Field Even Echo Rephasing
 
The FEER method was the first clinically useful flow quantification method using phase effects, from which all spin phase related flow quantification techniques currently in use are derived.
In this sequence a gradient echo is measured after a gradient with flow compensation. The measured signal phase should be zero for all pixels. A deviation from gradient symmetry by shifting the gradient ramp slightly away from the symmetry condition will impart a defined phase shift to the magnetization vectors associated with spins from pixels with flow.
Slight stable variations in the magnetic field across the imaging volume will prevent the phase angle from being uniformly zero throughout the volume in the flow-compensated image. The first image (acquired without gradient shift) serves as reference, defining the values of all pixel phase angles in the flow (motion) compensated sequence. Ensuing images with gradient phase shifts imparted in each of the 3 spatial axes will then permit measurement of the 3 components of the velocity vector v = (vx, vy, vz) by calculating the respective phases px, py and pz by simply subtracting the pixel phases measured in the compensated image from the 3 images with a well defined velocity sensitization.
The determination of all 3 components of the velocity vector requires the measurement of 4 images.
The phase quantification requires an imaging time four times longer than the simple measurement of a phase image and associated magnitude image. If only one arbitrary flow direction is of interest, it suffices to acquire the reference image plus one image velocity sensitized in the arbitrary direction of interest.

See also Flow Quantification.
spacer
Searchterm 'Bit' was also found in the following services: 
spacer
Radiology  (21) Open this link in a new windowUltrasound  (22) Open this link in a new window
Image Contrast Characteristics
 
Variations in the value of TR and TE have an important effect on the control of image contrast characteristics.
Short values of TR (less than e.g. 1000 ms) and TE (less than e.g. 25 ms) are common in images exhibiting T1 contrast.
Long values of TR (greater than e.g. 1500 ms) and TE (greater than e.g.60 ms) are common in images exhibiting T2 contrast.
Middle TR values (e.g. from 1000 to 1500 ms) and middle TE values (e.g. from 25 to 60 ms) are common for density weighted contrast.
The values are depending on the field strength. TR is also a major factor in total scan time.
 
Images, Movies, Sliders:
 Knee MRI Coronal Pd Spir 001  Open this link in a new window
    
 Brain MRI Transversal T1 002  Open this link in a new window
    
 MRI Pancreas T2  Open this link in a new window
    
 Knee MRI Sagittal T1 004  Open this link in a new window
 Knee MRI Transverse 001  Open this link in a new window
 
Radiology-tip.comradContrast,  Low Contrast Detectability
spacer
Medical-Ultrasound-Imaging.comSonographic Features,  Echogenicity
spacer

• View the DATABASE results for 'Image Contrast Characteristics' (6).Open this link in a new window

 
Further Reading:
  Basics:
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Sunday, 1 August 2004   by www.ajronline.org    
IMAGE CONTRAST IN MRI(.pdf)
   by www.assaftal.com    
MRI Resources 
Collections - Liver Imaging - Mass Spectrometry - MRA - MRI Physics - Libraries
 
Byte
 
Eight bits.
spacer

• View the DATABASE results for 'Byte' (2).Open this link in a new window


• View the NEWS results for 'Byte' (2).Open this link in a new window.
 
Further Reading:
  Basics:
Byte
   by en.wikipedia.org    
Searchterm 'Bit' was also found in the following services: 
spacer
News  (35)  Resources  (8)  Forum  (11)  
 
Electromagnet
 
A type of magnet that utilizes coils of wire, typically wound on an iron core, so that as current flows through the coil it becomes magnetized. The direction of the magnetic field is parallel to the long axis of the coil. Whole body electromagnets, used in medical imaging (also called resistive) are limited to their field strength, because the weight becomes prohibitively large at high field MRI. The magnetic field shuts down, if the current is switched of. Because this type of magnet generates heat, a good cooling system is essential.
For a stronger magnetic field, the wires must be manufactured of superconducting materials to reduce the power needed to produce the field.

See also Resistive Magnet, Superconducting Magnet and Upright™ MRI
spacer

• View the DATABASE results for 'Electromagnet' (24).Open this link in a new window


• View the NEWS results for 'Electromagnet' (8).Open this link in a new window.
 
Further Reading:
  Basics:
What types of magnets are there?
   by my.execpc.com    
  News & More:
'Electromagnetic Wormhole' Possible with Invisibility Technology
Monday, 15 October 2007   by www.brightsurf.com    
Superconductors Face the Future
Wednesday, 15 September 2010   by www.nanotech-now.com    
Searchterm 'Bit' was also found in the following services: 
spacer
Radiology  (21) Open this link in a new windowUltrasound  (22) Open this link in a new window
Excelart AG™ with PianissimoInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
http://www.medical.toshiba.com/clinical/radiology/15texcelart.htm From Toshiba America Medical Systems Inc.;
the EXCELART is a superconducting whole body MRI system with a short wide-bore magnet, operating at 1.5 T. It features powerful high-speed gradients with a revolutionary gradient acoustic noise reduction system: Pianissimo. The dramatic reduction of gradient acoustic noise by Pianissimo greatly enhances patient comfort during exams. The standard array platform and a wide range of array coils ensure excellent images. A powerful 64-bit RISC-based computer system and newly developed array processor realize high productivity.
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Cylindrical Wide Short Bore
Opt. (WIP) Single and Multi Voxel
SYNCHRONIZATION
ECG: standard; peripheral: optional, respiratory gating
PULSE SEQUENCES
SE, FE, IR, FastSE, FastIR, FastFLAIR, Fast STIR, FastFE, FASE, Hybrid EPI, Multi Shot EPI; Angiography: 2D(gate/non-gate)/3D TOF, SORS-STC
IMAGING MODES
Single, multislice, volume study
TR
3.5-30000 msec
TE
8 msec min. SE; 1.2 msec min. FE
SINGLE/MULTI SLICE
less than 0.015 (256x256)
FOV
2 cm
1.0 min. 2-DFT: 0.2 min. 3-DFT
Up to 1024
MEASURING MATRIX
32-1024, phase;; 64-1024, freq.
PIXEL INTENSITY
256 gray levels
BORE DIAMETER
or W x H
65.5 cm, patient aperture
MAGNET WEIGHT
4050 kg (bare magnet incl. L-He)
H*W*D
235 x 219 x 199 cm
COOLING SYSTEM TYPE
Closed-loop water-cooled
CRYOGEN USE
Liquid helium: approx. less than 0.05 L/hr
STRENGTH
25 mT/m
5-GAUSS FRINGE FIELD
2.5 m / 4.0 m
Passive, active, auto-active
spacer

• View the DATABASE results for 'Excelart AG™ with Pianissimo' (2).Open this link in a new window

MRI Resources 
Implant and Prosthesis pool - Online Books - Case Studies - Shoulder MRI - Shielding - Guidance
 
previous      6 - 10 (of 34)     next
Result Pages : [1]  [2 3 4 5 6 7]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]