Helium
 
The element helium (He) was discovered 1868 when P.J.C. Janssen and N. Lockyer detected a new line in the solar spectrum during the solar eclipse. Lockyer and E. Frankland suggested the name helium (Gr. Helios, the sun) for the new element. In 1895, helium was discovered in the uranium mineral cleveite and in 1907 it was found out that alpha particles are helium nuclei.
Properties: Helium belongs to the noble gases, is colorless, odorless, and occurs in two naturally isotopes, helium 3 and helium 4. As an inert gas, helium does not react chemically largely and don't burns. Helium 4 makes up over 99% of naturally occurring helium atoms. Helium is extracted from natural gas e.g. present in various radioactive minerals as a decay product. Deposits and sources are in the USA, Poland, the USSR, and a few in India. The rare deposits and increased consumption lead to a shortage of this gas.
K. Onnes worked for many years to liquefy helium, which persisted as a gas to the lowest temperature. Helium does not freeze at atmospheric pressure. The density of helium vapor at his boiling point of 4.2 Kelvin is very high, with the vapor expanding greatly when heated to room temperature. Nb, Tc, Pb, La, V, and Ta are superconductors at liquid helium temperature. Liquid helium is commonly used as a cryogen for superconducting magnets. A rapid evaporation of the cryogen is named Quench. See also Quenching.
mri safety guidance
MRI Safety Guidance
Cryogenic liquids and their associated cold vapors can produce effects on the skin similar to a thermal burn and can cause frostbite. Prolonged breathing of extremely cold gases may damage the lungs and in absence of enough air or oxygen, asphyxiation and death can occur. Unprotected skin can stick to very cold metal (e.g. cooled by liquid helium) and then tear when pulled away.
spacer
 
• Related Searches:
    • MRI Safety
    • Device
    • Element
    • Cryostat
    • Quench
 
Further Reading:
  Basics:
Superfluid helium-4
Monday, 12 February 2018   by en.wikipedia.org    
Cryogenic Liquids and their Hazards
   by www.ccohs.ca    
Liquid Helium
   by hyperphysics.phy-astr.gsu.edu    
  News & More:
Renergen surges after xceptionalâ„¢ helium concentration reports
Monday, 29 March 2021   by www.businesslive.co.za    
Not just balloons: Helium shortage may deflate MRIs, airbags and research
Friday, 3 May 2019   by eu.usatoday.com    
Liquid helium, the lifeblood of MRI machines
Tuesday, 5 March 2019   by www.gasworld.com    
Preclinical Imaging Systems Reduce Environmental Impact
Monday, 4 November 2019   by www.itnonline.com    
Huge newfound deposit of helium will keep MRI scanners running
Monday, 27 June 2016   by www.newscientist.com    
Philips launches Ingenia Ambition X 1.5T MR with industry-first fully sealed magnet for more productive, helium-free operations
Tuesday, 11 September 2018   by www.philips.com    
Tech firms, medical research threatened by helium shortage
Thursday, 19 September 2013   by www.livemint.com    
How 9/11 Made The Global Helium Shortage Worse
Thursday, 3 July 2014   by www.popsci.com    
Cooling MRI magnets without a continuous supply of scarce helium
Tuesday, 13 August 2013   by www.wired.co.uk    
MRI Resources 
Liver Imaging - Used and Refurbished MRI Equipment - Absorption and Emission - RIS - Chemistry - Examinations
 
Navigator Technique
 
The navigator technique measures with an additional quick MR prepulse the position, of e.g. the diaphragm before data collecting. Similar respiratory conditions of the patient can be identified and used to synchronize image data acquisition so that respiration induced image blurring is minimized by either respiratory ordered phase encoding or respiratory gating.
The prepulse sequence images a small area perpendicular to the structure, which is moving. The contrast of the interface between the diaphragm and the lung should be high to permit easy automatic detection. After data acquisition, the position of the interface is automatically recorded and imaging data are only accepted when the position of the interface falls within a range of prespecified values.
This technique has the advantage of greater accuracy than other respiratory gating (therefore used for coronary angiography) and has no need for additional sensing MRI equipment, as the MR system itself provides it.
spacer

• View the DATABASE results for 'Navigator Technique' (5).Open this link in a new window

MRI Resources 
RIS - Equipment - Spectroscopy - Pediatric and Fetal MRI - Claustrophobia - Databases
 
previous      11 - 12 (of 12)     
Result Pages : [1]  [2 3]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]