M
agnetic
R
esonance -
T
echnology
I
nformation
P
ortal
Welcome to MRI Technology
•
Database
Forum
News
Resources
Contact
Info
Sheets
Artifacts
Coils
Contrast Agents
Devices
MRI Safety
Sequences
Images
Sliders
Abbreviations
Acronyms
Protocols
Patient
Information
Out-
side
Congresses
Resources
See a comprehensive list of contrast agents!
From Abdoscan® to Teslascan®.
'Magnetization Transfer Contrast'
SEARCH FOR
search it again
Magnetic Resona...
Magnetization T...
Magnetic Resona...
2
3
5
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
Result : Searchterm
'
Magnetization Transfer Contrast
'
found in
1
term [
] and
4
definitions [
], (+
1
Boolean[
] results
previous
6
(of 6)
Result Pages :
[
1
]
[
2
]
MRI Resources
Hospitals
-
MRI Reimbursement
-
Shoulder MRI
-
MRI Centers
-
Spectroscopy
-
Lung Imaging
Paramagnetic Chemical Exchange Saturation
Transfer
(PARACEST) The alteration of the
proton density
or total water signal changes
contrast
and can be detected by the
MRI
scanner. Paramagnetic chemical exchange
saturation
transfer
contrast
agents
are based upon the
magnetization
transfer
mechanism.
Lanthanide ion complexes formed with tetra-amide based ligands display unusually slow water exchange kinetics and this feature may be used to alter image
contrast
by applying a selective
presaturation
pulse in an
imaging sequence
. This results in chemical exchange
saturation
transfer
(CEST) from the lanthanide-bound water to bulk water thereby altering image
contrast
.
Chemical Exchange
Saturation
Transfer
(CEST) agents are a class of
contrast
agents
that could potentially revolutionize the
MRI
field because of their improved sensitivity and can have a great impact on
functional magnetic resonance imaging
.
Further Reading:
Basics:
Multimodal Nanoparticles for Quantitative Imaging
(.pdf)
Tuesday, 13 December 2011
by
alexandria.tue.nl
News & More:
New Brain Imaging Technique Identifies Previously Undetected Epileptic Seizure Sites
Friday, 13 November 2015
by
www.newswise.com
Non-invasive Imaging Method For Diagnosing Osteoarthritis Developed
Friday, 15 February 2008
by
www.sciencedaily.com
MRI Resources
MRI Reimbursement
-
Developers
-
Implant and Prosthesis pool
-
Pacemaker
-
Bioinformatics
-
Spine MRI
previous
6
(of 6)
Result Pages :
[
1
]
[
2
]
Random Page
top
Share This Page
MR-TIP
Community
User
Pass
Register (free)
Member
Services
MRI is trending to low field magnets
:
reduced costs will lead to this change
AI will close the gap to high field
only in remote areas
is only temporary
never
Contribute
Results
Look
Ups
Greeks
Symbols
Units & M.
Radiology
Ultrasound
MRI
Give MR-TIP a Feedback
Help Page
Submit a
Link/Resource
(login or register first)
MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.
Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP •
Radiology-TIP
•
Medical-Ultrasound-Imaging
•
Copyright © 2003 - 2024
SoftWays
. All rights reserved. [ 31 March 2025]
Terms of Use
|
Privacy Policy
|
Advertising
[last update: 2024-02-26 03:41:00]