Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Radio Frequency Pulse' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Radio Frequency Pulse' found in 2 terms [] and 21 definitions []
1 - 5 (of 23)     next
Result Pages : [1]  [2 3 4 5]
Searchterm 'Radio Frequency Pulse' was also found in the following service: 
spacer
Resources  (1)  
 
Radio Frequency Pulse
 
A pulse is a rapid change in the amplitude of a RF signal or in some characteristic a RF signal, e.g., phase or frequency, from a baseline value to a higher or lower value, followed by a rapid return to the baseline value. For radio frequencies near the Larmor frequency, it will result in rotation of the macroscopic magnetization vector. The amount of rotation will depend on the strength and duration of the RF pulse; commonly used examples are 90° (p/2) and 180° (p) pulses.
RF pulses are used in the spin preparation phase of a pulse sequence, which prepare the spin system for the ensuing measurements. In many sequences, RF pulses are also applied to the volumes outside the one to be measured. This is the case when spatial presaturation techniques are used to suppress artifacts. Many preparation pulses are required in MR spectroscopy to suppress signal from unwanted spins. The simplest preparation pulse making use of spectroscopic properties is a fat saturation pulse, which specifically irradiates the patient at the fat resonant frequency, so that the magnetization coming from fat protons is tilted into the xy-plane where it is subsequently destroyed by a strong dephasing gradient.
The frequency spectrum of RF pulses is critical as it determines the spatial extension and homogeneity over which the spin magnetization is influenced while a gradient field is applied.
spacer
 
• Share the entry 'Radio Frequency Pulse':  Facebook  Twitter  LinkedIn  
 
• Related Searches:
    • Pulse Sequence
    • Spin Echo
    • Coil
    • Echo Spacing
    • Larmor Frequency
 
Further Reading:
  News & More:
MRI Safety: Monitoring Body Temperature During MRI
Thursday, 4 August 2011   by www.diagnosticimaging.com    
MRI Resources 
MRI Reimbursement - Breast Implant - Bioinformatics - Jobs - Safety Products - MR Guided Interventions
 
Adiabatic Radio Frequency Pulses
 
Adiabatic RF pulses are amplitude and frequency modulated pulses that are insensitive to the effects of B1-inhomogeneity and frequency offset (conventional RF pulses used in MRI are only amplitude modulated). Due to an extended application time adiabatic RF pulses are mostly used in NMR imaging applications.
spacer

• View the DATABASE results for 'Adiabatic Radio Frequency Pulses' (2).Open this link in a new window

MRI Resources 
Services and Supplies - Sequences - Intraoperative MRI - Blood Flow Imaging - Directories - Musculoskeletal and Joint MRI
 
Cardiac StentForum -
related threadsMRI Resource Directory:
 - Safety -
 
The MRI safety of cardiac stents is dependent of the material, the examined part of the body and the used field strength. A susceptibility artifact is expected also in low magnetic fields, but less.
mri safety guidance
MRI Safety Guidance
Most of the used materials are non-magnetic, for this case there is no risk for movement caused through the magnetic field. If the cardiac stent is outside the region of the radio frequency pulse, also the risk of e.g. heating is low.
spacer

• View the DATABASE results for 'Cardiac Stent' (4).Open this link in a new window

 
Further Reading:
  Basics:
Guidelines for the Management of Patients with Coronary Artery Stents Referred for MRI Procedures
Tuesday, 1 January 2019   by www.ismrm.org    
Searchterm 'Radio Frequency Pulse' was also found in the following service: 
spacer
Resources  (1)  
 
Carr Purcell Meiboom Gill SequenceInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:
 - Sequences -
 
(CPMG) This type of spin echo pulse sequence consisting of a 90° radio frequency pulse followed by an echo train induced by successive 180° pulses and is useful for measuring T2 weighted images. It is a modification of the Carr-Purcell RF pulse sequence, with 90° phase shift in the rotating frame of reference between the 90° pulse and the subsequent 180° pulses in order to reduce accumulating effects of imperfections in the 180° pulses. Suppression of effects of pulse error accumulation can alternatively be achieved by switching phases of the 180° pulses by 180°.
 
Images, Movies, Sliders:
 MRI - Anatomic Imaging of the Ankle 1  Open this link in a new window
    
SlidersSliders Overview

 Anatomic MRI of the Neck  Open this link in a new window
    
SlidersSliders Overview

 
spacer

• View the DATABASE results for 'Carr Purcell Meiboom Gill Sequence' (2).Open this link in a new window

 
Further Reading:
  Basics:
Fast Spin Echo(.pdf)
Tuesday, 24 January 2006   by www.81bones.net    
Magnetic resonance imaging
   by www.scholarpedia.org    
  News & More:
Spin echoes, CPMG and T2 relaxation - Introductory NMR & MRI from Magritek
2013   by www.azom.com    
MRI Resources 
Education pool - Breast MRI - Education - Pregnancy - Equipment - Mass Spectrometry
 
Excitation
 
Sent (inducing, transferring) energy into the 'spinning' nuclei via radio frequency pulse, which puts the nuclei into a higher energy state. By producing a net transverse magnetization a MRI system can observe a response from the excited system.
spacer

• View the DATABASE results for 'Excitation' (108).Open this link in a new window

 
Further Reading:
  Basics:
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Sunday, 1 August 2004   by www.ajronline.org    
IMAGE CONTRAST IN MRI(.pdf)
   by www.assaftal.com    
MRI Resources 
Cardiovascular Imaging - Shoulder MRI - Non-English - Supplies - Software - Intraoperative MRI
 
     1 - 5 (of 23)     next
Result Pages : [1]  [2 3 4 5]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]