Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 MRI Database 
SEARCH FOR    
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
previous     141 - 145 (of 150)     next 
Ma-Ma   Ma-Ma   Ma-Ma   Ma-Ma   Ma-Ma   Ma-Ma   Ma-Ma   MA-MA   MA-MA   MA-MA   MA-Ma   Ma-Ma   Ma-Ma   Ma-Ma   Ma-Me   ME-Me   Me-Mi   Mn-Mo   Mo-Mo   Mo-Mo   Mo-MR   MR-MR   MR-MS   Mu-Mu   Mu-Mu   Mu-Mu   Mu-Mu   Mu-Mu   Mu-Mu     Mu-Mz   
MRI Resources 
MRI Training Courses - Education - Journals - MRI Accidents - Distributors - MR Guided Interventions
 
Multiple Slice ImagingInfoSheet: - Sequences -
Intro, Overview, 
Types of, 
etc.
 
A usual variation of sequential plane imaging technique that can be used with selective excitation technique that does not affect adjacent slices. Since, in SE imaging TR longer than TE, the machine would be idling most of the time, if a single slice would be acquired; multiple slice imaging was introduced early on. Adjacent slices are imaged while waiting for relaxation of the first slice toward equilibrium, resulting in decreased image acquisition time for the set of slices. The maximum number of slices of a pulse sequence depends on the repetition time.
spacer

• View the DATABASE results for 'Multiple Slice Imaging' (4).Open this link in a new window

Multiple Spin Echo
 
A pulse sequence leading to the production of multiple spin echoes after an initial excitation.
spacer
MRI Resources 
Non-English - Cardiovascular Imaging - Used and Refurbished MRI Equipment - Contrast Enhanced MRI - MRCP - Pediatric and Fetal MRI
 
Multiplet
 
A pattern of multiple resonance's (spectral lines) observed when the initially single Larmor frequency of a given nucleus in a spin system is split by interactions with neighboring spins through the scalar or spin spin interaction. The magnitude of this interaction is independent of the applied magnetic field and is referred to as J, the spin spin coupling constant. The specific pattern produced depends on the number of coupled nuclei and their spin quantum numbers.
spacer

• View the DATABASE results for 'Multiplet' (3).Open this link in a new window

Multiply Tuned CoilInfoSheet: - Coils -
Intro, 
Overview, 
etc.MRI Resource Directory:
 - Coils -
 
RF coil designed to operate at more than one resonance frequency, so that NMR of more than one kind of nucleus can be observed with the same coil.
spacer
Multivenc SequenceMRI Resource Directory:
 - Sequences -
 
This angiographic sequence is sensitive to various flow velocities and is used for ,e.g. the peripheral arteries.
spacer
MRI Resources 
Devices - Abdominal Imaging - Jobs - Used and Refurbished MRI Equipment - Service and Support - MR Myelography
 
previous       141 - 145 (of 150)      next 
Ma-Ma   Ma-Ma   Ma-Ma   Ma-Ma   Ma-Ma   Ma-Ma   Ma-Ma   MA-MA   MA-MA   MA-MA   MA-Ma   Ma-Ma   Ma-Ma   Ma-Ma   Ma-Me   ME-Me   Me-Mi   Mn-Mo   Mo-Mo   Mo-Mo   Mo-MR   MR-MR   MR-MS   Mu-Mu   Mu-Mu   Mu-Mu   Mu-Mu   Mu-Mu    Mu-Mu    Mu-Mz   
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 23 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]