Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Breast MRI' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Breast MRI' found in 2 terms [] and 11 definitions [], (+ 15 Boolean[] results
1 - 5 (of 28)     next
Result Pages : [1]  [2 3]  [4 5 6]
Searchterm 'Breast MRI' was also found in the following services: 
spacer
News  (99)  Resources  (23)  Forum  (4)  
 
Breast MRIMRI Resource Directory:
 - Breast MRI -
 
(MR mammography) Magnetic resonance imaging of the breast is particularly useful in evaluation of newly diagnosed breast cancer, in women whose breast tissue is mammographically very dense and for screening in women with a high lifetime risk of breast cancer because of their family history or genetic disposition.
Breast MRI can be performed on all standard whole body magnets at a field strength of 0.5 T - 1.5 Tesla. Powerful gradient strengths over 15 mT/m will help to improve the balance between spatial resolution, scanning speed, and volume coverage. The use of a dedicated bilateral breast coil is obligatory.
Malignant lesions release angiogenic factors that increase local vessel density and vessel permeability. Breast cancer is detectable due to the strong enhancement in dynamic breast imaging that peaks early (about 1-2 min.) after contrast medium injection. If breast cancer is suspected, a breast biopsy may be necessary to secure the diagnosis.

See also Magnetic Resonance Imaging MRI, Biopsy and MR Guided Interventions.

Requirements in breast MRI procedures:
Both breasts must be measured without gaps.
Temporal resolution should be sufficient to allow early imaging after contrast agent with dynamic imaging every 60-120 sec.
For the best possible detection of enhancement fat signal should be eliminated either by image subtraction or by spectrally selective fat saturation.
Thin slices are necessary to assure absence of partial volume effects.
Imaging should be performed with a spatial resolution in plane less than 1 mm.

For Ultrasound Imaging (USI) see Breast Ultrasound at Medical-Ultrasound-Imaging.com.

See also the related poll result: 'MRI will have replaced 50% of x-ray exams by'
 
Images, Movies, Sliders:
 Breast MRI Images T2 And T1  Open this link in a new window
      
 Breast MRI Images T2 And T1 Pre - Post Contrast  Open this link in a new window
 Breast MRI Images T1 Pre - Post Contrast  Open this link in a new window
      
 
Radiology-tip.comradMammography,  Breast Imaging
spacer
Medical-Ultrasound-Imaging.comBreast Ultrasound
spacer
 
• Share the entry 'Breast MRI':  Facebook  Twitter  LinkedIn  
 
• Related Searches:
    • Contrast Medium
    • Contrast Enhanced MRI
    • Gadolinium
    • Computer Aided Detection
    • Postprocessing
 
Further Reading:
  Basics:
New Screening Guidelines for Women at High Risk for Breast Cancer
Wednesday, 26 September 2007   by www.newswise.com    
CONTRAST-ENHANCED MRI OF THE BREAST(.pdf)
MRI Improves Breast Cancer Screening in Older BRCA Carriers
Monday, 5 January 2015   by www.cancernetwork.com    
  News & More:
Technology advances in breast cancer screenings lead to early diagnosis
Friday, 6 October 2023   by ksltv.com    
Are synthetic contrast-enhanced breast MRI images as good as the real thing?
Friday, 18 November 2022   by healthimaging.com    
Abbreviated breast MRI protocols not as cost-effective as promised, new study shows
Wednesday, 20 July 2022   by healthimaging.com    
Deep learning poised to improve breast cancer imaging
Thursday, 24 February 2022   by www.eurekalert.org    
Pre-Operative Breast MRI Can Help Identify Patients Likely to Experience Nipple-Sparing Mastectomy Risks
Wednesday, 7 April 2021   by www.diagnosticimaging.com    
Breast cancer screening recalls: simple MRI measurement could avoid 30% of biopsies
Monday, 1 March 2021   by www.eurekalert.org    
A Comparison of Methods for High-Spatial-Resolution Diffusion-weighted Imaging in Breast MRI
Tuesday, 25 August 2020   by pubs.rsna.org    
Pre-Operative Breast MRI Diagnoses More Cancers in Women with DCIS
Thursday, 9 July 2020   by www.diagnosticimaging.com    
Breast MRI and tumour biology predict axillary lymph node response to neoadjuvant chemotherapy for breast cancer
Thursday, 26 December 2019   by cancerimagingjournal.biomedcentral.com    
Breast MRI Coding Gets an Overhaul in 2019
Wednesday, 9 January 2019   by www.aapc.com    
How accurate are volumetric software programs when compared to breast MRI?
Thursday, 27 July 2017   by www.radiologybusiness.com    
Additional Breast Cancer Tumors Found on MRI After Mammography May Be Larger, More Aggressive
Wednesday, 9 December 2015   by www.oncologynurseadvisor.com    
Preoperative MRI May Overdiagnose Contralateral Breast Cancer
Wednesday, 2 December 2015   by www.cancertherapyadvisor.com    
BI-RADS and breast MRI useful in predicting malignancy
Wednesday, 30 May 2012   by www.oncologynurseadvisor.com    
Searchterm 'Breast MRI' was also found in the following service: 
spacer
Radiology  (3) Open this link in a new window
Aurora® 1.5T Dedicated Breast MRI SystemInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.
 
