Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Scan Time' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Scan Time' found in 1 term [] and 48 definitions []
previous     46 - 49 (of 49)     
Result Pages : [1]  [2 3 4 5 6 7 8 9 10]
Searchterm 'Scan Time' was also found in the following services: 
spacer
News  (25)  Resources  (3)  Forum  (13)  
 
Time to Repetition
 
TR is the pulse sequence repetition time. It is delineated by initiating the first RF pulse of the sequence then repeating the same RF pulse at a time t. Variations in the value of TR have an important effect on the control of image contrast characteristics. This formula is directly derived from the Bloch equations.

See also Scan Time.
spacer
MRI Resources 
Developers - Artifacts - Implant and Prosthesis - Patient Information - MRI Reimbursement - MRI Centers
 
Tip Angle
 
Angle between the net magnetization vector before and after a RF excitation pulse. Small tip angles allow a decrease in TR, which is used to decrease scan time in Field Echo pulse sequences. See Flip Angle.
spacer

• View the DATABASE results for 'Tip Angle' (5).Open this link in a new window

 
Further Reading:
  Basics:
Mapping of low flip angles in magnetic resonance(.pdf)
Saturday, 1 January 2011   by www.hal.inserm.fr    
MRI Resources 
Spectroscopy - MRI Reimbursement - Contrast Agents - Homepages - Most Wanted - Coils
 
Undersampling
 
Undersampling is the decrease in data to increase image acquisition speed (shorter scan times without loss of quality - increased productivity - reduced cost of equipment). There are different strategies to decrease data without losing quality (e.g. reduction of the FOV in one or more spatial directions - RFOV).
Reduction in data normally is associated with an increase in aliasing (degradation of the SNR through backfolding of the entire noise spectrum), or with other artifact caused by missing data, which results in fine lines.
spacer

• View the DATABASE results for 'Undersampling' (6).Open this link in a new window

Searchterm 'Scan Time' was also found in the following services: 
spacer
News  (25)  Resources  (3)  Forum  (13)  
 
Volumetric Imaging
 
Volumetric imaging is a 3D technique where all the MRI signals are collected from the entire tissue sample and imaged as a whole entity, therefore providing a high signal to noise ratio. The acquisition of isotropic voxels or thin slices with high spatial resolution allows to create multiplanar reconstructions in all planes; a compensation for the usually longer scan time. The acquisition time can be reduced by parallel imaging technique.
New T2 weighted variants of 3D sequences (FSE-XETA, T2-SPACE, VISTA) have been introduced that differ from conventional FSE sequences. An echo train containing up to 200 echoes obtained at a minimum echo spacing allows very fast acquisition. A flip angle modulation (flip angle sweep - FAS) during the FSE readout carries magnetization as long as possible to avoid blurring and provide optimal signal at the effective echo time. This type of imaging is well suited for brain and spine MRI procedures.
Newer T1 weighted variants include Liver Acquisition with Volume Acquisition (LAVA) and T1W High Resolution Isotropic Volume Examination (THRIVE), which have advantages for dynamic breath hold imaging in liver and abdominal examinations.

See also Volume Imaging, 3 Dimensional Imaging.
 
Images, Movies, Sliders:
 Brain MRI Sagittal T1 001  Open this link in a new window
    
 Circle of Willis, Time of Flight, MIP  Open this link in a new window
    
SlidersSliders Overview

 MRI of the Skull Base  Open this link in a new window
    
SlidersSliders Overview

 
spacer

• View the DATABASE results for 'Volumetric Imaging' (4).Open this link in a new window


• View the NEWS results for 'Volumetric Imaging' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Cutting Edge Imaging of THE Spine
February 2007   by www.pubmedcentral.nih.gov    
3-D VOLUMETRIC IMAGING FOR STEREOTACTIC LESIONAL AND DEEP BRAIN STIMULATION SURGERY
MRI Resources 
Quality Advice - Contrast Enhanced MRI - Open Directory Project - Resources - Diffusion Weighted Imaging - Societies
 
previous      46 - 49 (of 49)     
Result Pages : [1]  [2 3 4 5 6 7 8 9 10]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]