Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 

How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 




 
MRI Forum
'AIN'
SEARCH FORUM FOR   
 
Result: Searchterm 'AIN' found in 209 messages
Result Pages: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 [29] 30 31 32 33 34 35 36 37 38 39 40 41 42 
More Results: Database  (389)  News Service  (888)  Resources  (128)  
Forum Overview
 bottom
Sandra Wilson

Sat. 10 Jan.09,
03:43

[Reply (1 of 7) to:
'Which MRI machine to buy?'
started by: 'Mike Benji'
on Fri. 12 Dec.08]


 
  Category: 
Devices, Scanner, Machines

 
Which MRI machine to buy?
Hi Mike,

Is this your first MRI scanner purchase? I would recommend GE over Hitachi because it is more universal and it will be easier (and less expensive) to get service and refurbished parts. When you say high field do you mean 3.0? Since those are so costly, a 1.5T will give you the best value. That's what we currently use and with the right coils we obtain high quality images.

Hope that helps,
Sandra
 View the whole thread
Sam Shelly

Sun. 2 Nov.08,
23:02

[Reply (2 of 3) to:
'Regarding recovery and decay [basic phycisc]'
started by: 'harry sanders'
on Sat. 7 Jun.08]


 
  Category: 
Basics and Physics

 
Regarding recovery and decay [basic phycisc]
Right on.

Recovery and delay are two separate physical processes like the last guy said. It had me stumped for a while when I was studying as well. But read carefully and think hard about it...

T1 recovery is the return of net magnetization into alignment with b0.

T2 decay is a totally different process and is, as the previous person said, simply loss of net magnetization in the transverse plain due to dephasing. The more electrons that are precessing in phase in the transverse plane, the stronger the NMV is in that plane. And, hence forth, when the RF pulse terminates, the influence of b0 gradually dephases the electrons in the transverse plane. As they dephase, the transverse NMV decreases accordingly, until the next pulse hits, rephasing the electrons and starting the process all over.

Hope that helps. MRI physics is hairy and boring at times. Load up on expressos to stay awake and stick with it, because studying MRI physics can be like taking a bottle of sleeping pills.
 View the whole thread
Piotr Wdowiak

Mon. 27 Oct.08,
17:12

[Reply (4 of 5) to:
'Mobile MRI - Keeping Magnet Cold'
started by: 'Will B'
on Thu. 23 Oct.08]


 
  Category: 
Devices, Scanner, Machines

 
Mobile MRI - Keeping Magnet Cold
Hi
Majority of mobile MRI scanners got onboard generators.
Once you plug off scanner from main external pawer onboard generator will start automaticly.
It keeps chiler running during the transport.
Onboard generator alows you switch on the system , but I wouldn't scan using onboard generator. This is just to keep running system when power supply failure.
 View the whole thread
Will B

Fri. 24 Oct.08,
18:07

[Reply (2 of 5) to:
'Mobile MRI - Keeping Magnet Cold'
started by: 'Will B'
on Thu. 23 Oct.08]


 
  Category: 
Devices, Scanner, Machines

 
Mobile MRI - Keeping Magnet Cold
Thanks for the reply! Very interesting. So after the ramp off, and the vehicle is in motion, do you have to continue to keep the chiller powered? Or does the ramp off alleviate that need?

Thanks again,

Will
 View the whole thread
Maricella Sauceda

Thu. 16 Oct.08,
22:33

[Start of:
'Translation of MRI Result - Help'
0 Reply]


 
  Category: 
Applications and Examinations

 
Translation of MRI Result - Help
Okay... So below is what the MRI breakdown tells me, can someone tell me if I should definitely be worried... I think it says I have brain lessions associated to sinus problems, but then they said it might be a sign of MS? HELP... Any additional clarity will be greatly appreciated...

Technique: Sequences spin - echo-enhanced in T1, T2 protons and density, flair at the axial, sagittal and coronal, 5 mm thick.

Report:
Small punctate signals focal hypo-intense in T1 and hypertensive in the other sequences and without apparent mass effect in the lobar white matter and subcortical frontal, bilateral parietal subcortical and peri-ventricular the atriums of both lateral ventricles.
Others are not displayed disturbances of encephalic parenchyma or blood collections or intra extraxiales. The medulla oblongata, pons and the cerebral peduncles with normal morphology and signal. Tanks of the base, the subarachnoid space and the cortical ventricular system above and infratentorial not dilated, without compression or movement.
Thickening of the lining which is the frontal sinuses, ceidillas etmoidales and maxillary sinuses, in the latter left with the presence of liquid level.

Comments
Many small pictures that compromise the lobar white matter and subcortical frontoparietal and peri-ventricular atrial bilateral and that although might be nonspecific, it is not possible to rule out entirely demyelinating etiology, so it must be correlated with the clinic's patient, findings of physical examination and clinical-. A new study of control in timely fashion or according to clinical course can be useful.
Pan-chronic sinusitis with signs of acute in the left maxillary sinus.
Reply to this thread
(login or register first)

Result Pages : 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 [29] 30 31 32 33 34 35 36 37 38 39 40 41 42 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 September 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]