www.auroramri.com/mri/product/ From Aurora Imaging Technology, Inc.;
The Aurora® 1.5T Dedicated Breast MRI System with Bilateral SpiralRODEO™ is the first and only FDA approved MRI device designed specifically for breast imaging. The Aurora System, which is already in clinical use at a growing number of leading breast care centers in the US, Europe, got in December 2006 also the approval from the State Food and Drug Administration of the People's Republic of China (SFDA).
'Some of the proprietary and distinguishing features of the Aurora System include: 1) an ellipsoid magnetic shim that provides coverage of both breasts, the chest wall and bilateral axillary lymph nodes; 2) a precision gradient coil with the high linearity required for high resolution spiral reconstruction;; 3) a patient-handling table that provides patient comfort and procedural utility; 4) a fully integrated Interventional System for MRI guided biopsy and localization; and 5) the user-friendly AuroraCAD™ computer-aided image display system designed to improve the accuracy and efficiency of diagnostic interpretations.'
Device Information and Specification
CLINICAL APPLICATION
CONFIGURATION
Short bore compact
IMAGING MODES
Bi-lateral RODEO fat suppression, high resolution Rotating Delivery of Excitation Offresonance Spiral, integrated targeting SW compatible with major MR guided intervention equipment
TR
10 ms for gradient echo and less than 2,500 ms for T2 weighted spin echo
TE
From 5 ms for RODEO Plus to over 80 ms, 120 ms for T2 sequences
SINGLE/MULTI SLICE
Around 0.02 sec for a 256x256 image, 12.4 sec for a 512 x 512 x 32 multislice set
FOV
20 - 36 cm, max. elliptical 36 x 44 cm
MEASURING MATRIX
512 x 512
BORE DIAMETER
or W x H
64 cm diameter (gantry)
MAGNET WEIGHT
8,500 lbs
H*W*D
240 x 188 x 163 cm
POWER REQUIREMENTS
150A/120V-208Y/3 Phase//60 Hz/5 Wire
COOLING SYSTEM
Helium for magnet, distilled/de-ionized water for coil;
spacer

• View the DATABASE results for 'Aurora® 1.5T Dedicated Breast MRI System' (2).Open this link in a new window


• View the NEWS results for 'Aurora® 1.5T Dedicated Breast MRI System' (3).Open this link in a new window.
 
Further Reading:
  News & More:
Aurora Imaging Technology Announces Approval in China
   by salesandmarketingnetwork.com    
Aurora Imaging Technology, Inc. Release: Results of a Multi-Center Trial Demonstrates Superior Diagnostic Performance of the Aurora® 1.5T Dedicated Breast MRI System Over Whole-Body Breast MRI
Monday, 1 October 2012   by www.biospace.com    
MRI Resources 
Image Quality - Homepages - Anatomy - MRI Technician and Technologist Career - Stimulator pool - Brain MRI
 
Biopsy
 
MRI guided biopsies are usually performed for lesions that are found on for example liver or breast MRI procedures and that are not seen on computed tomography, ultrasonography or mammography. The identification of cancer on breast MRI is dependent on uptake of intravenous contrast agents.
First an MRI scan, using a dedicated breast coil and biopsy guidance system is performed to found the lesion. After skin disinfection and local anesthesia, the biopsy procedure starts. Possible MR guided interventions include fine needle aspiration, core needle biopsy and vacuum-assisted biopsy (VABB) to sample tissue from the lesion; or wire localization prior to surgery for lesions that are not palpable.

