Result: Searchterm '3t'
found in 41 messages |
Result Pages: 1 2 3 4 5 [6] 7 8 9 |
More Results: Database (23) News Service (45) Resources (6) |
|
adam wootton
Thu. 26 Aug.10, 16:58
[Reply (2 of 3) to: '3T imaging parameters' started by: 'Nancy Dudek' on Fri. 26 Aug.05]

Category:
Sequences and Imaging Parameters |
3T imaging parameters |
All your parameters will be the same in a 3T as in the 1.5T except for the T1's TR. T1 TR is 700 to 1300.
|
| View the whole thread | | |
Reader Mail
Tue. 8 Jun.10, 21:23
[Start of: 'Breast MRI selection-PLEASE HELP!' 1 Reply]

Category:
Applications and Examinations |
Breast MRI selection-PLEASE HELP! |
Hi, i am new here..if this is in the wrong forum, PLEASE relocate, THANK YOU!!
I am not familiar with Breast MRIs and i need an advice on the most up todate Breast MRI as i may have b.cancer.
I have family history, maternal side and dense breast, thus the MRI.
I was offered 1) Siemens MAGNETOM Espree 1.5T
2) The Aurora® 1.5T Dedicated Breast MRI System with Bilateral 3-D SpiralRODEO™
3) Phyllips 3T Breast MRI
PLEASE, PLEASE HELP!!! Which one and WHY?
THANK YOU!!!
Eva.
|
| View the whole thread | Reply to this thread (login or register first) | |
Michiel Klitsie
Wed. 2 Jun.10, 14:53
[Start of: 'Imaging of the sacral plexus' 1 Reply]

Category:
Applications and Examinations |
Imaging of the sacral plexus |
We are students Technical Medicine from Twente University and are researching the imaging of the anatomical variation of the sacral plexus. This means the imaging of nerves in a fatty/muscle enviroment with a diameter below 1 mm.rnrnWe are interested in different MR-sequences that will show these small nerves (at the moment we came up with MP(2)Rage, STIR, normal SE T1 and DW) Does anybody can provide us why we should or shouldn't use one of these sequences. Or maybe somebody does have a better suggestion?rnrnAlso we were planning to combine spinal and abdominal coils (phased-array RF coils), does this depict the sacral plexus in a good way?rnrnWe also thought about using a 7T MRI scanner, because of the high spatial resolution. Is this a possibility or does it give to much artifacts? Or is the spatial resolution in a 3T machine enough for such small nerves?rnrnThanks in advance!
|
| View the whole thread | Reply to this thread (login or register first) | |
Daniel Robertson
Thu. 23 Jul.09, 04:54
[Start of: 'MRI Spinal Ligaments' 0 Reply]

Category:
Applications and Examinations |
MRI Spinal Ligaments |
I am a graduate student conducting research on spinal ligament mechanics. I am looking for a good imaging sequence to determine the geometry of the supraspinous ligament. I am working with cadaver specimens so patient motion and scan time is of little relevance. I am just looking to get the highest resolution possible so that I can render a 3d volume of the supraspinous ligament. I am using a GE Signa HDx 3T. Thanks.
|
| | Reply to this thread (login or register first) | |
shyam sundar
Thu. 19 Mar.09, 03:09
[Reply (3 of 26) to: 'MRI Technologists Jobs in Saudi Arabia' started by: 'Mosta Mosta' on Tue. 3 Mar.09]

Category:
Jobs |
MRI Technologists Jobs in Saudi Arabia |
Hi,
Am SHYAM SUNDAR, MRI technologist.
I took my diploma in radiology in 1990-92 at
christian medical college at vellore India.
I have about 8 yrs experience in MRI worked in philips gyroscan 0.5T,Philips intera 3T and siemiens 1.5T.
If you are interested plz reply to email add:
shyama_sundara@yahoo.co.in with full details.
ThanQ
regards,
shyam.
|
| View the whole thread | |
| |