Radio Frequency CoilInfoSheet: - Coils - 
Intro, 
Overview, 
etc.MRI Resource Directory:
 - Coils -
 
A coil is a large inductor with a considerable dimension and a defined wavelength, commonly used in configurations for MR imaging. The frequency of the radio frequency coil is defined by the Larmor relationship.
The MRI image quality depends on the signal to noise ratio (SNR) of the acquired signal from the patient. Several MR imaging coils are necessary to handle the diversity of applications. Large coils have a large measurement field, but low signal intensity and vice versa (see also coil diameter). The closer the coil to the object, the stronger the signal - the smaller the volume, the higher the SNR. SNR is very important in obtaining clear images of the human body. The shape of the coil depends on the image sampling. The best available homogeneity can be reached by choice of the appropriate coil type and correct coil positioning. Orientation is critical to the sensitivity of the RF coil and therefore the coil should be perpendicular to the static magnetic field.

RF coils can be differentiated by there function into three general categories:
The RF signal is in the range of 10 to 100 MHz. During a typical set of clinical image measurements, the entire frequency spectrum of interest is of the order 10 kHz, which is an extremely narrow band, considering that the center frequency is about 100 MHz. This allows the use of single-frequency matching techniques for coils because their inherent bandwidth always exceeds the image bandwidth. The multi turn solenoid, bird cage coil, single turn solenoid, and saddle coil are typically operated as the transmitter and receiver of RF energy. The surface and phased array coils are typically operated as a receive only coil.

See also the related poll result: '3rd party coils are better than the original manufacturer coils'
 
Images, Movies, Sliders:
 Circle of Willis, Time of Flight, MIP  Open this link in a new window
    
SlidersSliders Overview

 Anatomic MRI of the Knee 1  Open this link in a new window
    
SlidersSliders Overview

 
spacer
 
• Related Searches:
    • Bird Cage Coil
    • Coil Diameter
    • Hardware
    • Signal to Noise Ratio
    • Gradient Coil
 
Further Reading:
  Basics:
Radio-frequency Coil Selection for MR Imaging of the Brain and Skull Base1
   by radiology.rsnajnls.org    
  News & More:
High-field MRI Coils – that work, superbly, even at 750 MHz
   by www.dotynmr.com    
Magnetic resonance-guided motorized transcranial ultrasound system for blood-brain barrier permeabilization along arbitrary trajectories in rodents
Thursday, 24 December 2015   by www.ncbi.nlm.nih.gov    
MRI Resources 
Service and Support - Implant and Prosthesis - MR Myelography - MR Guided Interventions - Databases - Crystallography
 
Receiver CoilInfoSheet: - Coils - 
Intro, 
Overview, 
etc.MRI Resource Directory:
 - Coils -
 
A coil, or antenna, positioned within the imaging volume and connected to the receiver circuitry that is used to detect or receive the MR signal from the patient as the disturbed spins relax back into their equilibrium distribution. Also called receive-only coil.
Special-purpose coils are designed to optimize the SNR from a given region of the body. State-of-the-art coil systems include the use of four or more coils with four separate receivers. This method is often referred to as a phased array system. Receiver coil types include also solenoid, planar, volume and quadrature coils. The quality of the MR images depends on the SNR of the acquired signal from the patient. SNR is of the utmost importance in obtaining clear images of the interior of the human body.
spacer

• View the DATABASE results for 'Receiver Coil' (11).Open this link in a new window

MRI Resources 
Artifacts - Crystallography - MR Guided Interventions - Societies - PACS - Breast Implant
 
Array CoilInfoSheet: - Coils - 
Intro, 
Overview, 
etc.MRI Resource Directory:
 - Coils -
 
An array coil combines the advantages of smaller coils (high SNR) with those of larger coils (large measurement field). This type of RF coil is composed of separate multiple smaller coils, which can be used individually (switchable coil) or combined.
When used simultaneously, the elements can either be:
coupled array coils - electrically coupled to each other through common transmission lines or mutual inductance
isolated array coils - electrically isolated from each other with separate transmission lines and receivers and minimum effective mutual inductance, and with the signals from each transmission line processed independently or at different frequencies
phased array coils - multiple small coils arranged to efficiently cover a specific anatomic region and obtain high-resolution, high-SNR images of a larger volume. The data from the individual coils is integrated by special software to produce the high-resolution images.

See also the related poll result: '3rd party coils are better than the original manufacturer coils'
 
Images, Movies, Sliders:
 Anatomic Imaging of the Lumbar Spine  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 
spacer

• View the DATABASE results for 'Array Coil' (22).Open this link in a new window


• View the NEWS results for 'Array Coil' (1).Open this link in a new window.
 
Further Reading:
  News & More:
3T MRI-Compatible Small Body Array Gets FDA Nod
Monday, 15 January 2024   by www.diagnosticimaging.com    
Endorectal Coil Improves Prostate Cancer Detection
Friday, 25 November 2005   by www.sciencedaily.com    
Searchterm 'SNR' was also found in the following services: 
spacer
News  (3)  Forum  (11)  
 
Coil DiameterInfoSheet: - Coils - 
Intro, 
Overview, 
etc.
 
MRI coils with a small diameter obtain a higher signal to noise ratio (SNR) than coils with a large diameter. A surface coil with a small diameter can be used to improve the resolution because the area of interest is around the optimal signal depth. The field of view of a (superficial) surface coil is half the diameter of the coil. A disadvantage is a lower sensitive volume of the coil. By combining several coils with small diameters (phased array coil) to record the signal simultaneously and independently, the SNR level improves considerably.
spacer

• View the DATABASE results for 'Coil Diameter' (3).Open this link in a new window

MRI Resources 
Pediatric and Fetal MRI - MRI Training Courses - Case Studies - Veterinary MRI - Safety pool - Claustrophobia
 
Daily Quality AssuranceMRI Resource Directory:
 - Quality Advice -
 
(DQA) This MRI scan or MRI procedure is used by system operators to verify system operation based on relevant image quality parameters like e.g., SNR, slice thickness, geometric distortion, slice position, image resolution and ghosting.
The quality assurance should carry out according to instructions of the manufacturer, normally using the head coil. In addition, SNR can be measured monthly on a selection of commonly used coils. Weekly recording of these parameters is recommended for clinical MRI machines, as this allows early detecting of deviations from acceptable limits.
spacer

• View the DATABASE results for 'Daily Quality Assurance' (3).Open this link in a new window

 
Further Reading:
  News & More:
MRI Quality Control Program
   by www.simplyphysics.com    
MRI Resources 
Services and Supplies - Safety pool - Intraoperative MRI - Open Directory Project - Veterinary MRI - Musculoskeletal and Joint MRI
 
previous      6 - 10 (of 46)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]