See also Breast MRI.
spacer

• View the DATABASE results for 'Biopsy' (10).Open this link in a new window


• View the NEWS results for 'Biopsy' (6).Open this link in a new window.
 
Further Reading:
  Basics:
Specimen radiography confirms success of MRI-guided breast biopsy
Friday, 11 August 2006   by www.eurekalert.org    
Physics of MRI Safety
   by www.aapm.org    
  News & More:
FDA Clears MRI-Compatible Robotics System for Breast Biopsy
Thursday, 14 September 2023   by www.diagnosticimaging.com    
Clinical trial: Using MRI for prostate cancer diagnosis equals or beats current standard
Thursday, 4 February 2021   by www.eurekalert.org    
The effects of incidental findings from whole-body MRI on the frequency of biopsies and detected malignancies or benign conditions in a general population cohort study
Sunday, 30 August 2020   by link.springer.com    
Magnetic Resonance Imaging Guided Confirmatory Biopsy for Initiating Active Surveillance of Prostate Cancer
Wednesday, 11 September 2019   by jamanetwork.com    
Siemens, U. of Twente Biopsy Robot Promises Greater Precision, Less Cost
Friday, 22 January 2016   by www.meddeviceonline.com    
Combination of MRI and PET imaging techniques can prevent second breast biopsy
Sunday, 29 June 2014   by www.news-medical.net    
Searchterm 'Breast MRI' was also found in the following services: 
spacer
News  (99)  Resources  (23)  Forum  (4)  
 
Computer Aided Detection
 
(CAD) 'Computer aided detection' or 'computer assisted diagnosis' systems are tools to improve the efficiency and workflow in medical imaging procedures. The aim of CAD is to increase the diagnostic accuracy of screening procedures by using a computer system to locate abnormalities, improve image management, correct patient movement and assist the radiologists in the interpretation and analysis of data-intensive studies. Typical applications include the tumor detection in mammography, breast MRI, colonography, and lung imaging. Newer applications like prostate MRI are under investigation.

See also MR Guided Interventions, Breast MRI and Hybrid Imaging.
spacer

• View the DATABASE results for 'Computer Aided Detection' (3).Open this link in a new window


• View the NEWS results for 'Computer Aided Detection' (7).Open this link in a new window.
 
Further Reading:
  News & More:
Evaluating brain MRI scans with the help of artificial intelligence
Thursday, 2 June 2022   by www.technologyreview.com    
New AI Tool for Prostate MRI Analysis to Support PI-RADS Scoring
Monday, 11 April 2022   by www.itnonline.com    
Superhuman 20 second AI heart tool begins NHS roll-out
Friday, 11 March 2022   by www.bhf.org.uk    
Computer-aided detection and diagnosis for prostate cancer based on mono and multi-parametric MRI: A review - Abstract
Tuesday, 28 April 2015   by urotoday.com    
MRI method for measuring MS progression validated
Thursday, 19 December 2013   by www.eurekalert.org    
Searchterm 'Breast MRI' was also found in the following service: 
spacer
Radiology  (3) Open this link in a new window
Contrast Enhanced MRIInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Enhanced MRI -
 
Contrast enhanced MRI is a commonly used procedure in magnetic resonance imaging. The need to more accurately characterize different types of lesions and to detect all malignant lesions is the main reason for the use of intravenous contrast agents.
Some methods are available to improve the contrast of different tissues. The focus of dynamic contrast enhanced MRI (DCE-MRI) is on contrast kinetics with demands for spatial resolution dependent on the application. DCE-MR imaging is used for diagnosis of cancer (see also liver imaging, abdominal imaging, breast MRI, dynamic scanning) as well as for diagnosis of cardiac infarction (see perfusion imaging, cardiac MRI). Quantitative DCE-MRI requires special data acquisition techniques and analysis software.
Contrast enhanced magnetic resonance angiography (CE-MRA) allows the visualization of vessels and the temporal resolution provides a separation of arteries and veins. These methods share the need for acquisition methods with high temporal and spatial resolution.
Double contrast administration (combined contrast enhanced (CCE) MRI) uses two contrast agents with complementary mechanisms e.g., superparamagnetic iron oxide to darken the background liver and gadolinium to brighten the vessels. A variety of different categories of contrast agents are currently available for clinical use.
Reasons for the use of contrast agents in MRI scans are:
Relaxation characteristics of normal and pathologic tissues are not always different enough to produce obvious differences in signal intensity.
Pathology that is sometimes occult on unenhanced images becomes obvious in the presence of contrast.
Enhancement significantly increases MRI sensitivity.
In addition to improving delineation between normal and abnormal tissues, the pattern of contrast enhancement can improve diagnostic specificity by facilitating characterization of the lesion(s) in question.
Contrast can yield physiologic and functional information in addition to lesion delineation.
Imaging of arteries and veins with contrast enhanced angiography (CE MRA).

