Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Lung' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Lung' found in 1 term [] and 11 definitions []
1 - 5 (of 12)     next
Result Pages : [1]  [2 3]
Searchterm 'Lung' was also found in the following services: 
spacer
News  (39)  Resources  (10)  Forum  (4)  
 
Lung ImagingMRI Resource Directory:
 - Lung Imaging -
 
Lung imaging is furthermore a challenge in MRI because of the predominance of air within the lungs and associated susceptibility issues as well as low signal to noise of the inflated lung parenchyma. Cardiac and respiratory triggered or breath hold sequences allow diagnostic imaging, however a comparable image quality with computed tomography is still difficult to achieve.
Assumptions for lung MRI:
Low signal to noise ratio of the inherently low lung proton density.
Cardiac and respiratory motion artifacts.
Magnetic susceptibility effects of large magnetic field gradients.
Very short transverse relaxation times and significant diffusion yielding short T2 (30-70 msec), short T2* (1-3 msec), and additional long T1 relaxation times (1300-1500 msec).
The extreme short T2 values are responsible for a fast signal decay during a single shot readout, resulting in blurring.

The current trends in MRI are the use of new imaging technologies and increasingly powerful magnetic fields. Among these technologies are parallel imaging techniques as well as ventilation agents like hyperpolarized helium for the use as an inert inhalational contrast agent to study lung ventilation properties. With hyperpolarized gases clear images of the lungs can be obtained without using a large magnetic field (see also back projection imaging). Single shot sequences (e.g. TSE or Half Fourier Acquisition Single Shot Turbo Spin Echo HASTE) used in lung MR imaging benefits from parallel imaging techniques due to reduced relaxation time effects during the echo train and therefore reduced image blurring as well as reduced motion artifacts.
In the future, more effective contrast agents may provide an alternative solution to the need for high field MRI. Dynamic contrast enhanced MRI perfusion has demonstrated a potential in the diagnosis of pulmonary embolism or to characterize lung cancer and mediastinal tumors. 3D contrast enhanced magnetic resonance angiography of the thoracic vessel.

See also the related poll result: 'MRI will have replaced 50% of x-ray exams by'
 
Images, Movies, Sliders:
 Anatomic Imaging of the Lungs  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 Normal Lung Gd Perfusion MRI  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 MRI Thorax Basal Plane  Open this link in a new window
 
Radiology-tip.comradLung Scintigraphy
spacer
 
• Share the entry 'Lung Imaging':  Facebook  Twitter  LinkedIn  
 
• Related Searches:
    • Abdominal Imaging
    • Contrast Enhanced MRI
    • Cardiac MRI
    • Respiratory Trigger
    • Breath Hold Imaging
 
Further Reading:
  Basics:
A safer approach for diagnostic medical imaging
Monday, 29 September 2014   by www.eurekalert.org    
Parallel Lung Imaging(.pdf)
  News & More:
Chest MRI a viable alternative to chest CT in COVID-19 pneumonia follow-up
Monday, 21 September 2020   by www.healthimaging.com    
CT Imaging Features of 2019 Novel Corona virus (2019-nCoV)
Tuesday, 4 February 2020   by pubs.rsna.org    
Polarean Imaging Phase III Trial Results Point to Potential Improvements in Lung Imaging
Wednesday, 29 January 2020   by www.diagnosticimaging.com    
Low Power MRI Helps Image Lungs, Brings Costs Down
Thursday, 10 October 2019   by www.medgadget.com    
Chest MRI Using Multivane-XD, a Novel T2-Weighted Free Breathing MR Sequence
Thursday, 11 July 2019   by www.sciencedirect.co    
Researchers Review Importance of Non-Invasive Imaging in Diagnosis and Management of PAH
Wednesday, 11 March 2015   by lungdiseasenews.com    
New MRI Approach Reveals Bronchiectasis' Key Features Within the Lung
Thursday, 13 November 2014   by lungdiseasenews.com    
MRI techniques improve pulmonary embolism detection
Monday, 19 March 2012   by medicalxpress.com    
  News & More:
Partnership with VIDA to streamline adoption of advanced MRI of the lungs
Monday, 11 September 2023   by www.itnonline.com    
MRI Resources 
Cochlear Implant - Absorption and Emission - Resources - Liver Imaging - Most Wanted - Functional MRI
 
Ventilation AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Inert hyperpolarized gases are under development for imaging air spaces, including those in the lungs. Because they mostly contain air and water, lungs are difficult organs to image.
These ventilation agents (gases) have potential in lung imaging and are currently used in studies of the pulmonary ventilation:
perfluorinated gases
aerosolized gadolinium-DTPA
hyperpolarized gases (xenon-129, helium-3)
molecular oxygen

