatial
resolution in plane less than 1 mm.
For Ultrasound Imaging (USI) see Breast Ultrasound at Medical-Ultrasound-Imaging.com.
See also the related poll result: ' MRI will have replaced 50% of x-ray exams by' | | | | | | | | | | | • View the DATABASE results for 'Breast MRI' (13).
| | | • View the NEWS results for 'Breast MRI' (41).
| | | | Further Reading: | Basics:
|
|
News & More:
| |
Technology advances in breast cancer screenings lead to early diagnosis Friday, 6 October 2023 by ksltv.com | | |
Are synthetic contrast-enhanced breast MRI images as good as the real thing? Friday, 18 November 2022 by healthimaging.com | | |
Abbreviated breast MRI protocols not as cost-effective as promised, new study shows Wednesday, 20 July 2022 by healthimaging.com | | |
Deep learning poised to improve breast cancer imaging Thursday, 24 February 2022 by www.eurekalert.org | | |
Pre-Operative Breast MRI Can Help Identify Patients Likely to Experience Nipple-Sparing Mastectomy Risks Wednesday, 7 April 2021 by www.diagnosticimaging.com | | |
Breast cancer screening recalls: simple MRI measurement could avoid 30% of biopsies Monday, 1 March 2021 by www.eurekalert.org | | |
A Comparison of Methods for High-Spatial-Resolution Diffusion-weighted Imaging in Breast MRI Tuesday, 25 August 2020 by pubs.rsna.org | | |
Pre-Operative Breast MRI Diagnoses More Cancers in Women with DCIS Thursday, 9 July 2020 by www.diagnosticimaging.com | | |
Breast MRI and tumour biology predict axillary lymph node response to neoadjuvant chemotherapy for breast cancer Thursday, 26 December 2019 by cancerimagingjournal.biomedcentral.com | | |
Breast MRI Coding Gets an Overhaul in 2019 Wednesday, 9 January 2019 by www.aapc.com | | |
How accurate are volumetric software programs when compared to breast MRI? Thursday, 27 July 2017 by www.radiologybusiness.com | | |
Additional Breast Cancer Tumors Found on MRI After Mammography May Be Larger, More Aggressive Wednesday, 9 December 2015 by www.oncologynurseadvisor.com | | |
Preoperative MRI May Overdiagnose Contralateral Breast Cancer Wednesday, 2 December 2015 by www.cancertherapyadvisor.com | | |
BI-RADS and breast MRI useful in predicting malignancy Wednesday, 30 May 2012 by www.oncologynurseadvisor.com |
|
| |
| | | | | |
| |
|
In the last years, cardiac MRI techniques have progressively improved. No other noninvasive imaging modality provides the same degree of contrast and temporal resolution for the assessment of cardiovascular anatomy and pathology. Contraindications MRI are the same as for other magnetic resonance techniques.
The primary advantage of MRI is extremely high contrast resolution between different tissue types, including blood. Moreover, MRI is a true 3 dimensional imaging modality and images can be obtained in any oblique plane along the true cardiac axes while preserving high temporal and spatial resolution with precise demonstration of cardiac anatomy without the administration of contrast media.
Due to these properties, MRI can precisely characterize cardiac function and quantify cavity volumes, ejection fraction, and left ventricular mass. In addition, cardiac MRI has the ability to quantify flow (see flow quantification), including bulk flow in vessels, pressure gradients across stenosis, regurgitant fractions and shunt fractions. Valve morphology and area can be determined and the severity of stenosis quantified. In certain disease states, such as myocardial infarction, the contrast resolution of MRI is further improved by the addition of extrinsic contrast agents (see myocardial late enhancement).
A dedicated cardiac coil, and a field strength higher than 1 Tesla is recommended to have sufficient signal. Cardiac MRI acquires ECG gating. Cardiac gating (ECGs) obtained within the MRI scanner, can be degraded by the superimposed electrical potential of flowing blood in the magnetic field. Therefore, excellent contact between the skin and ECG leads is necessary. For male patients, the skin at the lead sites can be shaved. A good cooperation of the patient is necessary because breath holding at the end of expiration is practiced during the most sequences.