Common Indications:
Brain MRI : Preoperative/pretreatment evaluation and postoperative evaluation of brain tumor therapy, CNS infections, noninfectious inflammatory disease and meningeal disease.
Spine MRI : Infection/inflammatory disease, primary tumors, drop metastases, initial evaluation of syrinx, postoperative evaluation of the lumbar spine: disk vs. scar.
Breast MRI : Detection of breast cancer in case of dense breasts, implants, malignant lymph nodes, or scarring after treatment for breast cancer, diagnosis of a suspicious breast lesion in order to avoid biopsy.

For Ultrasound Imaging (USI) see Contrast Enhanced Ultrasound at Medical-Ultrasound-Imaging.com. See also Blood Pool Agents, Myocardial Late Enhancement, Cardiovascular Imaging, Contrast Enhanced MR Venography, Contrast Resolution, Dynamic Scanning, Lung Imaging, Hepatobiliary Contrast Agents, Contrast Medium and MRI Guided Biopsy.
 
Images, Movies, Sliders:
 Delayed Myocardial Contrast Enhancement from Infarct  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 Left Circumflex Ischemia First-pass Contrast Enhancement  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 Normal Lung Gd Perfusion MRI  Open this link in a new window
 MRI of the Brain Stem with Temoral Bone and Auditory System  Open this link in a new window
    
SlidersSliders Overview

 Breast MRI Images T1 Pre - Post Contrast  Open this link in a new window
 
Radiology-tip.comradContrast Enhanced Computed Tomography
spacer
Medical-Ultrasound-Imaging.comContrast Enhanced Ultrasound,  Contrast Enhanced Doppler Imaging
spacer

• View the DATABASE results for 'Contrast Enhanced MRI' (14).Open this link in a new window


• View the NEWS results for 'Contrast Enhanced MRI' (8).Open this link in a new window.
 
Further Reading:
  Basics:
Optimal k-Space Sampling for Dynamic Contrast-Enhanced MRI with an Application to MR Renography
Thursday, 5 November 2009   by www.ncbi.nlm.nih.gov    
  News & More:
FDA Approves Gadopiclenol for Contrast-Enhanced Magnetic Resonance Imaging
Tuesday, 27 September 2022   by www.pharmacytimes.com    
Effect of gadolinium-based contrast agent on breast diffusion-tensor imaging
Thursday, 6 August 2020   by www.eurekalert.org    
Artificial Intelligence Processes Provide Solutions to Gadolinium Retention Concerns
Thursday, 30 January 2020   by www.itnonline.com    
Accuracy of Unenhanced MRI in the Detection of New Brain Lesions in Multiple Sclerosis
Tuesday, 12 March 2019   by pubs.rsna.org    
The Effects of Breathing Motion on DCE-MRI Images: Phantom Studies Simulating Respiratory Motion to Compare CAIPIRINHA-VIBE, Radial-VIBE, and Conventional VIBE
Tuesday, 7 February 2017   by www.kjronline.org    
Novel Imaging Technique Improves Prostate Cancer Detection
Tuesday, 6 January 2015   by health.ucsd.edu    
New oxygen-enhanced MRI scan 'helps identify most dangerous tumours'
Thursday, 10 December 2015   by www.dailymail.co.uk    
All-organic MRI Contrast Agent Tested In Mice
Monday, 24 September 2012   by cen.acs.org    
A groundbreaking new graphene-based MRI contrast agent
Friday, 8 June 2012   by www.nanowerk.com    
MRI Resources 
Developers - Jobs pool - Safety Training - Collections - Anatomy - Pregnancy
 
     1 - 5 (of 28)     next
Result Pages : [1]  [2 3]  [4 5 6]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]