Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'superparamagnetic' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'superparamagnetic' found in 5 terms [] and 37 definitions []
previous     21 - 25 (of 42)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9]
Searchterm 'superparamagnetic' was also found in the following services: 
spacer
News  (7)  Forum  (1)  
 
Bolus Injection
 
A bolus is a rapid infusion of high dose contrast agent. Dynamic and accumulation phase imaging can be performed after bolus injection. Since the transit time of the bolus through the tissue is only a few seconds, high temporal resolution imaging can be required to obtain sequential images during the wash in and wash out of the contrast material and, therefore, resolve the first pass of the tracer.
For the same injected dose of contrast agent the injection rate (and, consequently, the total injected volume) modifies the bolus peak profile. Increasing the injection rate produces a sharpening of the peak (Cmax increase, Tmax decrease, peak length decrease). At a low injection rate, the first pass presents a plateau form. Substantial changes in the gadolinium concentrations during signal acquisition induce artifacts. Furthermore, the haemodynamic parameters (cardiac output, blood pressure) influence the bolus profile. The characteristics of gadolinium agents are favorable in the early bolus phase, whereas the advantages of large complexes (e.g. blood pool agents) and ultrasmall superparamagnetic iron oxide (USPIO) are most evident in the distribution phase.
 
Images, Movies, Sliders:
 Left Circumflex Ischemia First-pass Contrast Enhancement  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 Normal Lung Gd Perfusion MRI  Open this link in a new window
 
spacer
 
Further Reading:
  News & More:
Contrast Bolus Timing and Scan Delay
2003   by www.med.nyu.edu    
MRI Resources 
Hospitals - Case Studies - Mobile MRI Rental - Jobs - MRI Reimbursement - Safety Products
 
Clariscan™InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
An iron-based contrast agent with large molecular size, which prevents diffusion into body tissues and will be developed for MR imaging of the liver (taken up by macrophages), tumor microvasculature and microvessel permeability. The blood half live of the particles with 11-20 nm diameter is 3-4 hours.
At this time the development of Clariscan™ is discontinued.

See also NC100150 Injection and Ultrasmall Superparamagnetic Iron Oxide.
Drug Information and Specification
NAME OF COMPOUND
Feruglose, PEG-feron, USPIO, NC100150
DEVELOPER
CENTRAL MOIETY
Fe
CONTRAST EFFECT
T2, Predominantly negative enhancement
R1=20, R2=35, B0=0.5T
PHARMACOKINETIC
Intravascular
CONCENTRATION
29.8 mg Fe/mL
PREPARATION
Suspend in an isotonic glucose solution
INDICATION
Cardiovascular
DEVELOPMENT STAGE
?
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
spacer

• View the DATABASE results for 'Clariscan™' (6).Open this link in a new window

 
Further Reading:
  News & More:
GE Healthcare expands MRI contrast media product range in Europe with launch of macrocyclic agent ClariscanTM
Wednesday, 1 March 2017   by www.businesswire.com    
GE Healthcare announces FDA approval of macrocyclic MRI contrast agent Clariscan
Monday, 4 November 2019   by www.itnonline.com    
MRI Resources 
Cochlear Implant - Knee MRI - Chemistry - MRI Centers - Stimulator pool - Contrast Enhanced MRI
 
Combidex®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Combidex® is the brand name (same as Sinerem®) for an ultrasmall superparamagnetic iron oxide (USPIO) in the development pipeline to detect metastatic disease in lymph nodes. Metastatic lymph nodes show less uptake of this MRI contrast agent, which results in less signal decrease and allows the differentiation of normal lymph nodes from normal-sized, metastatic nodes. Combidex® has also potential to be used as a functional molecular imaging agent.
In March 2005, AMAG Pharmaceuticals Inc received an approvable letter from the U.S. Food and Drug Administration with respect to Combidex subject to certain conditions.
See also Ferumoxtran, Drug Development and Approval Process USA, Molecular Imaging and Classifications, Characteristics, etc.
Drug Information and Specification
NAME OF COMPOUND
Ferumoxtran, USPIO, AMI-227
CENTRAL MOIETY
Fe3+/Fe2+
CONTRAST EFFECT
T1, predominantly T2
r1=25, r2=160, B0=0.47T, r1=23.3, r2=48.9, B0=0.47T
PHARMACOKINETIC
Vascular, lymph v. hepatocyte (AG-USPIO)
DOSAGE
2.6 mg Fe/kg
PREPARATION
Suspend in an isotonic glucose solution
INDICATION
Lymph node, (MR angiography vascular, staging of RES-directed liver diseases)
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
spacer