Specific isotopes of inert gases can be hyperpolarized. Hyperpolarized is a state in which almost all of the atoms nuclei are spinning in the same direction. Once the nuclei in the isotope 3He have been hyperpolarized using a laser, they remain in this state for several days. The inert, hyperpolarized gas can then be used in a lung imaging study, where the high concentration of polarized nuclei provides a sharp contrast in MRI. The technique is already being developed with a view to commercialization by Magnetic Imaging Technologies in Durham, North Carolina. According to the company, existing MRI equipment can be used with a few minor modifications, along with a gas polarizer. The technique could provide early detection and monitoring of pulmonary disease.
Hyperpolarized 129Xe can also be used as a magnetic resonance tracer because of its MR-enhanced sensitivity combined with its high solubility. This isotope differs from 3He in that it can dissolve in the blood. Strong enhancement of the nuclear spin polarization of xenon in the gas phase can be achieved by optical pumping of rubidium and subsequent spin-exchange with the xenon nuclei. This technique can increase the magnetic resonance signal of xenon by five orders of magnitude, thus allowing NMR detection of xenon in very low concentration. MR spectroscopy and imaging of optically polarized xenon shows considerable potential for medical applications (see also back projection imaging).
Nycomed Amersham anticipated the market for inert gases in pulmonary imaging. The company obtained an exclusive license for the use of helium (He) and xenon (Xe) as MRI contrast agents. Currently, the US FDA has not yet approved the commercial distribution of inert gas imaging equipment, because the technique is still undergoing trials.
spacer

• View the DATABASE results for 'Ventilation Agents' (3).Open this link in a new window

 
Further Reading:
  Basics:
New oxygen-enhanced MRI scan 'helps identify most dangerous tumours'
Thursday, 10 December 2015   by www.dailymail.co.uk    
Low-Field MRI of Laser Polarized Noble Gas
   by xenon.unh.edu    
  News & More:
Hyperpolarized Gas MRI for Pulmonary Disease Assessment: Interview with Richard Hullihen, CEO of Polarean Imaging
Wednesday, 9 September 2020   by www.medgadget.com    
Pumpkin-shaped molecule enables 100-fold improved MRI contrast: new agent for detecting pathological cells
Tuesday, 13 October 2015   by phys.org    
MRI Mapping of Cerebrovascular Reactivity via Gas Inhalation Challenges
Wednesday, 17 December 2014   by www.jove.com    
Using MRI to study gas reactions
Thursday, 31 January 2008   by www.theengineer.co.uk    
New Technique Reveals Insights Into Lung Disease
Thursday, 13 December 2007   by www.sciencedaily.com    
MRI Resources 
MRA - Mobile MRI - Patient Information - Collections - Developers - Implant and Prosthesis
 
Upperton LimitedMRI Resource Directory:
 - Developers -
 
www.upperton.com/products.htm Research Project Description
Lung Imaging X-ray and MRI contrast agents for lung MRI applications.
Blood Pool Imaging MRI contrast agents for vascular and targeted imaging.

Nuclear Imaging Agents based on recombinant human albumin for nuclear imaging.
Contact Information
MAIL
Upperton Limited
Dr Richard Johnson
PO Box 6861
Nottingham, NG2 5PF
Great Britain
PHONE
+44-(0)115-945-2378
FAX
+44-(0)115-945-2378
spacer
 
Further Reading:
  Basics:
Blood-Pool Imaging Using Technetium-99m-Labeled Liposomes(.pdf)
   by jnm.snmjournals.org    
Searchterm 'Lung' was also found in the following services: 
spacer
News  (39)  Resources  (10)  Forum  (4)  
 
Back Projection Imaging
 
This imaging technique is probably the earliest, but rarely used today. Most of today's imaging techniques are based on the Fourier transform, and fill the Cartesian grid of points in k-space line by line by a sequence of applied gradients. Back projection imaging performs a radial filling of the k-space by a one dimensional field gradient, applied at different angles. Back projection imaging is still in use in laser polarized noble gas imaging (see ventilation agents and lung imaging).
spacer

• View the DATABASE results for 'Back Projection Imaging' (3).Open this link in a new window

 
Further Reading:
  Basics:
Primer on Magentic Resonance Imaging Tomography
   by research.physics.lsa.umich.edu    
The Basics of MRI
   by www.cis.rit.edu    
MRI Resources 
Pathology - Guidance - Diffusion Weighted Imaging - Used and Refurbished MRI Equipment - MR Guided Interventions - Hospitals
 
Computer Aided Detection
 
(CAD) 'Computer aided detection' or 'computer assisted diagnosis' systems are tools to improve the efficiency and workflow in medical imaging procedures. The aim of CAD is to increase the diagnostic accuracy of screening procedures by using a computer system to locate abnormalities, improve image management, correct patient movement and assist the radiologists in the interpretation and analysis of data-intensive studies. Typical applications include the tumor detection in mammography, breast MRI, colonography, and lung imaging. Newer applications like prostate MRI are under investigation.

See also MR Guided Interventions, Breast MRI and Hybrid Imaging.
spacer

• View the DATABASE results for 'Computer Aided Detection' (3).Open this link in a new window


• View the NEWS results for 'Computer Aided Detection' (7).Open this link in a new window.
 
Further Reading:
  News & More:
Evaluating brain MRI scans with the help of artificial intelligence
Thursday, 2 June 2022   by www.technologyreview.com    
New AI Tool for Prostate MRI Analysis to Support PI-RADS Scoring
Monday, 11 April 2022   by www.itnonline.com    
Superhuman 20 second AI heart tool begins NHS roll-out
Friday, 11 March 2022   by www.bhf.org.uk    
Computer-aided detection and diagnosis for prostate cancer based on mono and multi-parametric MRI: A review - Abstract
Tuesday, 28 April 2015   by urotoday.com    
MRI method for measuring MS progression validated
Thursday, 19 December 2013   by www.eurekalert.org    
MRI Resources 
Knee MRI - MRI Technician and Technologist Schools - MRI Technician and Technologist Jobs - Movies - Quality Advice - Supplies
 
     1 - 5 (of 12)     next
Result Pages : [1]  [2 3]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising