Bob Owen

Sun. 10 Apr.22,
11:49

[Start of:
'Query on PROPELLER enhancement'
0 Reply]


 
  Category: 
Artifacts

 
Query on PROPELLER enhancement
I looked at an MRI from 2016 I originally had for a tongue swelling to see if it might show evidence for Optic neuritis which I believe I had at that time. I noticed coronal slices show the outer circumference of the optic nerve as especially bright and ragged or irregular along much of the length (both eyes). This looks like donut sign for ON but I wonder if it could be an artefact of the imaging process as it used something called PROPELLER which I believe enhances the image. An axial slice also appears to show the tram track sign. Can anyone comment. I have uploaded a screenshot of just a single coronal slice
 
 

See uploaded slice
Reply to this thread
(login or register first)
We Are ISS

Fri. 28 Jan.22,
02:16

[Start of:
'What is the career growth in MRI technology?'
0 Reply]


 
  Category: 
General

 
What is the career growth in MRI technology?
The career growth for MRI technologists has a very good scope. The MRI technologist has to operate big tube-like machines that use a magnetic field and radio waves to make images of patients' organs, tissue, and bones. So, there is a good scope from them, it is projected to the 9 percent from 2020 to 2030.
Reply to this thread
(login or register first)
Lorenzo Nigris

Sun. 28 Nov.21,
03:43

[Start of:
'ASL Labeling Slab'
0 Reply]


 
  Category: 
Site Planning and Specifications

 
ASL Labeling Slab
Dear all,rnrnI am currently about to set up a pulsed ASL(pASL) sequence on a 3T Siemens MAGNETOM Prisma. Unfortunately, during the plan of the sequence I cannot visualize the labeling slab. Does anybody know how to visualize and set it up? (see Picture)rnrnThanksrn
Reply to this thread
(login or register first)
Gary Brown

Mon. 14 Jun.21,
15:20

[Start of:
'Stents'
0 Reply]


 
  Category: 
General

 
Stents
Employer relates that any cardiac stent implanted after 2008 is safe on ANY MRI scanner within our system. This ranges from 0.3 Open scanners to 1.2 High field Open and 1.5 and 3T closed systems.
Contrarily, the manufacturer data on certain stents states 1.5 or 3 T ONLY, but we are urged to scan on an open if implanted after 2008. Does anyone have any type of testing documentation that this is safe? I'm not so much worried about the field strength as I am the magnetic field orientation as the defining safety issue.
Reply to this thread
(login or register first)
Anton Troitskii

Thu. 24 Sep.20,
03:48

[Start of:
'Contrast in GRE'
0 Reply]


 
  Category: 
Basics and Physics

 
Contrast in GRE
I have found an explanation of GRE contrast in the book "MRI, The Basics - Ray Hashman Hashemi, William G. Bradley Jr., Christopher J. Lisanti - 3rd Ed. Chapter 20. Gradient Echo: Part I (Basic Principles)". Here is a link with a screenshot https://photos.app.goo.gl/88e2iJ7amEQTWg1r9rnA "> https://photos.app.goo.gl/88e2iJ7amEQTWg1r9rnA "longer TR enhances T1 weighting". And a table in the end of the chapter. But there is a contraversions opinion in other sources. For example, http://www.mri-q.com/spoiled-gre-parameters.html.rnrnThere is described that "The lengthening of TR cause increase PD weighting, and shortening TR increase T1 weighting".
Reply to this thread
(login or register first)

Result Pages : 1 2 3 4 5 [6] 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 15 March 2025]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]