• View the DATABASE results for 'Combidex®' (6).Open this link in a new window


• View the NEWS results for 'Combidex®' (1).Open this link in a new window.
 
Further Reading:
  Basics:
The demise of Combidex - Sinerem
Wednesday, 24 March 2010   by www.wellsphere.com    
  News & More:
Combidex, MRI, and identification of nodal metastases
Wednesday, 17 June 2009   by prostatecancerinfolink.net    
Superparamagnetic Iron Oxide–enhanced MR Imaging of Head and Neck Lymph Nodes1
Searchterm 'superparamagnetic' was also found in the following services: 
spacer
News  (7)  Forum  (1)  
 
Contrast Enhanced MRIInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Enhanced MRI -
 
Contrast enhanced MRI is a commonly used procedure in magnetic resonance imaging. The need to more accurately characterize different types of lesions and to detect all malignant lesions is the main reason for the use of intravenous contrast agents.
Some methods are available to improve the contrast of different tissues. The focus of dynamic contrast enhanced MRI (DCE-MRI) is on contrast kinetics with demands for spatial resolution dependent on the application. DCE-MR imaging is used for diagnosis of cancer (see also liver imaging, abdominal imaging, breast MRI, dynamic scanning) as well as for diagnosis of cardiac infarction (see perfusion imaging, cardiac MRI). Quantitative DCE-MRI requires special data acquisition techniques and analysis software.
Contrast enhanced magnetic resonance angiography (CE-MRA) allows the visualization of vessels and the temporal resolution provides a separation of arteries and veins. These methods share the need for acquisition methods with high temporal and spatial resolution.
Double contrast administration (combined contrast enhanced (CCE) MRI) uses two contrast agents with complementary mechanisms e.g., superparamagnetic iron oxide to darken the background liver and gadolinium to brighten the vessels. A variety of different categories of contrast agents are currently available for clinical use.
Reasons for the use of contrast agents in MRI scans are:
Relaxation characteristics of normal and pathologic tissues are not always different enough to produce obvious differences in signal intensity.
Pathology that is sometimes occult on unenhanced images becomes obvious in the presence of contrast.
Enhancement significantly increases MRI sensitivity.
In addition to improving delineation between normal and abnormal tissues, the pattern of contrast enhancement can improve diagnostic specificity by facilitating characterization of the lesion(s) in question.
Contrast can yield physiologic and functional information in addition to lesion delineation.
Imaging of arteries and veins with contrast enhanced angiography (CE MRA).

Common Indications:
Brain MRI : Preoperative/pretreatment evaluation and postoperative evaluation of brain tumor therapy, CNS infections, noninfectious inflammatory disease and meningeal disease.
Spine MRI : Infection/inflammatory disease, primary tumors, drop metastases, initial evaluation of syrinx, postoperative evaluation of the lumbar spine: disk vs. scar.
Breast MRI : Detection of breast cancer in case of dense breasts, implants, malignant lymph nodes, or scarring after treatment for breast cancer, diagnosis of a suspicious breast lesion in order to avoid biopsy.

For Ultrasound Imaging (USI) see Contrast Enhanced Ultrasound at Medical-Ultrasound-Imaging.com. See also Blood Pool Agents, Myocardial Late Enhancement, Cardiovascular Imaging, Contrast Enhanced MR Venography, Contrast Resolution, Dynamic Scanning, Lung Imaging, Hepatobiliary Contrast Agents, Contrast Medium and MRI Guided Biopsy.
 
