Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Molecule' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Molecule' found in 1 term [] and 40 definitions []
previous     36 - 40 (of 41)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9]
Searchterm 'Molecule' was also found in the following services: 
spacer
News  (25)  Resources  (14)  Forum  (1)  
 
Pharmacyclics, Inc.MRI Resource Directory:
 - Manufacturers -
 
www.pcyc.com Pharmacyclics is a pharmaceutical company developing novel agents to improve current therapeutic approaches to cancer, cardiovascular diseases, and inflammation. The company's proprietary products are derived from its core technology in biometallic chemistry. These products under development are based upon small molecules, which bind metals in a unique way and are capable of capturing and focusing forms of energy used in a variety of medical applications. The company has one product in registration with the FDA, Gadolite® Oral Suspension, a contrast agent for imaging the gastrointestinal tract; two products in clinical development, Gd-Tex (Motexafin gadolinium), a radiation sensitizer, Lu-Tex, a photosensitizer; and several compounds in preclinical development.

MRI Contrast Agents:
Contact Information
MAIL
Pharmacyclics Inc.
995 East Arques Avenue
94085 Sunnyvale, California
USA
PHONE
+1-408-774-0330
FAX
+1-408-774-0340
spacer

• View the NEWS results for 'Pharmacyclics, Inc.' (5).Open this link in a new window.
 
Further Reading:
  News & More:
Pharmacyclics Receives Non-Approvable Letter from the FDA for Xcytrin for the Treatment of Lung Cancer Brain Metastases
Friday, 21 December 2007   by www.prnewswire.com    
Texaphyrin Compounds Visualize Vulnerable Plaque
Friday, 4 June 2004   by www.hospimedica.com    
Searchterm 'Molecule' was also found in the following services: 
spacer
Radiology  (10) Open this link in a new windowUltrasound  (5) Open this link in a new window
Quadrupole Moment
 
A measure of the non-spherical distribution of electrical charge possessed by nuclei with a nuclear spin number greater than 1/2. The resulting interaction with electric field gradients in the molecule can lead to a shortening of relaxation times and a broadening of spectral lines.
spacer
MRI Resources 
Examinations - MR Guided Interventions - Devices - Safety Products - Mobile MRI - Resources
 
Relaxation Effect
 
The relaxation effect is the transition of an atom or molecule from a higher energy level to a lower one. The return of the excited proton from the high energy to the low energy level is associated with the loss of energy to the surrounding tissue. The T1 and T2 relaxation times define the way that the protons return to their resting levels after the initial radio frequency (RF) pulse. The T1 and T2 relaxation rates have an effect of the signal to noise ratio (SNR) of MR images.
The relaxation process is a result of both T1 and T2, and can be controlled by the dependency of one of the two biological parameters T1 and T2 in the recorded signal. A T1 weighted spin echo sequence is based on a short repetition time (TR) and a change of it will affect the acquisition time and the T1 weighting of the image. Increased TR results in improved SNR caused by longer recovering time for the longitudinal magnetization. Increased TE improves the T2 weighting, combined with a long TR (of several T1 times) to minimize the T1 effect.
spacer

• View the DATABASE results for 'Relaxation Effect' (2).Open this link in a new window

 
Further Reading:
  News & More:
MRI's inside story
Thursday, 4 December 2003   by www.economist.com    
Searchterm 'Molecule' was also found in the following services: 
spacer
News  (25)  Resources  (14)  Forum  (1)  
 
Relaxivity
 
The ability of magnetic compounds to increase the relaxation rates of the surrounding water proton spins.
Relaxivity is used to improve the contrast of the image, and to study tissue specific areas where the contrast agent better diffuses or to perform functional magnetic resonance imaging.
The relaxivity of MRI contrast agents depends on the molecular structure and kinetic of the complex. To increase the number of water molecules that are in the inner sphere of the complex, or to slow down the molecular rotational correlation time, are possibilities to improve the water relaxivity.
Relaxivity units (r1, r2) are mM-1 * sec-1 (at varying temperatures).
spacer

• View the DATABASE results for 'Relaxivity' (51).Open this link in a new window


• View the NEWS results for 'Relaxivity' (2).Open this link in a new window.
 
Further Reading:
  News & More:
Measurements of the relaxivity of gadolinium chelates in tissues in vivo(.pdf)
2001   by cds.ismrm.org    
Searchterm 'Molecule' was also found in the following services: 
spacer
Radiology  (10) Open this link in a new windowUltrasound  (5) Open this link in a new window
Saturation Transfer
 
Nuclei can retain their magnetic orientation through a chemical reaction. Thus, if RF radiation is supplied to the spins at a frequency corresponding to the chemical shift of the nuclei in one chemical state so as to produce saturation or inversion, and chemical reactions transform the nuclei into another chemical state with a different chemical shift in a time short compared to the relaxation time, the NMR spectrum may show the effects of the saturation or inversion on the corresponding, unirradiated line in the spectrum. This technique can be used to study reaction kinetics of suitable molecules.
spacer

• View the DATABASE results for 'Saturation Transfer' (3).Open this link in a new window

 
Further Reading:
  Basics:
Researchers create novel way to enhance MRI
Tuesday, 30 April 2013   by www.news-medical.net    
  News & More:
New Brain Imaging Technique Identifies Previously Undetected Epileptic Seizure Sites
Friday, 13 November 2015   by www.newswise.com    
MRI Resources 
Claustrophobia - Used and Refurbished MRI Equipment - Spectroscopy - Collections - General - Veterinary MRI
 
previous      36 - 40 (of 41)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]