Result : Searchterm 'Mass' found in 1 term [] and 23 definitions []
previous     6 - 10 (of 24)     next
Result Pages : [1]  [2 3 4 5]
Searchterm 'Mass' was also found in the following services: 
spacer
News  (43)  Resources  (48)  Forum  (3)  
 
Abdominal ImagingMRI Resource Directory:
 - Abdominal Imaging -
 
General MRI of the abdomen can consist of T1 or T2 weighted spin echo, fast spin echo (FSE, TSE) or gradient echo sequences with fat suppression and contrast enhanced MRI techniques. The examined organs include liver, pancreas, spleen, kidneys, adrenals as well as parts of the stomach and intestine (see also gastrointestinal imaging). Respiratory compensation and breath hold imaging is mandatory for a good image quality.
T1 weighted sequences are more sensitive for lesion detection than T2 weighted sequences at 0.5 T, while higher field strengths (greater than 1.0 T), T2 weighted and spoiled gradient echo sequences are used for focal lesion detection. Gradient echo in phase T1 breath hold can be performed as a dynamic series with the ability to visualize the blood distribution. Phases of contrast enhancement include the capillary or arterial dominant phase for demonstrating hypervascular lesions, in liver imaging the portal venous phase demonstrates the maximum difference between the liver and hypovascular lesions, while the equilibrium phase demonstrates interstitial disbursement for edematous and malignant tissues.
Out of phase gradient echo imaging for the abdomen is a lipid-type tissue sensitive sequence and is useful for the visualization of focal hepatic lesions, fatty liver (see also Dixon), hemochromatosis, adrenal lesions and renal masses. The standards for abdominal MRI vary according to clinical sites based on sequence availability and MRI equipment. Specific abdominal imaging coils and liver-specific contrast agents targeted to the healthy liver tissue improve the detection and localization of lesions.
See also Hepatobiliary Contrast Agents, Reticuloendothelial Contrast Agents, and Oral Contrast Agents.

For Ultrasound Imaging (USI) see Abdominal Ultrasound at Medical-Ultrasound-Imaging.com.
 
Images, Movies, Sliders:
 MR Colonography Gadolinium per Rectum  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 Anatomic Imaging of the Liver  Open this link in a new window
      

 CE MRA of the Aorta  Open this link in a new window
    
SlidersSliders Overview

 
spacer
 
• Related Searches:
    • Positive Oral Contrast Agents
    • Liver Imaging
    • Computer Aided Detection
    • Single Shot Technique
    • Contrast Enhanced MRI
 
Further Reading:
  Basics:
Abbreviated MRI Protocols for the Abdomen
Friday, 22 March 2019   by pubs.rsna.org    
Abdominal MRI at 3.0 T: The Basics Revisited
Wednesday, 20 July 2005   by www.ajronline.org    
Usefulness of MR Imaging for Diseases of the Small Intestine: Comparison with CT
2000   by www.ncbi.nlm.nih.gov    
  News & More:
Assessment of Female Pelvic Pathologies: A Cross-Sectional Study Among Patients Undergoing Magnetic Resonance Imaging for Pelvic Assessment at the Maternity and Children Hospital, Qassim Region, Saudi Arabia
Saturday, 7 October 2023   by www.cureus.com    
Higher Visceral, Subcutaneous Fat Levels Predict Brain Volume Loss in Midlife
Wednesday, 4 October 2023   by www.neurologyadvisor.com    
Deep Learning Helps Provide Accurate Kidney Volume Measurements
Tuesday, 27 September 2022   by www.rsna.org    
CT, MRI for pediatric pancreatitis interobserver agreement with INSPPIRE
Friday, 11 March 2022   by www.eurekalert.org    
Clinical trial: Using MRI for prostate cancer diagnosis equals or beats current standard
Thursday, 4 February 2021   by www.eurekalert.org    
Computer-aided detection and diagnosis for prostate cancer based on mono and multi-parametric MRI: A review - Abstract
Tuesday, 28 April 2015   by urotoday.com    
Nottingham scientists exploit MRI technology to assist in the treatment of IBS
Thursday, 9 January 2014   by www.news-medical.net    
New MR sequence helps radiologists more accurately evaluate abnormalities of the uterus and ovaries
Thursday, 23 April 2009   by www.eurekalert.org    
MRI identifies 'hidden' fat that puts adolescents at risk for disease
Tuesday, 27 February 2007   by www.eurekalert.org    
Searchterm 'Mass' was also found in the following services: 
spacer
Radiology  (29) Open this link in a new windowUltrasound  (15) Open this link in a new window
Absorbed Dose
 