See also Displacement Encoding with Stimulated Echoes.
For Ultrasound Imaging (USI) see Cardiac Ultrasound at Medical-Ultrasound-Imaging.com.
See also the related poll results: ' In 2010 your scanner will probably work with a field strength of' and ' MRI will have replaced 50% of x-ray exams by' | | | | | | • View the DATABASE results for 'Cardiac MRI' (15).
| | | • View the NEWS results for 'Cardiac MRI' (15).
| | | | Further Reading: | Basics:
|
|
News & More:
| |
MRI technology visualizes heart metabolism in real time Friday, 18 November 2022 by medicalxpress.com | | |
Even early forms of liver disease affect heart health, Cedars-Sinai study finds Thursday, 8 December 2022 by www.eurekalert.org | | |
MRI sheds light on COVID vaccine-associated heart muscle injury Tuesday, 15 February 2022 by www.sciencedaily.com | | |
Radiologists must master cardiac CT, MRI to keep pace with demand: The heart is not a magical organ Monday, 1 March 2021 by www.radiologybusiness.com | | |
Diffusion weighted imaging (DWI) and diffusion tensor imaging (DTI) in the heart (myocardium) Sunday, 30 August 2020 by github.com | | |
Non-invasive diagnostic procedures for suspected CHD: Search reveals informative evidence Wednesday, 8 July 2020 by medicalxpress.co | | |
Cardiac MRI Becoming More Widely Available Thanks to AI and Reduced Exam Times Wednesday, 19 February 2020 by www.dicardiology.com | | |
Controlling patient's breathing makes cardiac MRI more accurate Friday, 13 May 2016 by www.upi.com | | |
Precise visualization of myocardial injury: World's first patient-based cardiac MRI study using 7T MRI Wednesday, 10 February 2016 by medicalxpress.com | | |
New technique could allow for safer, more accurate heart scans Thursday, 10 December 2015 by www.gizmag.com |
|
| |
| | | Searchterm 'Ultra' was also found in the following services: | | | | |
| | |
| |
|
A large network of interconnecting blood vessels at the base of the brain that when visualized resembles a circle, the arteries effectively act as anastomoses for each other. This means that if any one of the communicating arteries becomes blocked, blood can flow from another part of the circle to ensure that blood flow is not compromised.
The circle of Willis is formed by both the internal carotid arteries, entering the brain from each side and the basilar artery, entering posteriorly. The connection of the vertebral arteries forms the basilar artery. The basilar artery divides into the right and left posterior cerebral arteries.
The internal carotid arteries trifurcate into the anterior cerebral artery, middle cerebral artery, and posterior communicating artery.
The two anterior cerebral arteries are joined together anteriorly by the anterior communicating artery. The posterior communicating arteries join the posterior cerebral arteries, completing the circle of Willis. The time of flight angiography MRI technique allows imaging of the circle of Willis without the need of a contrast medium (best results with high field MRI). A cerebrovasular contrast enhanced magnetic resonance angiography ( MRA) depicts the circle of Willis in addition to the vessels of the neck (carotid and vertebral arteries) with one bolus injection of a contrast agent.
For Ultrasound Imaging (USI) see Cerebrovascular Ultrasonography at Medical-Ultrasound-Imaging.com. | | | | | | • View the DATABASE results for 'Circle of Willis' (5).
| | | | Further Reading: | News & More:
|
|
| |
| | | | | |
| |
|
Contrast agents are chemical substances introduced to the anatomical or functional region being imaged, to increase the differences between different tissues or between normal and abnormal tissue, by altering the relaxation times. MRI contrast agents are classified by the different changes in relaxation times after their injection.
•
Negative contrast agents (appearing predominantly dark on MRI) are small particulate aggregates often termed superparamagnetic iron oxide ( SPIO). These agents produce predominantly spin spin relaxation effects (local field inhomogeneities), which results in shorter T1 and T2 relaxation times.
