M
agnetic
R
esonance -
T
echnology
I
nformation
P
ortal
Welcome to MRI Technology
•
Database
Forum
News
Resources
Contact
Info
Sheets
Artifacts
Coils
Contrast Agents
Devices
MRI Safety
Sequences
Images
Sliders
Abbreviations
Acronyms
Protocols
Patient
Information
Out-
side
Congresses
Resources
See a comprehensive list of contrast agents!
From Abdoscan® to Teslascan®.
'Blips'
SEARCH FOR
search it again
Blips
2
3
5
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
Result : Searchterm
'
Blips
'
found in
1
term [
] and
2
definitions [
]
1 - 3
(of 3)
Result Pages :
[
1
]
MRI Resources
Knee MRI
-
Pediatric and Fetal MRI
-
MR Guided Interventions
-
Directories
-
Devices
-
Raman Spectroscopy
Blips
Name for the
phase encoding
top of the EPI sequence.
•
Share the entry '
Blips
':
MRI Resources
Veterinary MRI
-
Cardiovascular Imaging
-
Used and Refurbished MRI Equipment
-
Knee MRI
-
Brain MRI
-
Spectroscopy
Blipped Echo Planar Imaging
See
Echo Planar Imaging
and
Blips
.
Further Reading:
News & More:
New Imaging Method Makes Brain Scans 7 Times Faster
Sunday, 9 January 2011
by
www.dailytech.com
MRI Resources
Case Studies
-
Software
-
Services and Supplies
-
MRI Physics
-
Non-English
-
Movies
Blipped Phase Encoding
A strategy for incrementing the position of the
k-space trajectory
of an
echo planar imaging
(EPI)
pulse sequence
.
Echo planar imaging
(EPI) uses a constant
gradient
amplitude
in one direction. This, combined with an
oscillating gradient system
in the
frequency encoding
direction, produces a zigzag trajectory in
k-space
. In the blipped
phase encoding
variant of EPI, the
k-space
position in the
phase
encoded direction is incremented by
gradient
'
blips
' of the appropriate area. These, when timed to occur during the reversals of the read-out
gradient
, produce a rectilinear path in
k-space
.
The artifacts in an EPI image can arise from both
hardware
and sample imperfections. These are most easily understandable from examination of the
k-space trajectory
involved, which is either a zigzag form (when using a constant
phase encoding gradient
) or a rastered zigzag (when the
phase encoding
is performed with small gradients at the end of each scan line, so-called 'blipped' EPI).
Further Reading:
Basics:
Chapter 2 - Principles of Magnetic Resonance Imaging
by
www.fmrib.ox.ac.uk
MRI Resources
Raman Spectroscopy
-
MRI Physics
-
Databases
-
Lung Imaging
-
Supplies
-
Contrast Agents
1 - 3
(of 3)
Result Pages :
[
1
]
Random Page
top
Share This Page
MR-TIP
Community
User
Pass
Register (free)
Member
Services
New acceleration techniques will
:
reduce scan times
cause artifacts
increase expenses
be useful if you have a lot of experience
doesn't do much
never heard of
Contribute
Results
Look
Ups
Greeks
Symbols
Units & M.
Radiology
Ultrasound
MRI
Give MR-TIP a Feedback
Help Page
Submit a
Link/Resource
(login or register first)
MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.
Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP •
Radiology-TIP
•
Medical-Ultrasound-Imaging
•
Copyright © 2003 - 2024
SoftWays
. All rights reserved. [ 21 November 2024]
Terms of Use
|
Privacy Policy
|
Advertising
[last update: 2024-02-26 03:41:00]