This dose means the RF power absorbed per unit of mass of an object, and is measured in watts per kilogram (W/kg).
The absorbed dose is dependent on the duty cycle and transmitter-coil type and increases with field strength, radio frequency power and and body size.
The specific absorption rate (SAR) describes the potential for heating of the patient's tissue due to the application of the RF energy necessary to produce the MR signal.

See also Specific Absorption Rate, MRI Safety, and MRI Risks.
spacer

• View the DATABASE results for 'Absorbed Dose' (2).Open this link in a new window

 
Further Reading:
  Basics:
Commission delays electromagnetic fields legislation
Monday, 29 October 2007   by cordis.europa.eu:80    
Physics of MRI Safety
   by www.aapm.org    
  News & More:
SED Guidance
Saturday, 1 January 2022   by www.mriphysics.scot.nhs.uk    
Specific Absorption Rate and Specific Energy Dose: Comparison of 1.5-T versus 3.0-T Fetal MRI
Tuesday, 7 April 2020   by pubs.rsna.org    
Evaluation of Absorbed Dose by MRI Read-Out
Saturday, 18 November 2017   by www.jstage.jst.go.jp    
MRI Resources 
Jobs pool - Sequences - Non-English - Diffusion Weighted Imaging - Most Wanted - Manufacturers
 
Aurora Imaging Technology, Inc.
 
www.auroramri.com Aurora Imaging Technology, Inc., a private company, is located in North Andover, Massachusetts. As a leading innovator in the breast imaging industry, the company provides with its Aurora System the detection, diagnosis, biopsy and treatment of breast cancer. Aurora Imaging Technology Inc. develops and manufactures the Aurora® 1.5T Dedicated Breast MR System, the first and only FDA approved MRI system designed specifically for breast imaging.

MRI Scanners:
Contact Information
MAIL
Aurora Imaging Technology Inc
39 High Street
North Andover, MA 01845
USA
PHONE
+1-877-975-7530
spacer

• View the DATABASE results for 'Aurora Imaging Technology, Inc.' (2).Open this link in a new window


• View the NEWS results for 'Aurora Imaging Technology, Inc.' (5).Open this link in a new window.
 
Further Reading:
  News & More:
Global Magnetic Resonance Imaging Systems Market Data Analysis 2019-2025 Aurora Imaging Technology, Esaote, Fonar Corporation
Wednesday, 8 January 2020   by citiblognews.com    
Searchterm 'Mass' was also found in the following services: 
spacer
News  (43)  Resources  (48)  Forum  (3)  
 
Bruker BioSpin AGMRI Resource Directory:
 - Manufacturers -
 
www.fonar.com/standup.htm Swiss-based, formerly Bruker AG - split on the 5th October 2001 into the groups: Bruker Daltonics (Mass spectroscopy), Bruker Optics (Infrared spectroscopy), Bruker AXS (X-ray spectroscopy) and Bruker BioSpin (The largest part, the NMR business core, the EPR and the Tomography activities).
Product Lines:
BioSpec® - All-round MR imaging and spectroscopy for research laboratories. Product Specification
BioSpec® Vertical - The vertical BioSpec®, designed for MRI and fMRI applications in primates. Product Specification
MedSpec® - High-field MRI and MRS for human applications at 4 T and above. Product Specification
PharmaScan® - MRI//MRS systems tailored to high-throughput and routine applications in pharmaceutical research. Product Specification
Contact Information
Please see Bruker BioSpin AG's
spacer

• View the NEWS results for 'Bruker BioSpin AG' (1).Open this link in a new window.
 
