Any electrical resistance generates thermal noise called Johnson Noise. This noise is also generated by the human body as a consequence of the ionic nature of body tissue and fluids, all active electronic devices (e.g. transistors) generate noise and
noise is transmitted through the ether (radio-signals, interference from electrical equipment, extraterrestrial etc.). | | | | • View the DATABASE results for 'Electronic Noise' (2).
| | | | | | |
|
| |
| | | | | • View the DATABASE results for 'Element' (40).
| | | | | | | | | |
|
| |
| Founded in 1969, Elscint is headquartered in Haifa, Israel. Elscint developed advanced computerized imaging systems in Computed Tomography (CT), Magnetic Resonance Imaging ( MRI), Nuclear Medicine (NM) and Mammography (MAM) for international markets.
In November 1998, General Electric Medical Systems (GEMS) acquired the Nuclear Medicine and MRI divisions of Elscint, including an unique MRI gradient system concept and technology (twin gradient system).
Elscint Ltd. signs definitive agreement to sell its Nuclear Medicine and Magnetic Resonance Imaging Businesses for $100 Million. Elscint's shareholders approved the sale of its NM, and MRI division to GE (now GE Healthcare). Picker International acquires the Computed Tomography Division of Elscint Ltd. in the same year. See also Marconi Medical Systems. | | | | | Further Reading: | | Basics:
|
|
News & More:
| |
| | | |
|
| |
|
'MRI system is not an expensive equipment anymore.
ENCORE developed by ISOL Technology is a low cost MRI system with the advantages like of the 1.0T MRI scanner. Developed specially for the overseas market, the ENCORE is gaining popularity in the domestic market by medium sized hospitals.
Due to the optimum RF and Gradient application technology. ENCORE enables to obtain high resolution imaging and 2D/3D Angio images which was only possible in high field MR systems.'
- Less consumption of the helium gas due to the ultra-lightweight magnet specially designed and manufactured for ISOL.
- Cost efficiency MR system due to air cooling type (equivalent to permanent magnetic).
- Patient processing speed of less than 20 minutes.'
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Short bore compact
| | | | • View the DATABASE results for 'ENCORE 0.5T™' (2).
| | | | | | |
|
| |
| A brand name for ferumoxide (same as Feridex®)
Endoremâ„¢ is a black to reddish-brown aqueous colloid of superparamagnetic iron oxide associated with dextran for intravenous administration as a MRI contrast medium for the detection of liver lesions that are associated with an alteration in the RES.
Endoremâ„¢ is taken up by macrophages, found only in healthy liver cells but not in most tumors. Tissues such as metastases, primary liver cancer, cysts and various benign tumors, adenomas and hyperplasia retain their native signal intensity, so the contrast between normal and abnormal tissue is increased.
See also Ferumoxide.
Drug Information and Specification
T2, predominantly negative enhancement
r1=40.0, r2=160, B0=0.47T
PHARMACOKINETIC
RES-directed
CONCENTRATION
11.2mg Fe/ml
PREPARATION
Suspend in an isotonic glucose solution
DEVELOPMENT STAGE
For sale
PRESENTATION
Ampoule of 8 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING
PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT STAGE
DISTRIBUTOR
EU Brazil
Endorem™
for sale
| | | | • View the DATABASE results for 'Endorem™' (5).