Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 MRI Database 
SEARCH FOR    
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
previous     6 - 10 (of 65)     next 
G--Ga   Ga-Ga     Ga-Ga   Ga-Ga   Ga-Ga   Ga-Gd   Gd-Gd   GE-Gi   Gi-Gr   Gr-Gr   Gr-Gr   Gr-Gr   Gr-Gy   
MRI Resources 
Collections - Diffusion Weighted Imaging - Blood Flow Imaging - Contrast Enhanced MRI - Veterinary MRI - Hospitals
 
GadoliniumForum -
there are related threadsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
(Gd) Gadolinium is a Lanthanide element that is paramagnetic in its trivalent state.
This paramagnetic substance is used for MR imaging because of the effect of strongly decreasing the T1 relaxation times of the tissues to which gadolinium has access. When injected during magnetic resonance imaging, gadolinium will tend to change signal intensities by shortening the T1 time in its surroundings.
The relaxivity of gadolinium is an important measure of its efficacy, which is dependent on the chemical properties of the complex. The gadolinium ion cannot be used in its chloride, sulfate, or acetate forms because of poor tolerance and low solubility in water in the neutral pH range. Although toxic by itself, gadolinium can be given safely in a chelated form such as DTPA, that still retains much of its strong effect on relaxation times (relaxivity).

See also Dotarem®, Gadovist®, MultiHance®, Omniscan®, OptiMARK®, and Contrast Agents, the info sheet gives an overview and more in-dept information about different types of MRI contrast agents.
 
Images, Movies, Sliders:
 Normal Lung Gd Perfusion MRI  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 Breast MRI Images T1 Pre - Post Contrast  Open this link in a new window
 Delayed Myocardial Contrast Enhancement from Infarct  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 
spacer

• View the NEWS results for 'Gadolinium' (17).Open this link in a new window.

• View the DATABASE results for 'Gadolinium' (66).Open this link in a new window

 
Further Reading:
  Basics:
DNA-SEEKING GADOLINIUM COMPLEXES FOR NEUTRON CAPTURE THERAPY (NCT) (.pdf)
A LANTHANIDE LANTHOLOGY(.pdf)
   by www.phy.davidson.edu    
Gadolinium-Based Agents Safe for MRI Use
Monday, 18 April 2011   by www.renalandurologynews.com    
  News & More:
Stable Spherical Lanthanide Cluster for Magnetic Resonance Imaging Assembly
Wednesday, 26 April 2023   by www.miragenews.com    
Artificial Intelligence Processes Provide Solutions to Gadolinium Retention Concerns
Thursday, 30 January 2020   by www.itnonline.com    
Contrast Agents: Safety Profile
   by www.clinical-mri.com    
Contrast MRIs cause claims, concern, over residual metal in brain
Tuesday, 8 December 2015   by www.afr.com    
Contrast agent linked with brain abnormalities on MRI
Tuesday, 17 December 2013   by www.sciencecodex.com    
FDA Approves First Macrocyclic and Ionic Gadolinium-Contrast Agent for MRI
Friday, 22 March 2013   by www.itnonline.com    
Multimodal Nanoparticles for Quantitative Imaging(.pdf)
Tuesday, 13 December 2011   by alexandria.tue.nl    
Gadolinium oxide nanoparticles enhance MRI contrast
Thursday, 29 September 2011   by nanotechweb.org    
Gadolinium OxideInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Gadolinium oxide (Gd2O3) is a prototype paramagnetic agent for contrast enhanced MRI. Gd2O3 particles have very high relaxivity. With its high magnetic moment, gadolinium reduces the relaxation time and enhance MR signal intensity. All gadolinium compounds are highly toxic. Very stable complexes are developed to eliminate the toxicity. See also Paramagnetic Substance, Paramagnetism, Paramagnetic Contrast Agents and Contrast Agents, the info sheet gives an overview and more in-dept information about different types of MRI Contrast media.
spacer

• View the DATABASE results for 'Gadolinium Oxide' (2).Open this link in a new window

 
Further Reading:
  Basics:
Gadolinium oxide nanoparticles enhance MRI contrast
Thursday, 29 September 2011   by nanotechweb.org    
  News & More:
Northern Rare Earth eyes medical device prospects
Thursday, 29 December 2016   by usa.chinadaily.com.cn    
MRI Resources 
Breast MRI - Coils - Jobs pool - Libraries - Brain MRI - MRA
 
Gadolinium ZeoliteInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
(Gadolite® oral Suspension) An oral paramagnetic MRI contrast agent to enhance delineation of the bowel. Zeolites are hydrated aluminosilicates with large holes that can provide a temporary home for guest molecules like gadolinium. Zeolites modified with Gd (III) are effective positive MRI contrast agents for gastrointestinal application.
spacer

• View the DATABASE results for 'Gadolinium Zeolite' (3).Open this link in a new window

Gadolite® Oral SuspensionInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
An oral suspension of synthetic crystalline aqueous orange-flavored MRI contrast agent to enhance delineation of the bowel. Gadolite contains gadolinium, a lanthanide metal with paramagnetic characteristics. The toxic Gd is bound to become inert, along with water, inside a zeolite crystalline lattice structure. Gadolite gives a bright signal, and provides improved definition of the gastrointestinal tract from adjacent tissues.
Pharmacyclics receives an approvable letter from the FDA for Gadolite® Oral Suspension and in the United Kingdom an European marketing agreement signed with E-Z-Em, Ltd. in Dec. 1996.
Drug Information and Specification
NAME OF COMPOUND
Gadolinium zeolite, Gadolinium chloride hexahydrate
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
Paramagnetic
PHARMACOKINETIC
Gastrointestinal
PREPARATION
Oral suspension
INDICATION
Bowel marking
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Suspension
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA, Canada, Mexico, EU
Gadolite® Oral Suspension
for sale
spacer

• View the DATABASE results for 'Gadolite® Oral Suspension' (4).Open this link in a new window

Gadomer 17InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: (Gd-DTPA)-17, 24 cascade polymer, generic name: Gadomer-17, 24, central moiety: Gd2+, relaxivity: r1=11.9, B0=1.0 T, r2=16.5, Dose: 0.05 mmol/kg
An intravascular macromolecular MRI contrast agent with positive enhancement under development (Bayer Schering Pharma AG) for MR angiography and tumor differentiation. The synthetic dendrimer with large molecular weight (17kD - limits agent to vascular space) is linked to Gadolinium. The renal excretion is slowed to intermediate molecular size. In MRA a longer lasting venous and arterial enhancement was seen with Gadomer-17 due to the particular pharmacokinetics of this agent.

See also Tumor Specific Agents, and Intravascular Contrast Agents.
spacer

• View the NEWS results for 'Gadomer 17' (1).Open this link in a new window.

• View the DATABASE results for 'Gadomer 17' (3).Open this link in a new window

 
Further Reading:
  News & More:
Combined MR lymphangiography and MR imaging-guided needle localization of sentinel lymph nodes using Gadomer-17.
2002
MRI Resources 
Knee MRI - Cochlear Implant - Nerve Stimulator - MRI Physics - Most Wanted - Used and Refurbished MRI Equipment
 
previous       6 - 10 (of 65)      next 
G--Ga    Ga-Ga    Ga-Ga   Ga-Ga   Ga-Ga   Ga-Gd   Gd-Gd   GE-Gi   Gi-Gr   Gr-Gr   Gr-Gr   Gr-Gr   Gr-Gy   
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]