Eddy Current Compensation
 
Eliminate Gibb's artifact (Border ringing) for sharp images. Means of reducing the influence of eddy currents on pulsed gradient fields by employing an electrical preemphasis in the gradient amplifiers. Usually multiple time constants have to be used to correct for eddy current effects in various structures of the MR system such as the cryoshields and RF-shields.

See also Eddy Currents and Shielded Gradient Coils.
spacer

• View the DATABASE results for 'Eddy Current Compensation' (4).Open this link in a new window

 
Further Reading:
  Basics:
Generic Eddy Current Compensation for Rapid Magnetic Resonance Imaging(.pdf)
   by www.switt.ch    
Eddy CurrentsForum -
there are related threadsInfoSheet: - Artifacts -
Case Studies, 
Reduction Index, 
etc.
 
Electric currents induced in a conductor by a changing magnetic field or by motion of the conductor through a magnetic field.
One of the sources of concern about a potential hazard to subjects in very high magnetic fields or rapidly varying gradient or main magnetic fields. Can be a practical problem in the cryostat of superconducting magnets. Eddy currents can cause artifacts in images and may seriously degrade overall magnet performance. Common means to reduce the influence of eddy currents on gradient fields are eddy current compensation and shielded gradient coils (active or passive).

See also Eddy Current Compensation.

See also the related poll result: 'Most outages of your scanning system are caused by failure of'
spacer

• View the DATABASE results for 'Eddy Currents' (8).Open this link in a new window

 
Further Reading:
  Basics:
Electrical eddy currents in the human body: MRI scans and medical implants
   by www.phy.olemiss.edu    
MRI Resources 
Sequences - Implant and Prosthesis pool - Safety pool - Homepages - Mobile MRI - Corporations
 
Effective Echo Time
 
(TEeff) The contrast and the SNR of an MR image are determined primarily by the temporal position of the echo at which the phase encoding gradient has the smallest amplitude. The echo signal in this case undergoes minimal dephasing and has the strongest signal. The time period between the excitation pulse and this echo is the effective echo time.
spacer

• View the DATABASE results for 'Effective Echo Time' (2).Open this link in a new window

 
Further Reading:
  Basics:
RARE
Monday, 3 December 2012   by www2.warwick.ac.uk    
Clinical evaluation of a speed optimized T2 weighted fast spin echo sequence at 3.0 T using variable flip angle refocusing, half-Fourier acquisition and parallel imaging
Wednesday, 25 October 2006
Fast Spin Echo(.pdf)
Tuesday, 24 January 2006   by www.81bones.net    
EigenvaluesForum -
there are related threads
 
Mathematically, the eigenvalue is the factor by which a linear transformation multiplies one of its eigenvectors. In an appropriate spatial reference frame, the diffusion tensor is diagonal (contains only three nonzero elements). These elements in diffusion tensor imaging are called the eigenvalues. The vectors characterizing the reference frame are the eigenvectors.
spacer

• View the DATABASE results for 'Eigenvalues' (3).Open this link in a new window

Eiken Chemical Co., Ltd.MRI Resource Directory:
 - Manufacturers -
 
www.eiken.co.jp The principal activity of this Japan-based Group, is to manufacture and sell diagnostic substances and reagents. The Group's other activities include wholesale of reagents and analysis equipment. The Group has one consolidated subsidiary located in Japan. Diagnostic substances and reagents accounted for 83% of fiscal 2002 revenues; medical equipment, 12% and blood vessel contrast mediums, 5%. Eiken Chemical Co., Ltd. distributes Feridex®.
Contact Information
MAIL
Eiken Chemical Co., Ltd.
1-33-8 Hongo, Bunkyo-ku
113-8408 Tokyo
JAPAN
PHONE
+81-3-3813-5401
FAX
+81-3-3813-2206
spacer

• View the DATABASE results for 'Eiken Chemical Co., Ltd.' (3).Open this link in a new window

MRI Resources 
Implant and Prosthesis pool - Databases - Claustrophobia - Health - DICOM - MR Guided Interventions
 
previous       16 - 20 (of 48)      next 
E--Ec   Ec-Ec   Ec-Ed    Ed-Ei    El-El   El-En   En-EP   EP-Eu   Ev-Ex   Ex-Ex   
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 23 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]