Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Equilibrium' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Equilibrium' found in 7 terms [] and 29 definitions []
1 - 5 (of 36)     next
Result Pages : [1 2]  [3 4 5 6 7 8]
Searchterm 'Equilibrium' was also found in the following services: 
spacer
Resources  (1)  
 
Equilibrium
 
A state of balance that exists between two opposing forces or divergent forms of influence.
spacer
 
• Share the entry 'Equilibrium':  Facebook  Twitter  LinkedIn  
 
Further Reading:
  News & More:
Improved shim method based on the minimization of the maximum off-resonance frequency for balanced SSFP
Monday, 1 June 2009   by www.ncbi.nlm.nih.gov    
Searchterm 'Equilibrium' was also found in the following service: 
spacer
Radiology  (3) Open this link in a new window
Driven EquilibriumInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
In fast imaging sequences driven equilibrium sensitizes the sequence to variations in T2. This MRI technique turns transverse magnetization Mxy to the longitudinal axis using a pulse rather than waiting for T1 relaxation.
The first two pulses form a spin echo and, at the peak of the echo, a second 90° pulse returns the magnetization to the z-axis in preparation for a fresh sequence. In the absence of T2 relaxation, then all the magnetization can be returned to the z-axis. Otherwise, T2 signal loss during the sequence will reduce the final z-magnetization.
The advantage of this sequence type is, that both longitudinal and also transverse magnetization are back to equilibrium in a shorter amount of time. Therefore, contrast and signal can be increased while using a shorter TR. This pulse type can be applied to other sequences like FSE, GE or IR.

Sequences with driven equilibrium:
Driven Equilibrium Fast Gradient Recalled acquisition in the steady state - DE FGR,
Driven Equilibrium Fourier Transformation - DEFT,
Driven Equilibrium magnetization preparation - DE prep,
Driven Equilibrium Fast Spin Echo - DE FSE.
 
Images, Movies, Sliders:
 MRI of the Skull Base  Open this link in a new window
    
SlidersSliders Overview

 
spacer

• View the DATABASE results for 'Driven Equilibrium' (8).Open this link in a new window

 
Further Reading:
  Basics:
3D Turbo Spin-Echo Sequence with Motion-Sensitized Driven-Equilibrium Preparation for Detection of Brain Metastases on 3T MR Imaging
Saturday, 3 December 2011   by www.ajnr.org    
  News & More:
Advances in high-field MR imaging of the spine
Wednesday, 5 August 2009   by www.appliedradiology.com    
Comparison of New Methods for Magnetic Resonance Imaging of Articular Cartilage(.pdf)
2002
MRI Resources 
Artifacts - Open Directory Project - Safety pool - - Pacemaker - Devices
 
Thermal Equilibrium
 
A state in which all parts of a system are at the same effective temperature, in particular where the relative alignment of the spins with the magnetic field is determined solely by the thermal energy of the system (in which case the relative numbers of spins with different alignments will be given by the Boltzmann distribution).
spacer

• View the DATABASE results for 'Thermal Equilibrium' (3).Open this link in a new window

 
Further Reading:
  News & More:
Evaluation of Absorbed Dose by MRI Read-Out
Saturday, 18 November 2017   by www.jstage.jst.go.jp    
Searchterm 'Equilibrium' was also found in the following services: 
spacer
Resources  (1)  
 
Driven Equilibrium Fast Spin EchoInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(DE FSE) A fast spin echo sequence with application of a pulse, which sensitizes the sequence to variations in T2.
 
Images, Movies, Sliders:
 MRI of the Skull Base  Open this link in a new window
    
SlidersSliders Overview

 
spacer
 
Further Reading:
  News & More:
Metal Artefact Reduction
Thursday, 9 June 2011   by www.revisemri.com    
Searchterm 'Equilibrium' was also found in the following service: 
spacer
Radiology  (3) Open this link in a new window
Driven Equilibrium Fourier TransformationInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(DEFT) This sequence enhances fluid signal by using a 'tip-up' pulse following a spin echo train.
See Driven Equilibrium and Fourier Transformation Imaging.
spacer
MRI Resources 
Education - Veterinary MRI - Fluorescence - Stent - MRI Physics - Research Labs
 
     1 - 5 (of 36)     next
Result Pages : [1 2]  [3 4 5 6 7 8]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 20 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]