MetalloporphyrinsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Porphyrins occur naturally in plants and animals. All porphyrin molecules feature an aromatic macrocycle ring with a central binding site. This site accommodates transition metals, which are held in place by inward-facing nitrogen atoms. Metalloporphyrins have usually a low toxicity and a potential of a selective uptake in tumors or necrosis. These properties are advantageous for a use as MRI tumor specific agents with positive enhancement. These contrast agents enhance tumors on T1 weighted sequences, which are isointense to surrounding tissues. Porphyrin-based compounds have also necrosis avid properties; they can depict the extent of myocardial infarction as defined by histopathology.
Metalloporphyrins are also used in photodynamic therapy of tumors. The compounds contain a 'lone star' metal atom at the center of the ring and are 'bigger than the average porphyrin'. They contain five N atoms in the central chelating core and this allows them to form complexes with large trivalent lanthanide metals, which have useful cancer therapy properties.

See also Classifications, Characteristics, etc., Gadophrin, MnIIITPPS4, Necrosis Avid Contrast Agent.
spacer
 
Further Reading:
  Basics:
Relaxometric Investigation of Functional Group Placement on MnTPP Derivatives Supports the Role of the Molecular Electrostatic Potential Maps as a Tool to Design New Metalloporphyrins with Larger Relaxivities(.pdf)
   by www.mdpi.org    
Noninvasive Measurements of Infarct Size After Thrombolysis With a Necrosis-Avid MRI Contrast Agent
1999   by circ.ahajournals.org    
Searchterm 'Mole' was also found in the following services: 
spacer
Radiology  (17) Open this link in a new windowUltrasound  (18) Open this link in a new window
MultiHance®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
MultiHance® is a paramagnetic contrast agent for use in diagnostic magnetic resonance imaging (MRI) of the liver and central nervous system. MultiHance® is a small molecular weight chelate, which tightly binds the Gd atom. The substance is excreted partly by the kidneys, partly by the biliary system, which is especially unique.
MultiHance® is indicated, for the detection of focal liver lesions in patients with known or suspected primary liver cancer (e.g. hepatocellular carcinoma) or metastatic disease.
MultiHance® is also indicated in brain MRI and spine MRI where it improves the detection of lesions and provides diagnostic information additional to that obtained with unenhanced MRI.
Gd-BOPTA-enhanced MRA can provide superior vascular signal intensity and SNR, as compared with Gd-DTPA, due to its higher relaxivity, even at lower doses.
1 ml of solution MultiHance® contains: (0.5M) gadobenate dimeglumine 529 mg = gadobenic acid 334 mg + meglumine 195 mg. Viscosity at 37°C: 5.3 mPa

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.
Drug Information and Specification
NAME OF COMPOUND
Gadobenate dimeglumine, Gd-BOPTA, E7155
DEVELOPER
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, predominantly positive enhancement
r1=9.7, r2=12.5, B0=0.5 T
PHARMACOKINETIC
Extracellular, hepatobiliary
1970 mosm/kg
CONCENTRATION
334 mg/ml
DOSAGE
0.05 mmol/kg for Liver MRI
0.1 mmol/kg for CNS MRI
PREPARATION
Solution for injection
INDICATION
CNS, Liver MRI
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Vials of 5, 10, 15 and 20 mL, 50 and 100 mL Multipacks (Pharmacy Bulk Package)
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
EU
MultiHance®
for sale
USA
MultiHance®
for sale
Australia
MultiHance®
for sale
spacer

• View the DATABASE results for 'MultiHance®' (9).Open this link in a new window


• View the NEWS results for 'MultiHance®' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
MultiHance Package Insert(.pdf)
   by www.fda.gov    
  News & More:
FDA Expands Pediatric Age Range for MultiHance Contrast Agent
Tuesday, 30 January 2018   by www.empr.com    
MAGNETIC RESONANCE IMAGING OF FOCAL LIVER LESIONS(.pdf)
2002
BRACCO DIAGNOSTICS' MULTIHANCE EARNS FDA APPROVAL
Wednesday, 24 November 2004   by salesandmarketingnetwork.com    
MRI Resources 
Used and Refurbished MRI Equipment - Movies - Bioinformatics - Mobile MRI Rental - MRI Accidents - PACS
 
Nuclear Magnetic ResonanceMRI Resource Directory:
 - NMR -
 
(NMR) Nuclear Magnetic Resonance is a physical phenomenon of the magnetic property of nuclei, which have a positive nuclear spin quantum number.
Under the influence of an external static magnetic field this nuclei will precess about the direction of the magnetic field with an angular frequency (Larmor frequency). Through absorption and emission of RF energy (gradients, RF coils) at the resonance frequency (Larmor equation) and the processing of this raw data by the Fourier transformation - physical, chemical, electronic, and structural information about molecules can be obtained (NMR Magnetic Resonance Spectroscopy, Magnetic Resonance Imaging).
spacer

• View the DATABASE results for 'Nuclear Magnetic Resonance' (11).Open this link in a new window


• View the NEWS results for 'Nuclear Magnetic Resonance' (1).Open this link in a new window.
 
Further Reading:
  Basics:
MRI's inside story
Thursday, 4 December 2003   by www.economist.com    
Nuclear magnetic resonance with no magnets
Wednesday, 18 May 2011   by www.physorg.com    
  News & More:
Neuromelanin-Sensitive MRI Identified as a Potential Biomarker for Psychosis
Sunday, 10 February 2019   by www.nimh.nih.gov    
A powder to enhance NMR signals
Thursday, 12 December 2013   by phys.org    
New Paradigm for Nanoscale Resolution MRI Experimentally Achieved
Friday, 27 September 2013   by www.sciencedaily.com    
Searchterm 'Mole' was also found in the following services: 
spacer
News  (60)  Resources  (48)  Forum  (2)  
 
P792InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: P792, generic name: Gadomeritol, preliminary trade name: Vistaremâ„¢, central moiety: Gd
A macromolecular Gd-DOTA derivate under development as a MRI blood pool agent with rapid clearance. Phase II of the clinical trials on P792 (Guerbet SA) will make it possible to validate the performance of this agent in the fields of angiography, myocardial perfusion and tumor characterization.
spacer

• View the DATABASE results for 'P792' (2).Open this link in a new window


• View the NEWS results for 'P792' (1).Open this link in a new window.
 
Further Reading:
  News & More:
The Toolbox Indirectly, tissue is the issue
Searchterm 'Mole' was also found in the following services: 
spacer
Radiology  (17) Open this link in a new windowUltrasound  (18) Open this link in a new window
Perfusion AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Any molecule used to measure organ perfusion in conjunction with imaging.
Characteristics of good perfusion agents:
to be admitted by the perfused tissue in proportion to perfusion,
to remain strictly intravascular, or
diffuse freely throughout the tissue of interest.

Perfusion agents used in MRI are small Gd-chelates (they do not cross blood brain barrier, but extravasate quickly into extracellular space in other organs) and SPIOS.
spacer

• View the NEWS results for 'Perfusion Agents' (3).Open this link in a new window.
 
Further Reading:
  Basics:
EVALUATION OF HUMAN STROKE BY MR IMAGING
2000
MRI Resources 
Breast MRI - Jobs pool - Guidance - Process Analysis - Artifacts - Distributors
 
previous      66 - 70 (of 83)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 23 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]