Jennifer Jackson

Fri. 21 Jul.06,
04:44

[Reply (1 of 2) to:
'Phase encoding'
started by: 'guillaume bierry'
on Fri. 7 Jul.06]


 
  Category: 
General

 
Phase encoding
Wow this is a long subject, First you have to under stand how the 3 main gradients are used. (slice select, Freq, then phase)
So you are use 1 of the gradients for your phase encoding. You need to fill the k-space which depends on you matrix. Lets assume you are using 256 (phase). In order to fill K-space you have to have 256 aquistions of the signal. Meaning for each picture (or slice) the signal must be acquire(sampled) 256 times each at a differnt amplitude to put it in a different Line of k-space.

Example- If you are performing a SE(spin echo) you have 1 TR period and 1 TE period (TE=is when the signal is sampled) so you will have to do the TR period 256 times to fill K-space with diffent amplitudes.

There is alot more that I left out. If this did not answer your question let me know
 View the whole thread
Michael Semrau

Tue. 30 May.06,
20:18

[Reply (1 of 2) to:
'help me for looking for some gadolinium product'
started by: 'Linqing Li'
on Fri. 21 Oct.05]


 
  Category: 
Contrast Agents

 
help me for looking for some gadolinium product
Linquing,
just saw your thread, and at the same moment this advertisement in another browser:
http://www.baotou.com/
It seems they are trading gadolinium products around the globe.

Regards
Michael
 View the whole thread
Michael Oliver

Sat. 27 May.06,
12:54

[Reply (1 of 3) to:
'ETL for a STIR'
started by: 'Shaun Schofield'
on Thu. 30 Mar.06]


 
  Category: 
Sequences and Imaging Parameters

 
ETL for a STIR
I prefer a range from 5-12 (but using shorter TE and TR). High echo trains can lead to blurring, image noise and contrast inhomogeneities.
Parallel imaging can reduce the longer scan time of low ETLs; also often 1 NSA is enough for sufficient SNR.

Hope this helps!
 View the whole thread
John Dowling

Tue. 9 May.06,
22:36

[Start of:
'Omniscan Distribution Rate'
1 Reply]


 
  Category: 
Contrast Agents

 
Omniscan Distribution Rate
I was told by the GE rep that Omniscan has a faster distribution rate, that should lend itself to better images/application to specific technologies. Is this claim valid? This is the first I've heard of this type "spin" on contrast agents. <pun intended>

In my experience, I have not seen much difference in image quality from various contrast agents. Any thoughts or experiences are appreciated.
 View the whole threadReply to this thread
(login or register first)
Rud Spring

Fri. 7 Apr.06,
21:02

[Reply (1 of 2) to:
'Slew Rate'
started by: 'Reader Mail '
on Sun. 2 Apr.06]


 
  Category: 
Sequences and Imaging Parameters

 
Slew Rate
It's about how fast the gradient coil reaches the amplitude. It's the steepness of the curve. The time it takes to reach this amplitude is often referred to as "rise time".

At certain high slew rates the gradient switching is so fast that peripheral nerves get stimulated. A warning may be given like "possible peripheral nerve stimulation". It's not really dangerous, but you can feel your muscles contract a little. Some people are more sensitive to it than others.
 View the whole thread

Result Pages : 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 [53] 54 55 56 57 58 59 60 61 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 17 September 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]