SPIO's and ultrasmall superparamagnetic iron oxides ( USPIO) usually consist of a crystalline iron oxide core containing thousands of iron atoms and a shell of polymer, dextran, polyethyleneglycol, and produce very high T2 relaxivities. USPIOs smaller than 300 nm cause a substantial T1 relaxation. T2 weighted effects are predominant.
•
A special group of negative contrast agents (appearing dark on MRI) are perfluorocarbons ( perfluorochemicals), because their presence excludes the hydrogen atoms responsible for the signal in MR imaging.
The design objectives for the next generation of MR contrast agents will likely focus on prolonging intravascular retention, improving tissue targeting, and accessing new contrast mechanisms. Macromolecular paramagnetic contrast agents are being tested worldwide. Preclinical data shows that these agents demonstrate great promise for improving the quality of MR angiography, and in quantificating capillary permeability and myocardial perfusion.
Ultrasmall superparamagnetic iron oxide ( USPIO) particles have been evaluated in multicenter clinical trials for lymph node MR imaging and MR angiography, with the clinical impact under discussion. In addition, a wide variety of vector and carrier molecules, including antibodies, peptides, proteins, polysaccharides, liposomes, and cells have been developed to deliver magnetic labels to specific sites. Technical advances in MR imaging will further increase the efficacy and necessity of tissue-specific MRI contrast agents.
See also Adverse Reaction and Nephrogenic Systemic Fibrosis.
See also the related poll result: ' The development of contrast agents in MRI is' | | | | | | | | | | | • View the DATABASE results for 'Contrast Agents' (122).
| | | • View the NEWS results for 'Contrast Agents' (25).
| | | | Further Reading: | Basics:
|
|
News & More:
| |
Brain imaging method may aid mild traumatic brain injury diagnosis Tuesday, 16 January 2024 by parkinsonsnewstoday.com | | |
A Targeted Multi-Crystalline Manganese Oxide as a Tumor-Selective Nano-Sized MRI Contrast Agent for Early and Accurate Diagnosis of Tumors Thursday, 18 January 2024 by www.dovepress.com | | |
FDA Approves Gadopiclenol for Contrast-Enhanced Magnetic Resonance Imaging Tuesday, 27 September 2022 by www.pharmacytimes.com | | |
How to stop using gadolinium chelates for magnetic resonance imaging: clinical-translational experiences with ferumoxytol Saturday, 5 February 2022 by www.ncbi.nlm.nih.gov | | |
Estimation of Contrast Agent Concentration in DCE-MRI Using 2 Flip Angles Tuesday, 11 January 2022 by pubmed.ncbi.nlm.nih.gov | | |
Manganese enhanced MRI provides more accurate details of heart function after a heart attack Tuesday, 11 May 2021 by www.news-medical.net | | |
Gadopiclenol: positive results for Phase III clinical trials Monday, 29 March 2021 by www.pharmiweb.co | | |
Gadolinium-Based Contrast Agents Hypersensitivity: A Case Series Friday, 4 December 2020 by www.dovepress.com | | |
Polysaccharide-Core Contrast Agent as Gadolinium Alternative for Vascular MR Monday, 8 March 2021 by www.diagnosticimaging.com | | |
Water-based non-toxic MRI contrast agents Monday, 11 May 2020 by chemistrycommunity.nature.com | | |
New method to detect early-stage cancer identified by Georgia State, Emory research team Friday, 7 February 2020 by www.eurekalert.org | | |
Researchers Brighten Path for Creating New Type of MRI Contrast Agent Friday, 7 February 2020 by www.newswise.com | | |
Manganese-based MRI contrast agent may be safer alternative to gadolinium-based agents Wednesday, 15 November 2017 by www.eurekalert.org | | |
Sodium MRI May Show Biomarker for Migraine Friday, 1 December 2017 by psychcentral.com | | |
A natural boost for MRI scans Monday, 21 October 2013 by www.eurekalert.org | | |
For MRI, time is of the essence A new generation of contrast agents could make for faster and more accurate imaging Tuesday, 28 June 2011 by scienceline.org |
|
| |
| | | | |
| | | |
|
| |
| Look Ups |
| |