Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'DWI' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'DWI' found in 1 term [] and 40 definitions []
previous     16 - 20 (of 41)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9]
Searchterm 'DWI' was also found in the following services: 
spacer
News  (47)  Resources  (15)  Forum  (27)  
 
Water Fat ShiftForum -
related threads
 
(WFS) The water fat shift defines the frequency bandwidth resulting in pixel shift due to the water/fat spectral separation. WFS decreases or increases to a specified number of pixels in mm. The amount of WFS is proportional to the main magnetic field.

See Bandwidth.
 
Images, Movies, Sliders:
 MRI Liver Out Of Phase  Open this link in a new window
    
 
spacer
 
• Related Searches:
    • Black Boundary Artifact
    • Contrast to Noise Ratio
    • In Phase
    • Bandwidth
    • Fat Suppression
 
Further Reading:
  Basics:
Bandwidth
   by en.wikipedia.org    
MRI Resources 
MRCP - Collections - Directories - Guidance - Mobile MRI - Pacemaker
 
AIRIS IIâ„¢InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.hitachimed.com/products/airis_2.asp From Hitachi Medical Systems America Inc.;
the AIRIS II, an entry in the diagnostic category of open MR systems, was designed by Hitachi Medical Systems America Inc. (Twinsburg, OH, USA) and Hitachi Medical Corp. (Tokyo) and is manufactured by the Tokyo branch. A 0.3 T field-strength magnet and phased array coils deliver high image quality without the need for a tunnel-type high-field system, thereby significantly improving patient comfort not only for claustrophobic patients.
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Vertical Field, Open MRI
QD Head, MA Head and Neck, QD C-Spine, MA or QD Shoulder, MA CTL Spine, QD Knee, Neck, QD TMJ, QD Breast, QD Flex Body (4 sizes), Small and Large Extrem., QD Wrist, MA Foot and Ankle (WIP), PVA (WIP)
SYNCHRONIZATION
Cardiac gating, ECG/peripheral, respiratory gating (2 modes)
PULSE SEQUENCES
SE, GE, GR, IR, FIR, STIR, FSE, ss-FSE, FLAIR, EPI -DWI, SE-EPI, ms - EPI, SSP, MTC, SARGE, RSSG, TRSG, MRCP, Angiography: CE, 2D/3D TOF
IMAGING MODES
Single, multislice, volume study
TR
SE: 30 - 10,000msec GE: 20 - 10,000msec IR: 50 - 16,700msec FSE: 200 - 16,7000msec
TE
SE : 10 - 250msec IR: 10 -250msec GE: 5 - 50 msec FSE: 15 - 2,000
SINGLE/MULTI SLICE
0.05 sec/image (256 x 256)
FOV
5cm to 42 cm continuous
2D: 2 - 100 mm; 3D: 0.5 - 5 mm
1280 x 1024
MEASURING MATRIX
512 x 512
PIXEL INTENSITY
Level Range: -2,000 to +4,000
Sub millimeter
MAGNET TYPE
Self-shielded, permanent
BORE DIAMETER
or W x H
110 x 43 cm
MAGNET WEIGHT
15,700 kg
H*W*D
79 x 111 x 73 cm
POWER REQUIREMENTS
208/220/240 V, single phase
COOLING SYSTEM TYPE
Air-cooled
STRENGTH
15 mT/m
2.0 m lateral, 2.5 m vert./long
Auto shimming, 3-axis/patient, and volume shim
spacer

• View the DATABASE results for 'AIRIS II™' (2).Open this link in a new window

MRI Resources 
Software - Guidance - Colonography - Knee MRI - MRI Training Courses - General
 
Altaireâ„¢InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.hitachimed.com/products/altaire.asp From Hitachi Medical Systems America, Inc.;
the AIRIS made its debut in 1995. Hitachi followed up with the AIRIS II system, which has proven equally successfully. 'All told, Hitachi has installed more than 1,000 MRI systems in the U.S., holding more than 17 percent of the total U.S. MRI installed base, and more than half of the installed base of open MR systems,' says Antonio Garcia, Frost and Sullivan industry research analyst. Now Altaire employs a blend of innovative Hitachi features called VOSIâ„¢ technology, optimizing each sub-system's performance in concert with the other sub-systems, to give the seamless mix of high-field performance and the patient comfort, especially for claustrophobic patients, of open MR systems.

Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Vertical Field, Open MRI
DualQuad T/R Body Coil, MA Head, MA C-Spine, MA Shoulder, MA Wrist, MA CTL Spine, MA Knee, MA TMJ, MA Flex Body (3 sizes), Neck, small and large Extremity, PVA (WIP), Breast (WIP), Neurovascular (WIP), Cardiac (WIP) and MA Foot//Ankle (WIP)
SYNCHRONIZATION
Cardiac gating, ECG/peripheral, respiratory gating (2 modes)
PULSE SEQUENCES
SE, GE, GR, IR, FIR, STIR, ss-FSE, FSE, DE-FSE/FIR, FLAIR, ss/ms-EPI, ss/ms EPI- DWI, SSP, MTC, SE/GE-EPI, MRCP, SARGE, RSSG, TRSG, BASG, Angiography: CE, PC, 2D/3D TOF
IMAGING MODES
Single, multislice, volume study
TR
SE: 30 - 10,000msec GE: 3.6 - 10,000msec IR: 50 - 16,700msec FSE: 200 - 16,7000msec
TE
SE : 8 - 250msec IR: 5.2 -7,680msec GE: 1.8 - 2,000 msec FSE: 5.2 - 7,680
SINGLE/MULTI SLICE
0.05 sec/image (256 x 256)
FOV
5cm to 45 cm continuous
2D: 2 - 100 mm; 3D: 0.5 - 5 mm
1280 x 1024
MEASURING MATRIX
512 x 512
PIXEL INTENSITY
Level Range: -2,000 to +4,000
Sub millimeter
MAGNET TYPE
Self-shielded, superconducting
BORE DIAMETER
or W x H
110 x 43 cm
MAGNET WEIGHT
41,700 kg
H*W*D
256 x 348 x 236 cm
POWER REQUIREMENTS
208 V +/- 10%, 3 phase
COOLING SYSTEM TYPE
Water-cooled
STRENGTH
22 mT/m
3.1 m lateral, 3.6 m vertical
Auto shimming, 3-axis/patient and active shimming
spacer

• View the DATABASE results for 'Altaire™' (2).Open this link in a new window

 
Further Reading:
  News & More:
Altaire High-Field Open MRI(.pdf)
2001
Searchterm 'DWI' was also found in the following services: 
spacer
News  (47)  Resources  (15)  Forum  (27)  
 
Anti Aliasing
 
Anti aliasing is a method to prevent aliasing artifacts by properly choosing the sampling rate. The signal is sampled at a higher bandwidth than required.

See Oversampling.
spacer
MRI Resources 
Veterinary MRI - MRI Training Courses - Diffusion Weighted Imaging - Functional MRI - MR Myelography - Blood Flow Imaging
 
Bracco Diagnostics, Inc.MRI Resource Directory:
 - Manufacturers -
 
www.bdi.bracco.com The company is a member of the Bracco Group, a highly innovative healthcare group and world leader in global integrated solutions for the diagnostic medical imaging field. The Bracco Group is headquartered in Milan, Italy. Its North American operations consist of Bracco Diagnostics and Bracco Research USA, both located in Princeton, New Jersey. Bracco Diagnostics is one of the fastest growing developers and marketers of diagnostic pharmaceuticals in North America, with products for various imaging applications, including Isovue® (iopamidol - X-ray contrast agent), ProHance® (gadoteridol - MRI contrast agent), SonoVue® (ultrasound contrast agent) and nuclear medicine products.
Gadoteridol has been available in Europe and the USA for several years. Holder of the Marketing Authorization: Bracco International B.V. - Strawinskylaan 3051 - 1077 ZX Amsterdam The Netherlands. (Contact: Kirk Deeter, Phone: +NL-303-838-8708)

MRI Contrast Agents:
•
•
•
•
Contact Information
Please see Bracco Diagnostics, Inc.'s
spacer

• View the DATABASE results for 'Bracco Diagnostics, Inc.' (2).Open this link in a new window

 
Further Reading:
  News & More:
FDA Expands Pediatric Age Range for MultiHance Contrast Agent
Tuesday, 30 January 2018   by www.empr.com    
BRACCO DIAGNOSTICS' MULTIHANCE EARNS FDA APPROVAL
Wednesday, 24 November 2004   by salesandmarketingnetwork.com    
MRI Resources 
MRI Centers - Absorption and Emission - Cardiovascular Imaging - Process Analysis - Functional MRI - Safety pool
 
previous      16 - 20 (of 41)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]