Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 't1' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 't1' found in 10 terms [] and 165 definitions []
previous     51 - 55 (of 175)     next
Result Pages : [1 2]  [3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
Searchterm 't1' was also found in the following services: 
spacer
News  (18)  Resources  (5)  Forum  (54)  
 
GadoliniumForum -
related threadsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
(Gd) Gadolinium is a Lanthanide element that is paramagnetic in its trivalent state.
This paramagnetic substance is used for MR imaging because of the effect of strongly decreasing the T1 relaxation times of the tissues to which gadolinium has access. When injected during magnetic resonance imaging, gadolinium will tend to change signal intensities by shortening the T1 time in its surroundings.
The relaxivity of gadolinium is an important measure of its efficacy, which is dependent on the chemical properties of the complex. The gadolinium ion cannot be used in its chloride, sulfate, or acetate forms because of poor tolerance and low solubility in water in the neutral pH range. Although toxic by itself, gadolinium can be given safely in a chelated form such as DTPA, that still retains much of its strong effect on relaxation times (relaxivity).

See also Dotarem®, Gadovist®, MultiHance®, Omniscan®, OptiMARK®, and Contrast Agents, the info sheet gives an overview and more in-dept information about different types of MRI contrast agents.
 
Images, Movies, Sliders:
 Normal Lung Gd Perfusion MRI  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 Breast MRI Images T1 Pre - Post Contrast  Open this link in a new window
 Delayed Myocardial Contrast Enhancement from Infarct  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 
spacer
 
• Related Searches:
    • Paramagnetic Contrast Agents
    • Contrast Enhanced Magnetic Resonance Angiography
    • Relaxivity
    • Breast MRI
    • Paramagnetic Substance
 
Further Reading:
  Basics:
DNA-SEEKING GADOLINIUM COMPLEXES FOR NEUTRON CAPTURE THERAPY (NCT) (.pdf)
A LANTHANIDE LANTHOLOGY(.pdf)
   by www.phy.davidson.edu    
Gadolinium-Based Agents Safe for MRI Use
Monday, 18 April 2011   by www.renalandurologynews.com    
  News & More:
Stable Spherical Lanthanide Cluster for Magnetic Resonance Imaging Assembly
Wednesday, 26 April 2023   by www.miragenews.com    
Artificial Intelligence Processes Provide Solutions to Gadolinium Retention Concerns
Thursday, 30 January 2020   by www.itnonline.com    
Contrast Agents: Safety Profile
   by www.clinical-mri.com    
Contrast MRIs cause claims, concern, over residual metal in brain
Tuesday, 8 December 2015   by www.afr.com    
Contrast agent linked with brain abnormalities on MRI
Tuesday, 17 December 2013   by www.sciencecodex.com    
FDA Approves First Macrocyclic and Ionic Gadolinium-Contrast Agent for MRI
Friday, 22 March 2013   by www.itnonline.com    
Multimodal Nanoparticles for Quantitative Imaging(.pdf)
Tuesday, 13 December 2011   by alexandria.tue.nl    
Gadolinium oxide nanoparticles enhance MRI contrast
Thursday, 29 September 2011   by nanotechweb.org    
MRI Resources 
Manufacturers - MRI Accidents - Fluorescence - Education - Brain MRI - Services and Supplies
 
Gadopentetate DimeglumineInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: Gd-DTPA, generic name: Gadopentetate dimeglumine, chemical compound: Gadolinium-diethylenetriaminepentaacetic acid
Gadopentetate dimeglumine was introduced in 1981, as the first paramagnetic MRI contrast agent (ionic). The Gd-induced dipole dipole interactions lead to shortening of T1, which results in contrast enhancement on T1 weighted images. The used metal ion Gd3+ (gadolinium) is toxic, and therefore bound in the renally excreted DTPA chelate, a very stable complex. The Gd-complex also induce susceptibility effects, as a result of the magnetic field gradient between the contrast agent in the blood vessels and the surrounding tissue, that lead to shortening of T2 or T2*.
Following intravenous administration, the compound is distributed rapidly in the extracellular space and is eliminated unchanged by glomerular filtration via the kidneys. Up to 6 hours, post injection an average of 83% of the dose is eliminated renal.

See also Magnevist®, Gadolinium and Contrast Agents.
spacer

• View the DATABASE results for 'Gadopentetate Dimeglumine' (5).Open this link in a new window

 
Further Reading:
  Basics:
Magnevist Package Insert
2000
Gadopentetic acid
   by en.wikipedia.org    
  News & More:
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
MRI Resources 
Developers - MR Myelography - Nerve Stimulator - MRI Training Courses - Implant and Prosthesis pool - Sequences
 
GadoversetamideInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name: Gd-DTPA-BMEA, generic name: Gadoversetamide
A paramagnetic extracellular MRI contrast agent with positive enhancement. When placed in a magnetic field, gadoversetamide decreases T1 and T2 relaxation times in tissues where it accumulates. At the recommended dose, the effect is primarily on T1 relaxation time, and produces an increase in signal intensity (brightness).

See Contrast Agents and OptiMARK™.
spacer

• View the DATABASE results for 'Gadoversetamide' (3).Open this link in a new window


• View the NEWS results for 'Gadoversetamide' (1).Open this link in a new window.
 
Further Reading:
  Basics:
OptiMARK® (gadoversetamide injection)
  News & More:
MAGNETIC RESONANCE IMAGING OF FOCAL LIVER LESIONS(.pdf)
2002
Searchterm 't1' was also found in the following services: 
spacer
News  (18)  Resources  (5)  Forum  (54)  
 
Gastrointestinal Paramagnetic Contrast AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Paramagnetic substances, for example Gd-DTPA solutions, are used as MRI oral contrast agents in gastrointestinal imaging to depict the lumen of the digestive organs. Different Gd-DTPA solutions or zeolites containing gadolinium can be used e.g., for diagnosis of delayed gastric emptying, diagnosis of Crohn's disease etc.
Low concentrations of gastrointestinal paramagnetic contrast agents cause a reduction in T1 relaxation time; consequently, these agents act on T1 weighted images by increasing the signal intensity of the bowel lumen. High concentrations cause T2 shortening by decreasing the signal, similar to superparamagnetic iron oxide. Gd-DTPA chelates are unstable at the low pH in the stomach, therefore buffering is necessary for oral use.

See also Gadopentetate Gastrointestinal, Gadolinium Zeolite, Negative Oral Contrast Agents, Gastrointestinal Superparamagnetic Contrast Agents, and Ferric ammonium citrate.
 
Images, Movies, Sliders:
 MR Colonography Gadolinium per Rectum  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 
spacer

• View the DATABASE results for 'Gastrointestinal Paramagnetic Contrast Agents' (5).Open this link in a new window

MRI Resources 
Spine MRI - PACS - MRI Physics - Image Quality - Sequences - Services and Supplies
 
Gradient Echo Multi SliceInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(GEMS) This pulse sequence uses a changeable flip angle instead of a 90° pulse and a gradient instead of a RF pulse to rephase the FID.
T2*, T1 weighted and proton density images can be acquired. The flip angle in combination with the TR determines the T1 weighting and the TE controls the amount of dephasing. To minimize T2* the echo time should be short.

See also Gradient Echo Sequence.
spacer
MRI Resources 
Fluorescence - General - Journals - Shielding - Shoulder MRI - Services and Supplies
 
previous      51 - 55 (of 175)     next
Result Pages : [1 2]  [3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]