Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Intravascular Contrast Agents' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Intravascular Contrast Agents' found in 1 term [] and 7 definitions [], (+ 12 Boolean[] results
previous     16 - 20 (of 20)     
Result Pages : [1]  [2]  [3 4]
Searchterm 'Intravascular Contrast Agents' was also found in the following services: 
spacer
News  (1)  Resources  (1)  
 
OptiMARK®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
OptiMARK® is a formulation of a nonionic gadolinium chelate of diethylenetriamine pentaacetic acid bismethoxyethylamide (gadoversetamide), for use as a paramagnetic MRI contrast agent. OptiMARK® (gadoversetamide injection) is to be administered by intravenous injection. OptiMARK® is indicated for MRI diagnostic procedures to provide increased enhancement and visualization of lesions of the brain, spine and liver, including tumors.

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.
Drug Information and Specification
NAME OF COMPOUND
Gadoversetamide, Gd-DTPA-BMEA
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
Paramagnetic
PHARMACOKINETIC
Intravascular, extracellular
1110 mosm/kgH2O
CONCENTRATION
0.5 mol/L
DOSAGE
0.1 mmol/kg / 0.2 mL/kg
PREPARATION
Finished product
INDICATION
Neuro/whole body
DEVELOPMENT STAGE
For sale / Phase III
DISTRIBUTOR
See below
PRESENTATION
Vials of 5, 10, 15, 20, 50 mL and Pre-filled syringes of 10, 15, 20 and 30 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
OptiMARK®
for sale
Australia
OptiMARK®
for sale
spacer
 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
OptiMARK® , package insert
MATERIAL SAFETY DATA SHEET
OptiMARK® (gadoversetamide injection)
  News & More:
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
Spurious Hypocalcemia After Omniscan- or OptiMARK-Enhanced Magnetic Resonance Imaging: An Algorithm for Minimizing a False-Positive Laboratory Value
October 2004   by www.findarticles.com    
FDA Drug Safety Communication: FDA warns that gadolinium-based contrast agents (GBCAs) are retained in the body; requires new class warnings
Tuesday, 19 December 2017   by www.fda.gov    
MRI Resources 
Spine MRI - Movies - Software - Calculation - Crystallography - Bioinformatics
 
ProHance®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
ProHance® consists of a nonionic gadolinium complex (Gadoteridol) used as a paramagnetic MR contrast agent.
ProHance® provides contrast enhancement of the brain, spine and surrounding tissues resulting in improved visualization (compared with unenhanced MRI) of lesions with abnormal vascularity or those thought to cause a disruption of the normal blood brain barrier. ProHance® can also be used for whole body contrast enhanced MRI including the head, neck, liver, breast, musculoskeletal system and soft tissue pathologies.

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.

See Gadoteridol.
Drug Information and Specification
NAME OF COMPOUND
Gadoteridol, Gd-HP-DO3A
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
r1=3.7, r2=4.8, B0=1.0T
PHARMACOKINETIC
Intravascular, extracellular, renal excretion
630 mosm/kgH2O
CONCENTRATION
0.5 mol/L, 279.3mg/ml
DOSAGE
0.1 mmol Gd/kg
PREPARATION
Finished product
INDICATION
Neuro/whole body
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Vials of 5, 10, 15 and 20 mL
Glass syringes of 5, 10, 15 and 17 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
EU
ProHance®
for sale
Australia
ProHance®
for sale
Japan
ProHance®
for sale
spacer

• View the DATABASE results for 'ProHance®' (6).Open this link in a new window

 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
Prohance Product Information
   by www.drugs.com    
  News & More:
RSNA Statement on Gadolinium-Based MR Contrast Agents
Thursday, 1 February 2018   by www.rsna.org    
Spurious Hypocalcemia After Omniscan- or OptiMARK-Enhanced Magnetic Resonance Imaging: An Algorithm for Minimizing a False-Positive Laboratory Value
October 2004   by www.findarticles.com    
FDA Drug Safety Communication: FDA warns that gadolinium-based contrast agents (GBCAs) are retained in the body; requires new class warnings
Tuesday, 19 December 2017   by www.fda.gov    
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
MRI Resources 
Functional MRI - Nerve Stimulator - Coils - Absorption and Emission - MRCP - Jobs
 
Superparamagnetic Contrast AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Small particles of ferrite are used as superparamagnetic contrast medium in MR imaging (appearing predominantly dark on MRI). These agents exhibit strong T1 relaxation properties, and due to susceptibility differences to their surroundings also produce a strongly varying local magnetic field, which enhances T2 relaxation to darken the contrast media containing structures.
Superparamagnetic contrast agents are also known by the abbreviation SPIO's (small particle iron oxide or superparamagnetic iron oxide) and USPIO's (ultrasmall particle iron oxide or ultrasmall superparamagnetic iron oxide).
Two types of USPIO will be available on the market as blood pool agents, while SPIO's have been used as darkening contrast agents for liver imaging. As particulate matter they are taken up by the RES. Very small particles of less than 300 nanometers also remain intravascular for a prolonged period of time and thus can serve as blood pool agents.

See also the related poll result: 'The development of contrast agents in MRI is'
spacer

• View the DATABASE results for 'Superparamagnetic Contrast Agents' (12).Open this link in a new window

 
Further Reading:
  News & More:
Optimized Labelling of Human Monocytes with Iron Oxide MR Contrast Agents
Sunday, 30 November 2003   by rsna2003.rsna.org    
Poly (dopamine) coated superparamagnetic iron oxide nanocluster for noninvasive labeling, tracking, and targeted delivery of adipose tissue-derived stem cells
Tuesday, 5 January 2016   by www.nature.com    
Searchterm 'Intravascular Contrast Agents' was also found in the following services: 
spacer
News  (1)  Resources  (1)  
 
DyamideInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Some dyamides are under preclinical development as intravascular MRI contrast agents for blood flow perfusion.

Short name: Dy-DTPA-BMA, generic name: Sprodyamide, central moiety: Dy2+, contrast effect: T2*enhanced, relaxivity: r1=3.4, r2=3.8, B0=0.47,

Short name: Dy-DTPA, central moiety: Dy2+, contrast effect: T2*enhanced,

Short name: Albumin-(Dy-DTPA)x, central moiety: Dy2+, contrast effect: T2*enhanced.
spacer
 
Further Reading:
  Basics:
Dysprosium
   by www.scescape.net    
MRI Resources 
Colonography - Safety pool - Contrast Enhanced MRI - Education - Directories - Artifacts
 
Extracellular Fluid AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
The contrast agents are either renal or hepatically excreted media, which stay in the intravascular/extracellular tissue compartment. The enhancement in the blood continues for as long as the contrast agent remains in the blood stream.
E.g. Dotarem®, Magnevist®, Omniscan®, ProHance®.

See Contrast Medium, Contrast Agents and Blood Pool Agents.
spacer

• View the DATABASE results for 'Extracellular Fluid Agents' (2).Open this link in a new window

MRI Resources 
Non-English - Image Quality - Devices - Fluorescence - Implant and Prosthesis - Claustrophobia
 
previous      16 - 20 (of 20)     
Result Pages : [1]  [2]  [3 4]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 3 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]