| Info Sheets |
| | | | | | | | | | | | | | | | | | | | | | | | |
| Out- side |
| | | | |
|
| | | | | |
Result: Searchterm 'hitachi'
found in 28 messages |
Result Pages: 1 [2] 3 4 5 6 |
More Results: Database (5) News Service (13) Resources (7) |
|
LUIS ALBERTO LANDA ROJAS
Tue. 28 Jan.20, 20:58
[Start of: 'DP TRS STIR' 0 Reply]
Category:
Applications and Examinations |
DP TRS STIR |
Hello Goodnight.
I just came across this forum, I have a Hitachi 0.3 T resonance with an Airis II system, which I have trouble doing DP with fat saturation, could someone help me? how should it be done ?????
Regards,
Luis Alberto
|
| | Reply to this thread (login or register first) | |
stephen cody
Fri. 13 Feb.15, 19:42
[Reply (22 of 26) to: 'MRI Technologists Jobs in Saudi Arabia' started by: 'Mosta Mosta' on Tue. 3 Mar.09]
Category:
Jobs |
MRI Technologists Jobs in Saudi Arabia |
Hello I am interested in your mri position please review my resume and let me know if I can be of service. Thank You
Stephen Cody
Stephen M. Cody, ARRT, R, MR
324 Catalpa St. #115
San Mateo CA. 94401
(832) 816-8514
smcody@hotmail.com
Education
Academy of Health Sciences, Fort Sam Houston, San Antonio, Texas
Radiology Technologist Program - September 1977
Summary of qualifications
More than 25 years of radiology experience; 15 years training others
Registered by the ARRT
Fully experienced with diagnostic techniques using CT and MRI
Organized, efficient and a problem-solver
Work experience
San Francisco General Hospital 3/11-present
Optimizing protocols, training staff and doing cardiac MRI.
National Institutes of Health 3/09-2/11
oLead MRI technologist. Trained staff on Siemens MRI scanners, performed cardiac MRI and spectroscopy on the heart and liver. Worked with physicists and radiologists on various research protocols.
Phillips Medical 1/08-2/09
Verification and validation testing on the Phillips iSite Pacs
Contractor 9/04-08
Completed several MRI assignments across the United States, listed below:
Piedmont Medical Center, Rock Hill, S.C.
UC-Davis Hospital, Sacramento, Calif.
Brazosport Memorial Hospital, Lake Jackson, Texas
Bay Medical Center, Panama City, Fla.
Memorial Hermann Hospital System, Houston, Texas
Presbyterian Hospital, Dallas, Texas
Oregon Health Sciences Hospital, Portland, Ore.
Neurology Consultants of Dallas 9/03-3/04
Facilitated startup and operation of the neurology group's MRI services.
Southwest Diagnostic Imaging Center 3/03-12/-03
(Concurrent with neurology center)
Med Relief Staffing 1/00-2/03
National University Hospital of Singapore 2/96-12/99
MRI technologist, responsible for training staff and managing MRI operations.
Jacinto MRI Center 8/93-1/96
Chief technician of this Houston, Texas, center, which initially started with MRI and expanded to a full-range outpatient center. Responsibilities included training staff in CT and MRI; broad technical direction; marketing and RSO.
Spectrum Imaging 4/90-7/92
Manager for this Houston, Texas, center. Was responsible for marketing, business development, technical operations and equipment purchases.
Houston Imaging Centers 1/89-3/90
MRI supervisor, standardizing centers' protocols, including a Q.A. program. Trained several new techs.
The Methodist Hospital 2/84-10/88
Angio, CT technician. Performed and trained in various angio and CT procedures. MRI training began in my last year of employment.
Equipment:
CT: GE 9800, Quick Advantage, Cytech, Siemens DRH
MRI: Technicare.6 Phonar .3 GE Cigna 4X and 5X 9X 14X 16X, 1.5 and 3T; Toshiba Opart; Hitachi 7000 and Aris; Phillips 1.5 NT and T5; Elscint .5; Siemens 1.5 Vision and .2 Open Viva Magnets; Siemens 1.5 Symphony Maestro Class, Avanto and Espirit Verio 3T; Phillips 1.5 Intera 3T Achieva
|
| View the whole thread | | |
Reader Mail
Fri. 8 Jun.12, 18:04
[Start of: 'setting scanner console clock?? airis II' 2 Replies]
Category:
General |
setting scanner console clock?? airis II |
hello, im looking for any input on how to set the clock on the console of a hitachi airis II .3t mr scanner. the clock has overtime fallen more and more behind the actual time and now the clock is so off that the date displayed is incorrect. any help would be greatly appreciated. thank you!!!!
|
| View the whole thread | Reply to this thread (login or register first) | |
Charlie McIntyre
Tue. 17 Apr.12, 16:28
[Start of: 'High Field Open MRI systems/Spatial Gradient limits' 0 Reply]
Category:
Safety |
High Field Open MRI systems/Spatial Gradient limits |
Anyone out there operating a Philips HFO or Hitachi Oasis? If so how is your facility handling the new FDA labeling of MR "conditional" limits of certain implants(stents, shunts, etc..) and the Higher Spatial Gradient Forces that these machines have? thanks.
|
| | Reply to this thread (login or register first) | |
Reader Mail
Sat. 7 Jan.12, 11:29
[Start of: 'Diffusion Weighted Images' 0 Reply]
Category:
Applications and Examinations |
Diffusion Weighted Images |
What are the best sequences for evaluating of the female pelvis. Regarding that I am doing a research on the role of DWI in characterization of female pelvic masses. Our machine is a Hitachi Airis Avento. I did not find the b value, however a diffusion button is there. rn
|
| | Reply to this thread (login or register first) |
| |
| Result Pages : 1 [2] 3 4 5 6 | |
|
| |
| Look Ups |
| |