Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Relaxation Time' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Relaxation Time' found in 5 terms [] and 52 definitions []
previous     31 - 35 (of 57)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11 12]
Searchterm 'Relaxation Time' was also found in the following services: 
spacer
News  (3)  Resources  (2)  Forum  (6)  
 
Inversion RecoveryForum -
related threads
 
(IR) Inversion recovery is an MRI technique, which can be incorporated into MR imaging, wherein the nuclear magnetization is inverted at a time on the order of T1 before the regular imaging pulse-gradient sequences. The resulting partial relaxation of the spins in the different structures being imaged can be used to produce an image that depends strongly on T1. This may bring out differences in the appearance of structures with different T1 relaxation times. Note that this does not directly produce an image of T1. T1 in a given region can be calculated from the change in the MR signal from the region due to the inversion pulse compared to the signal with no inversion pulse or an inversion pulse with a different inversion time. This sequence involves successive 180° and 90° pulses. The inversion recovery sequence is specified in terms of three parameters, inversion time (TI), repetition time (TR) and echo time (TE).

See also Inversion Recovery Sequence and FLAIR.
 
Images, Movies, Sliders:
 Brain MRI Inversion Recovery  Open this link in a new window
    
 Knee MRI Sagittal STIR 002  Open this link in a new window
    
 Brain MRI Coronal FLAIR 001  Open this link in a new window
 
spacer
 
• Related Searches:
    • Spectral Selection Attenuated Inversion Recovery
    • Knee MRI
    • Imaging of the Extremities
    • Spectral Presaturation Inversion Recovery
    • Flow Sensitive Alternating Inversion Recovery
 
Further Reading:
  Basics:
T1-weighted Phase Sensitive Inversion Recovery for Imaging Multiple Sclerosis Lesions in the Cervical Spinal Cord(.pdf)
   by www.healthcare.siemens.com    
Contrast mechanisms in magnetic resonance imaging
2004   by www.iop.org    
  News & More:
Artificial double inversion recovery images can substitute conventionally acquired images: an MRI-histology study
Wednesday, 16 February 2022   by www.nature.com    
Accurate T1 Quantification Using a Breath-hold Inversion Recovery TrueFISP Sequence
2003   by rsna2003.rsna.org    
MRI Resources 
Breast Implant - Universities - Implant and Prosthesis - Journals - MRCP - Case Studies
 
Inversion Recovery Spin Echo
 
(IRSE) Form of inversion recovery imaging in which the signal is detected as a spin echo. For TE short compared to the T2 relaxation time, there will be only a small effect of T2 differences on image intensities; for longer TE's, the effect of T2 may be significant.
spacer
 
Further Reading:
  Basics:
Magnetic resonance imaging
   by www.scholarpedia.org    
MRI Resources 
Examinations - Online Books - PACS - Corporations - MRI Physics - Image Quality
 
Longitudinal Relaxation Rate
 
(R1/R2) The longitudinal relaxation rate is equal to reciprocal of relaxation time.
spacer

• View the DATABASE results for 'Longitudinal Relaxation Rate' (3).Open this link in a new window

 
Further Reading:
  Basics:
Measuring T1 and T2 Relaxation - Introductory NMR & MRI from Magritek
   by www.azom.com    
Searchterm 'Relaxation Time' was also found in the following services: 
spacer
News  (3)  Resources  (2)  Forum  (6)  
 
Low Field MRIForum -
related threads
 
Advantages of low field imaging are the small-sized 5 Gauss fringe field and therefore the less static magnetic field exposure for the surrounding area, as well as less contraindications causing lower risks for the MRI safety by implemented metal and magnetic devices and equipment.
Low field systems are sometimes for restricted use, e.g. dedicated extremity scanner or open MRI devices. Open MRI devices equipped with permanent magnets are well-suited for MR guided interventions because these machines combine the lower magnetic fields of this type of magnets and the better patient access of open MRI scanner.
In some cases, the contrast of different tissues is better at lower field strength, depending on their T1 or T2 relaxation times. The disadvantage of the lower signal to noise ratio are a poor resolution and a longer scan time for a good image quality.

See also Claustrophobia, Contraindications and MRI Safety.

See also the related poll result: 'In 2010 your scanner will probably work with a field strength of'
spacer

• View the DATABASE results for 'Low Field MRI' (8).Open this link in a new window


• View the NEWS results for 'Low Field MRI' (5).Open this link in a new window.
 
Further Reading:
  Basics:
Improving portable low-field MRI image quality through image-to-image translation using paired low- and high-field images
Friday, 1 December 2023   by www.nature.com    
  News & More:
Safety of Bedside Portable Low-Field Brain MRI in ECMO Patients Supported on Intra-Aortic Balloon Pump
Friday, 18 November 2022   by www.mdpi.com    
Researchers at the University of Tsukuba develop a portable MRI system specifically for identifying wrist cartilage damage among athletes, providing a convenient means of early detection and treatment of injuries
Tuesday, 26 April 2022   by www.tsukuba.ac.jp    
This bizarre looking helmet can create better brain scans
Friday, 11 February 2022   by www.sciencedaily.com    
A low-cost and shielding-free ultra-low-field brain MRI scanner
Tuesday, 14 December 2021   by www.nature.com    
Portable MRI provides life-saving information to doctors treating strokes
Thursday, 5 August 2021   by news.yale.edu    
Synaptive Evry, an MRI for Any Space, Cleared by FDA
Thursday, 30 April 2020   by www.medgadget.com    
World's First Portable MRI Cleared by FDA
Monday, 17 February 2020   by www.medgadget.com    
Introducing a point-of-care MRI system
Tuesday, 29 October 2019   by healthcare-in-europe.com    
Opportunities in Interventional and Diagnostic Imaging by Using High-performance Low-Field-Strength MRI
Tuesday, 1 October 2019   by pubs.rsna.org    
Portable 'battlefield MRI' comes out of the lab
Thursday, 30 April 2015   by physicsworld.com    
Portable MRI could aid wounded soldiers and children in the third world
Thursday, 23 April 2015   by phys.org    
MRI Resources 
Jobs pool - Research Labs - Journals - MRI Technician and Technologist Jobs - Supplies - Service and Support
 
LumenHance®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Oral administration of this liposomal encapsulated manganese chloride results in a reduction of the T1 relaxation time causing enhanced signal on T1 weighted MR images. Bracco received marketing approval in December 1997 in the United States, but marketing state is still uncertain.

See also Classifications, Characteristics, etc.
Drug Information and Specification
NAME OF COMPOUND
MnCl2, Manganese chloride tetrahydrate
CENTRAL MOIETY
Mn2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
Paramagnetic
PHARMACOKINETIC
Gastrointestinal
PREPARATION
Powder for reconstitution
INDICATION
Bowel marking
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
LumenHance®
for sale
spacer

• View the DATABASE results for 'LumenHance®' (4).Open this link in a new window

MRI Resources 
Veterinary MRI - Spectroscopy pool - Stimulator pool - MRCP - - Examinations
 
previous      31 - 35 (of 57)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11 12]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 23 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]