Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 MRI Database 
SEARCH FOR    
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
previous     16 - 20 (of 36)     next 
Na-Ne   Ne-Ne   Ne-No   No-No     Nu-Nu   Nu-Nu   Nu-Ny   Ny-Ny   
MRI Resources 
Jobs pool - Safety pool - Intraoperative MRI - Blood Flow Imaging - Liver Imaging - Journals
 
NoiseForum -
there are related threadsInfoSheet: - Artifacts -
Case Studies, 
Reduction Index, 
etc.
 
An undesirable background interference or disturbance that affects image quality.
The Noise is commonly characterized by the standard deviation of signal intensity in the image of a uniform object (phantom) in the absence of artifacts. The measured noise may depend on the particular phantom used due to variable effects on the Q of the receiver coil.
Noisy images appear when the SNR-Rate is too low - this is induced by the operator. Image artifacts and RF noise can often be caused by the presence and/or operation of a medical device in the MR environment. There are various noise sources in any electronic system, including Johnson noise, shot noise, thermal noise. Materials produce their own characteristic static magnetic field that can perturb the relationship between position and frequency essential to accurate image reconstruction.
RF noise, which often appears as static on the image, can be caused by a medical device located anywhere in the MR procedure room. RF noise is a result of excessive electromagnetic emissions from the medical device that interfere with the proper operation of the MR scanner. Since the MR procedure room is shielded from extraneous RF fields entering the room (Faraday cage), operation of electromagnetically noisy equipment outside the room does not typically affect the MR scanner.

See Signal to Noise Ratio and Radio Frequency Noise Artifact.
spacer

• View the NEWS results for 'Noise' (2).Open this link in a new window.

• View the DATABASE results for 'Noise' (86).Open this link in a new window

 
Further Reading:
  Basics:
Image Characteristics and Quality
   by www.sprawls.org    
  News & More:
Noise from Magnetic Resonance Imaging Can Have Short-Term Impact on Hearing
Thursday, 22 February 2018   by www.diagnosticimaging.com    
MRI Noise in Utero Not Harmful for Baby's Ears
Tuesday, 28 September 2010   by www.medgadget.com    
A Neural Mosaic Of Tones
Tuesday, 20 June 2006   by www.sciencedaily.com    
Noise Figure
 
A measure of the noise performance of an amplifier or chain of amplifiers such as a MR receiver. In MR systems the preamplifier should have a very low noise figure to prevent significant degradation of the signal to noise ratio of the MR signal. Noise figure is a ratio in dB's, and is given by: 20 log [Vo/(ViG)] where Vi is the input thermal noise voltage, Vo is the amplifier output noise level and G is the voltage gain of the amplifier (when the input and output impedance's of the amplifier are equal).
spacer

• View the DATABASE results for 'Noise Figure' (2).Open this link in a new window

MRI Resources 
Chemistry - MRI Technician and Technologist Jobs - Process Analysis - Bioinformatics - Absorption and Emission - RIS
 
Non-selective Pulse
 
This pulse affects all of the tissue within the transmitting coil. It is only used for MTC at a frequency distant from the Larmor frequency or if another method is selected to define slices like 3D acquisition.
spacer
Nonionic Intravenous Contrast AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Radiographic low-osmolar nonionic contrast agents have less side effects and fewer nephrotoxicity than ionic, high-osmolar agents. Gadolinium-based MRI contrast agents have a different formulation from iodinated X-ray contrast media, and there is no known cross sensitivity between these two types of contrast agents. Intravenous MRI contrast agents, specifically the gadolinium chelates have a high safety and lack of nephrotoxicity compared with X-ray contrast media.
The used gadolinium chelates differ in following properties: linear (e.g., gadodiamide and gadoversetamide have nonionic linear structures) vs. macrocyclic cores, and ionic vs. nonionic types. The nonionic molecules have lower osmolality and viscosity, which increase digestibility at greater concentrations, and make faster bolus injections conceivable. The macrocyclic molecules (e.g., gadoteridol has a nonionic macrocyclic ring structure) are more stable and show fewer tendencies to dissociate free Gd.

See also ProHance®, Omniscan®, OptiMARK®, Ionic Intravenous Contrast Agents.

See also the related poll result: 'MRI will have replaced 50% of x-ray exams by'
spacer

• View the DATABASE results for 'Nonionic Intravenous Contrast Agents' (4).Open this link in a new window

 
Further Reading:
  News & More:
Spurious Hypocalcemia After Omniscan- or OptiMARK-Enhanced Magnetic Resonance Imaging: An Algorithm for Minimizing a False-Positive Laboratory Value
   by arpa.allenpress.com    
Normalization Filter
 
This function equalizes the signal intensity when surface coils are used. By using this filter, the signal intensity of the region close to the coil is reduced, and the signal intensity of the area remote to the coil is increased. Also called homogeneity correction.
spacer
MRI Resources 
Guidance - MRI Technician and Technologist Schools - Claustrophobia - Liver Imaging - Open Directory Project - Examinations
 
previous       16 - 20 (of 36)      next 
Na-Ne   Ne-Ne   Ne-No    No-No    Nu-Nu   Nu-Nu   Nu-Ny   Ny-Ny   
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]