Renate Bloemer

Mon. 13 Nov.06,
19:46

[Reply (1 of 3) to:
'MRA'
started by: 'Marco Costa'
on Sun. 22 Oct.06]


 
  Category: 
Protocols

 
MRA
A test bolus helps to get the delay at which time the CE-MRA sequence has to be started. The sequence needed is a one-slice dynamic fast gradient echo sequence (if possible with fat suppression or subtraction) and a temporal resolution of 0.5 to 1.5 sec. This thick slice is placed over the vessel of interest and the dynamic is started simultaneous with a small (1-2ml) bolus of Gad.
In the follow up you can see at which time the bolus is visible. If it is not clear to differentiate, a ROI measurement will help. The starting time depends on the k-space filling. Around the peak of the highest intensity, the contrast information should be read out (with "centric" at the beginning of the sequence).
Centric k-space filling order means that the central lines of the k-space are filled in the first seconds after starting the scan. Depending on the equipment, there is more than one non-centric order, for example linear, where the central lines are filled in the middle of the scan time.
Hope this helps.
 
 

Renate Bloemer
 View the whole thread
Renate Bloemer

Mon. 13 Nov.06,
19:29

[Reply (1 of 2) to:
'T1 FAT SAT PRE AND POS GADO'
started by: 'CLAUDIO RIBERTI'
on Tue. 24 Oct.06]


 
  Category: 
Contrast Agents

 
T1 FAT SAT PRE AND POS GADO
The contrast agent causes this difference. Contrast agents reduce the T1 time in tissues where they have accumulated depending on blood flow and vascular permeability. Caused by this, tissues after an application of contrast agents will differ in shortening of the T1 time, and the same imaging parameters result in other image appearance.
Some helpful links for musculoskeletal imaging and Fat Sat:
http://www.moffitt.org/moffittapps/ccj/v8n3/pdf/221.pdf
http://www.medical.siemens.com/siemens/en_US/gg_mr_FBAs/files/MRI_Hot_Topics/MRI_HotTopics_Skinny_on_FatSat_engl.pdf

Hope this helps
 
 

Renate Bloemer
 View the whole thread
Sheila Edenfield

Thu. 2 Nov.06,
16:03

[Start of:
'MRV--Phase contrast question'
0 Reply]


 
  Category: 
General

 
MRV--Phase contrast question
What exactly is an MRV sequence on an Hitachi Airis II .3 Tesla?
I realize it has to do with the venus system but if anyone knows anything I sure would appreciate your time and knowledge concerning this.

Also The physician I am working under(Neurologist), he would like to see my MRAs done with a phase encoding protocall? Is there such a thing? I hope someone out there can give me some knowledgable info on this. Thank you Sheila/Georgia :)
 
 

Sheila Edenfield
Airis II Hitachi .3T
Stockbridge Ga
sheilamritechnologist@yahoo.com
Reply to this thread
(login or register first)
Stephanie Taylor

Wed. 1 Nov.06,
16:09

[Start of:
'Receiver Bandwidth'
2 Replies]


 
  Category: 
Basics and Physics

 
Receiver Bandwidth
Can someone give me the calculation for finding the receiver bandwidth value. I can't seem to find this anywhere. I swear that I have seen it before.
 View the whole threadReply to this thread
(login or register first)
corey walker

Thu. 26 Oct.06,
19:29

[Start of:
'pgh to dicom conversion?'
1 Reply]


 
  Category: 
General

 
pgh to dicom conversion?
I am using new dti software that will not read pgh. Unfortunately, a large amount of our data was stored in pgh format only. As this software does not read pgh, is there any way to convert pgh format into dicom? I have had no luck with this so far.
 View the whole threadReply to this thread
(login or register first)

Result Pages : 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 [51] 52 53 54 55 56 57 58 59 60 61 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 17 September 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]