GastroMARK® belongs to the negative oral contrast agents (same as Lumirem®, another brand name for ferumoxsil). GastroMARK® is used to distinguish the loops of the bowel from other abdominal structures and physiology. When GastroMARK® is ingested, it flows through and darkens the stomach and the small intestine in 30 to 45 minutes. By more clearly identifying the intestinal loops, GastroMARK® improves visualization of adjacent abdominal tissues such as the pancreas.
Drug Information and Specification
PHARMACOKINETIC
Gastrointestinal
OSMOLALITY
250 mosm/kgH2O
CONCENTRATION
52.5mg Fe/300mL
PREPARATION
Finished product
DEVELOPMENT STAGE
For sale
PRESENTATION
Bottles containing 300 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING
PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT STAGE
DISTRIBUTOR
USA
GastroMARK®
For sale
| | | | | Further Reading: | Basics:
|
|
| |
| | | Searchterm 'Flow' was also found in the following services: | | | | |
| | |
| |
|
Quick Overview
REASON
Motion, heartbeat, respiration
HELP
Triggering, breath hold, pharmaceuticals to reduce bowel motion
Ghosting artifacts are in the most cases caused by movements (e.g., respiratory motion, bowel motion, arterial pulsations, swallowing, and heartbeat) and appear in the phase encoding direction.
Image Guidance
| | | | • View the DATABASE results for 'Ghosting Artifact' (5).
| | | | Further Reading: | Basics:
|
|
| |
| | | | | |
| |
|
Flow and motion artifacts are rotated about 90°, caused by the exchange of phase and frequency encoding direction. That prevents artifacts from hiding structures of interest. | | | | | |
| | | Searchterm 'Flow' was also found in the following services: | | | | |
| | |
| |
|
A Helmholtz pair consists of two identical circular magnetic coils that are placed symmetrically one on each side of the experimental area along a common axis, and separated by a distance equal to the radius of the coil. Actually, a slightly larger separation improves the field uniformity. Each coil carries an equal electrical current flowing in the same direction. A cylindrical region extending between the centers of the two coils and approximately 1/5 of their diameter will have a nearly spatially uniform magnetic field.
In MRI, the Helmholtz pair coils are used as z- gradient coils to produce linear variations in the main magnetic field along the z-axis. Also in use as z- gradient coils are the Maxwell coils (three coils in a slightly more complicated geometry than the Helmholtz configuration). These coils are only occasionally used as RF coils for imaging. | | | | • View the DATABASE results for 'Helmholtz Pair Coil' (2).
| | | | Further Reading: | | Basics:
|
|
News & More:
| |
| |
| | | Searchterm 'Flow' was also found in the following services: | | | | |
| | |
| |
|
Material that inhibits the flow of electricity. | | | | • View the DATABASE results for 'Insulator' (2).
| | | | |
| | | | |
| | | |
|
| |