Resonance Offset
 
Either the phase due to an applied field or field inhomogeneity and generated during the time between two RF pulses, or the phase change of the RF pulse from one pulse to the next.
spacer
Searchterm 'Homogeneity' was also found in the following services: 
spacer
Radiology  (2) Open this link in a new windowUltrasound  (1) Open this link in a new window
Saddle CoilInfoSheet: - Coils - 
Intro, 
Overview, 
etc.MRI Resource Directory:
 - Coils -
 
A saddle coil has a cylindrical body, with one or more turns of wire (older versions) or foil (newer versions) on each side. It generates a very homogenous field in the direction of its long axis. To achieve a higher B1 homogeneity there are different developments like Folded Litz-foil Saddle Coils or Etched Litz-foil Saddle Coils.

See also the related poll result: '3rd party coils are better than the original manufacturer coils'
spacer

• View the DATABASE results for 'Saddle Coil' (6).Open this link in a new window

 
Further Reading:
  Basics:
Imaging Hardware
   by www.fmrib.ox.ac.uk    
MRI Resources 
Process Analysis - Health - Supplies - Cardiovascular Imaging - Nerve Stimulator - MRA
 
Sensitive Volume
 
Region of the object from which NMR signal will preferentially be acquired because of strong magnetic field inhomogeneity elsewhere. Effect can be enhanced by use of a shaped RF field that is strongest in the sensitive region.
spacer

• View the DATABASE results for 'Sensitive Volume' (3).Open this link in a new window

Searchterm 'Homogeneity' was also found in the following services: 
spacer
News  (1)  Forum  (5)  
 
Shady ArtifactInfoSheet: - Artifacts - 
Case Studies, 
Reduction Index, 
etc.MRI Resource Directory:
 - Artifacts -
 
Quick Overview
Artifact Information
NAME
Shady artifact
DESCRIPTION
Localized inhomogeneous brightness
REASON
Various causes
HELP
Check the correct positioning, call the service
Uneven intensity or brightness may occasionally be noted on high field MRI e.g. of the brain. There are various causes of localized inhomogeneous brightness across the MRI images such as improper tuning of the RF transceiver, unbalanced deposition of the RF energy due to incorrect geometry and localized attenuation due to positioning or anatomical variants.
mri safety guidance
Image Guidance
Tuning of the RF transceiver, a homogeneity correction filter and better positioning of the scanned object and/or coil in the scanner.
spacer
Searchterm 'Homogeneity' was also found in the following services: 
spacer
Radiology  (2) Open this link in a new windowUltrasound  (1) Open this link in a new window
ShimmingForum -
related threads
 
Correction of inhomogeneity of the magnetic field produced by the main magnet of a MRI system due to imperfections in the magnet or to the presence of external ferromagnetic objects. May involve changing the configuration of the magnet or the using of shim coils (active shimming) or adding or removing steel from the magnets poles (passive shimming) to fine-tune the magnetic field.

See also the related poll result: 'Most outages of your scanning system are caused by failure of'
spacer

• View the DATABASE results for 'Shimming' (71).Open this link in a new window

 
Further Reading:
  News & More:
Implementation of Dual-Source RF Excitation in 3 T MR-Scanners Allows for Nearly Identical ADC Values Compared to 1.5 T MR Scanners in the Abdomen
Wednesday, 29 February 2012   by www.plosone.org    
MRI Resources 
Developers - Stimulator pool - Online Books - MRI Centers - Image Quality - MRCP
 
previous      36 - 40 (of 48)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]