Methods of selectively enhancing or suppressing the signal from a particular molecular substance by using its spin properties, typically through spin spin coupling, e.g. J-modulation.
Searchterm 'Mole' was also found in the following services:
Edward Purcell and Felix Bloch discovered the basic of spectroscopy in 1946 (see MRI History). Nuclear magnetic resonance spectroscopy (NMR Spectroscopy or MRS) is an analytical tool, based on nuclei that have a spin (nuclei with an odd number of neutrons and/or protons) like 1H, 13C, 17O, 19F, 31P etc.
Through nuclear magnetic principles as precession, chemical shift, spin spin coupling etc., the analysis of the content, purity, and molecular structure of a sample is possible. The spectrum produced by this process contains a number of peaks; the highs and the positions of these peaks allow the exact analysis. Unknown compounds can be matched against spectral libraries. Even very complex organic compounds as enzymes and proteins can be determined. For the wide uses of NMR spectroscopy (from mineralogy to medicine) there is a variety of different techniques available.
See Spectroscopic Imaging Techniques.
• View the DATABASE results for 'Spectroscopy' (90).
The international system for units.
Le Systeme international d'Unites officially came into being in October 1960 and has been adopted by nearly all countries, though the amount of actual usage varies considerably.
It is based upon 7 principal units:
Length - metre(m)
Mass - kilogram(kg)
Time - second(s)
Electric current - ampere(A)
Temperature - kelvin(K)
Amount of substance - mole(mol)
Luminous intensity - candela(cd)
From these basic units many other units are derived and named.
The T2relaxation time (spin spin relaxation time or transverse relaxation time), is a biological parameter that is used in MRIs to distinguish between tissue types and is termed 'Time 2' or T2. It is a tissue-specific time constant for protons and is dependent on the exchanging of energy with near by nuclei. T2 weighted images rely upon local dephasing of spins following the application of the transverse energy pulse. T2 is the decay of magnetization perpendicular to the main magnetic field (in an ideal homogeneous field).
Due to interaction between the spins, they lose their phase coherence, which results in a loss of transverse magnetization and MRI signal. After time T2transverse magnetization has lost 63% of its original value. This tissue parameter determines the contrast.
The T2 relaxation is temperature dependent. At a lower temperature molecular motion is reduced and the decay times are reduced.
Fat has a very efficient energy exchange and therefore it has a relatively short T2.
Water is less efficient than fat in the exchange of energy, and therefore it has a long T2 time.