Images, Movies, Sliders:
 Delayed Myocardial Contrast Enhancement from Infarct  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 Left Circumflex Ischemia First-pass Contrast Enhancement  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 Normal Lung Gd Perfusion MRI  Open this link in a new window
 MRI of the Brain Stem with Temoral Bone and Auditory System  Open this link in a new window
    
SlidersSliders Overview

 Breast MRI Images T1 Pre - Post Contrast  Open this link in a new window
 
Radiology-tip.comradContrast Enhanced Computed Tomography
spacer
Medical-Ultrasound-Imaging.comContrast Enhanced Ultrasound,  Contrast Enhanced Doppler Imaging
spacer

• View the DATABASE results for 'Contrast Enhanced MRI' (14).Open this link in a new window


• View the NEWS results for 'Contrast Enhanced MRI' (8).Open this link in a new window.
 
Further Reading:
  Basics:
Optimal k-Space Sampling for Dynamic Contrast-Enhanced MRI with an Application to MR Renography
Thursday, 5 November 2009   by www.ncbi.nlm.nih.gov    
  News & More:
FDA Approves Gadopiclenol for Contrast-Enhanced Magnetic Resonance Imaging
Tuesday, 27 September 2022   by www.pharmacytimes.com    
Effect of gadolinium-based contrast agent on breast diffusion-tensor imaging
Thursday, 6 August 2020   by www.eurekalert.org    
Artificial Intelligence Processes Provide Solutions to Gadolinium Retention Concerns
Thursday, 30 January 2020   by www.itnonline.com    
Accuracy of Unenhanced MRI in the Detection of New Brain Lesions in Multiple Sclerosis
Tuesday, 12 March 2019   by pubs.rsna.org    
The Effects of Breathing Motion on DCE-MRI Images: Phantom Studies Simulating Respiratory Motion to Compare CAIPIRINHA-VIBE, Radial-VIBE, and Conventional VIBE
Tuesday, 7 February 2017   by www.kjronline.org    
Novel Imaging Technique Improves Prostate Cancer Detection
Tuesday, 6 January 2015   by health.ucsd.edu    
New oxygen-enhanced MRI scan 'helps identify most dangerous tumours'
Thursday, 10 December 2015   by www.dailymail.co.uk    
All-organic MRI Contrast Agent Tested In Mice
Monday, 24 September 2012   by cen.acs.org    
A groundbreaking new graphene-based MRI contrast agent
Friday, 8 June 2012   by www.nanowerk.com    
MRI Resources 
Open Directory Project - NMR - Shoulder MRI - MRI Technician and Technologist Jobs - MRI Training Courses - MRI Physics
 
Endorem™InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
A brand name for ferumoxide (same as Feridex®)
Endoremâ„¢ is a black to reddish-brown aqueous colloid of superparamagnetic iron oxide associated with dextran for intravenous administration as a MRI contrast medium for the detection of liver lesions that are associated with an alteration in the RES.
Endoremâ„¢ is taken up by macrophages, found only in healthy liver cells but not in most tumors. Tissues such as metastases, primary liver cancer, cysts and various benign tumors, adenomas and hyperplasia retain their native signal intensity, so the contrast between normal and abnormal tissue is increased.

See also Ferumoxide.
Drug Information and Specification
NAME OF COMPOUND
Dextran-coated ferumoxide, Ami-25
CENTRAL MOIETY
Fe2+/Fe3+
CONTRAST EFFECT
T2, predominantly negative enhancement
r1=40.0, r2=160, B0=0.47T
PHARMACOKINETIC
RES-directed
340 mosm/kgH2O
CONCENTRATION
11.2mg Fe/ml
DOSAGE
15 µmol Fe/kg
PREPARATION
Suspend in an isotonic glucose solution
INDICATION
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Ampoule of 8 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
EU
Brazil
Endorem™
for sale
Argentina
for sale
South Korea
for sale
Israel
for sale
spacer

• View the DATABASE results for 'Endorem™' (5).Open this link in a new window

 
Further Reading:
  News & More:
MAGNETIC RESONANCE IMAGING OF FOCAL LIVER LESIONS(.pdf)
2002
MRI Resources 
Case Studies - Safety Training - Chemistry - MRI Technician and Technologist Schools - Cardiovascular Imaging - Directories
 
previous      21 - 25 (of 42)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]