Further Reading:
  News & More:
BOLD MRI measures connectivity deficits related to MS
July 2002
Searchterm 'Mass' was also found in the following services: 
spacer
Radiology  (29) Open this link in a new windowUltrasound  (15) Open this link in a new window
Cardiac MRIForum -
related threads
 
In the last years, cardiac MRI techniques have progressively improved. No other noninvasive imaging modality provides the same degree of contrast and temporal resolution for the assessment of cardiovascular anatomy and pathology. Contraindications MRI are the same as for other magnetic resonance techniques.
The primary advantage of MRI is extremely high contrast resolution between different tissue types, including blood. Moreover, MRI is a true 3 dimensional imaging modality and images can be obtained in any oblique plane along the true cardiac axes while preserving high temporal and spatial resolution with precise demonstration of cardiac anatomy without the administration of contrast media.
Due to these properties, MRI can precisely characterize cardiac function and quantify cavity volumes, ejection fraction, and left ventricular mass. In addition, cardiac MRI has the ability to quantify flow (see flow quantification), including bulk flow in vessels, pressure gradients across stenosis, regurgitant fractions and shunt fractions. Valve morphology and area can be determined and the severity of stenosis quantified. In certain disease states, such as myocardial infarction, the contrast resolution of MRI is further improved by the addition of extrinsic contrast agents (see myocardial late enhancement).
A dedicated cardiac coil, and a field strength higher than 1 Tesla is recommended to have sufficient signal. Cardiac MRI acquires ECG gating. Cardiac gating (ECGs) obtained within the MRI scanner, can be degraded by the superimposed electrical potential of flowing blood in the magnetic field. Therefore, excellent contact between the skin and ECG leads is necessary. For male patients, the skin at the lead sites can be shaved. A good cooperation of the patient is necessary because breath holding at the end of expiration is practiced during the most sequences.

See also Displacement Encoding with Stimulated Echoes.
For Ultrasound Imaging (USI) see Cardiac Ultrasound at Medical-Ultrasound-Imaging.com.

See also the related poll results: 'In 2010 your scanner will probably work with a field strength of' and 'MRI will have replaced 50% of x-ray exams by'
 
Images, Movies, Sliders:
 Infarct 4 Chamber Cine  Open this link in a new window
    

Courtesy of  Robert R. Edelman
 MVP Parasternal  Open this link in a new window
    

Courtesy of  Robert R. Edelman
 Delayed Myocardial Contrast Enhancement from Infarct  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 
spacer

• View the DATABASE results for 'Cardiac MRI' (15).Open this link in a new window


• View the NEWS results for 'Cardiac MRI' (15).Open this link in a new window.
 
Further Reading:
  Basics:
Cardiac MRI - Technical Aspects Primer
Wednesday, 7 August 2002
Prediction of Myocardial Viability by MRI
1999   by circ.ahajournals.org    
  News & More:
MRI technology visualizes heart metabolism in real time
Friday, 18 November 2022   by medicalxpress.com    
Even early forms of liver disease affect heart health, Cedars-Sinai study finds
Thursday, 8 December 2022   by www.eurekalert.org    
MRI sheds light on COVID vaccine-associated heart muscle injury
Tuesday, 15 February 2022   by www.sciencedaily.com    
Radiologists must master cardiac CT, MRI to keep pace with demand: The heart is not a magical organ
Monday, 1 March 2021   by www.radiologybusiness.com    
Diffusion weighted imaging (DWI) and diffusion tensor imaging (DTI) in the heart (myocardium)
Sunday, 30 August 2020   by github.com    
Non-invasive diagnostic procedures for suspected CHD: Search reveals informative evidence
Wednesday, 8 July 2020   by medicalxpress.co    
Cardiac MRI Becoming More Widely Available Thanks to AI and Reduced Exam Times
Wednesday, 19 February 2020   by www.dicardiology.com    
Controlling patient's breathing makes cardiac MRI more accurate
Friday, 13 May 2016   by www.upi.com    
Precise visualization of myocardial injury: World's first patient-based cardiac MRI study using 7T MRI
Wednesday, 10 February 2016   by medicalxpress.com    
New technique could allow for safer, more accurate heart scans
Thursday, 10 December 2015   by www.gizmag.com    
MRI Resources 
Pacemaker - Distributors - Education pool - Chemistry - Equipment - IR
 
previous      6 - 10 (of 24)     next
Result Pages : [1]  [2 3 4 5]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]