| Info Sheets |
| | | | | | | | | | | | | | | | | | | | | | | | |
| Out- side |
| | | | |
|
| | | | |
Result : Searchterm 'MAGNETOM C' found in 2 terms [] and 1 definition [], (+ 15 Boolean[] results
| previous 11 - 15 (of 18) nextResult Pages : [1] [2 3 4] | | | | Searchterm 'MAGNETOM C' was also found in the following services: | | | | |
| | |
| |
|
From Siemens Medical Systems;
Re ceived FDA clearan ce in 2007.
The MAGNETOM Verio provides up to 102 integrated matrix coil elements and up to 32 independent radiofrequen cy channels that allow flexible coil combinations to make patient and coil repositioning virtually unne cessary. The Tim (total imaging matrix) te chnology also in creases patient throughput due to a shorter scan time.
The open bore design offers great comfort for patients of all shapes and sizes.
Device Information and Spe cifi cation
CLINICAL APPLICATION
Whole Body
CONFIGURATION
Ultra-short open bore
Head, spine, torso/ body coil, neurovas cular, cardiac, ne ck and multi-purpose flex coils. Peripheral vas cular, breast, shoulder, knee, wrist, foot//ankle, TMJ optional.
CHANNELS (min. / max. configuration)
8, 18, 32
Chemi cal shift imaging, single voxel spe ctros copy
MAGNET WEIGHT (gantry in cluded)
8200 kg
DIMENSION H*W*D (gantry included)
173 x 230 x 222 cm
Passive, active; first order,
second order standard
POWER REQUIREMENTS
380 / 400 / 420 / 440 / 460 / 480 V, 3-phase + ground; 110 kVA
| | | | | |
| | | | | |
| |
|
From Siemens Medical Systems;
Re ceived FDA clearan ce in 2010.
MAGNETOM Skyra is a top-of-the-line, patient friendly wide bore 3 Tesla MRI system.
The system is equipped with the Tim 4G and Dot system (Total imaging matrix and Day optimizing throughput), to enhan ce both produ ctivity and image quality with the complete range of advan ced appli cations for clini cal routine and resear ch. Tim 4G features lighter, trimmer MRI coils that take up less spa ce inside the magnet but deliver a high coil element density with in creased signal to noise ratio and the possibility to use high iPAT fa ctors.
Device Information and Spe cifi cation
CLINICAL APPLICATION
Whole Body
Head, spine, torso/ body coil, neurovas cular, cardiac, ne ck, shoulder, knee, wrist, foot//ankle and multi-purpose flex coils. Peripheral vas cular, breast, shoulder.
CHANNELS (min. / max. configuration)
48, 64, 128
Chemi cal shift imaging, single voxel spe ctros copy
MINIMUM TE
3D T1 spoiled GRE: 0.22 (256 matrix), Ultra-short TE
At isocenter: L-R 70 cm, A-P (with table) 55 cm
MAGNET WEIGHT (gantry in cluded)
5768 kg
DIMENSION H*W*D (gantry included)
173 x 231 x 219 cm
COOLING SYSTEM
Water; single cryogen, 2 stage refrigeration
3 linear with 20 coils, 5 nonlinear 2nd-order
POWER REQUIREMENTS
380 / 400 / 420 / 440 / 460 / 480 V, 3-phase + ground; 110 kVA
| | | | | |
| | | | | |
| |
|
From Siemens Medical Systems;
the 3 T MAGNETOM Allegra is a dedi cated MR heads canner, perfe ct as a resear ch system in cognitive and neuros cien ce with MRS and fMRI. MAGNETOM Allegra is a full member of the MAGNETOM produ ct family. It uses many common components, i.e. ele ctroni cs, computer system, software and pulse sequence con cepts.
Device Information and Spe cifi cation
GRE, IR, FIR, STIR, TrueIR/FISP, FSE, FLAIR, MT, SS-FSE, MT-SE, MTC, MSE, EPI, GMR, fat/water sat./ex c.
IMAGING MODES
Single, multisli ce, volume study, multi angle, multi oblique
178 images/se c at 256 x 256 at 100% FOV
1024 x 1024 full screen display
MAGNET WEIGHT (gantry in cluded)
5500 kg
DIMENSION H*W*D (gantry included)
220 x 220 x 147 cm
POWER REQUIREMENTS
380/400/420/440/480 V
Passive, act.; 1st order std./2nd opt.
| | | | • View the DATABASE results for 'MAGNETOM Allegra™' (2).
| | | | |
| | | Searchterm 'MAGNETOM C' was also found in the following services: | | | | |
| | |
| |
|
Device Information and Spe cifi cation
CLINICAL APPLICATION
Whole body
GRE, IR, FIR, STIR, TrueIR/FISP, FSE, FLAIR, MT, SS-FSE, MT-SE, MTC, MSE, EPI, GMR, fat/water sat./ex c.
IMAGING MODES
Single, multisli ce, volume study, multi angle, multi oblique
TR
2.4 msec std.; 2.0 opt.; 1.8 w/ 30mT/m at 256matrix
TE
1.1 msec std.; 0.9 opt.; 0.78 w/30 mT/m at 256matrix
178 images/se c at 256 x 256 at 100% FOV
1024 x 1024 full screen display
21 micrometer in plane, 11 micrometer optional
MAGNET WEIGHT (gantry in cluded)
3500kg, 5000kg in operation
DIMENSION H*W*D (gantry included)
POWER REQUIREMENTS
380/400/420/440/480 V
STRENGTH
20/35 mT/m standard, 30/52 opt.
Passive, act.; 1st order std./2nd opt.
| | | | • View the DATABASE results for 'MAGNETOM Harmony™' (2).
| | | | Further Reading: | Basics:
|
|
| |
| | | | | |
| |
|
From Siemens Medical Systems;
the MAGNETOM Rhapsody™. This open MRI system offers the proven image
quality of 1.0 Tesla. In addition to the resulting broad range of appli cations, the open magnet of the high field system MAGNETOM Rhapsodyâ„¢ fa cilitates examination of claustrophobi c and pediatri c patients. And the system allows for expanded interventional appli cations.
Device Information and Spe cifi cation CLINICAL APPLICATION Whole body GRE, IR, FIR, STIR, TrueIR/FISP, FSE, FLAIR, MT, SS-FSE, MT-SE, MTC, MSE, EPI, GMR, fat/water sat./ex c. IMAGING MODES Single, multisli ce, volume study, multi angle, multi oblique1024 x 1024 full screen display POWER REQUIREMENTS 380/400/420/440/480 V | | | | • View the DATABASE results for 'MAGNETOM Rhapsody™' (2).
| | | | |
| | | | |
| |
| | | |
|
| |
| Look Ups |
| |