Magnetic
Resonance -
Technology
Information
Portal |
Welcome to MRI Technology • |
|
|
 | Info Sheets |
| | | | | | | | | | | | | | | | | | | | | | | | |
 | Out- side |
| | | | |
|
| | | | |
Result : Searchterm 'Shim Coils' found in 1 term [ ] and 6 definitions [ ], (+ 19 Boolean[ ] results
| 1 - 5 (of 26) nextResult Pages : [1] [2] [3 4 5 6] |  | | |  |  |  |
Shim Coils |   |
| |
|
Coils carrying a relatively small current that are used to provide auxiliary magnetic fields in order to compensate for inhomogeneities in the main magnetic field of a MR system. See also Shimming. | |  | | | • Share the entry 'Shim Coils': | | | | | | | | |
|  | |  |  |  |
| |
|
| |  | | • View the DATABASE results for 'Active Shimming' (4).
| | | | Further Reading: | | Basics:
|
|
News & More:
| |
| |
|  | |  |  |  |
| |
|
A refrigeration unit that supplies cold water used to cool MRI components. Depending on the system configuration chillers are used to cool shield coolers, shim coils and sometimes the air conditioning. | |  | | • View the DATABASE results for 'Chiller' (2).
| | | | Further Reading: | News & More:
|
|
| |
|  | |  |  |  |
| |
|
| |  | | • View the DATABASE results for 'Coil' (193).
| | | • View the NEWS results for 'Coil' (11).
| | | | Further Reading: | News & More:
|
 |
3T MRI-Compatible Small Body Array Gets FDA Nod Monday, 15 January 2024 by www.diagnosticimaging.com |  |  |
High-field MRI Coils – that work, superbly, even at 750 MHz
by www.dotynmr.com |  |  |
New superconducting coil improves MRI performance Wednesday, 20 July 2016 by www.eurekalert.org |  |  |
First European fully superconductive coil reaching a magnetic field of 25 Tesla produced Wednesday, 8 June 2016 by www.news-medical.net |  |  |
ScanMed Introduces a Groundbreaking New Orbit and Mandible Array to the MRI Market Wednesday, 26 March 2014 by www.digitaljournal.com |  |  |
MRI coil optimized for imaging of infants gets FDA clearance Tuesday, 17 April 2012 by www.medcitynews.com |  |  |
Low-profile MRI coil company inching toward commercialization Wednesday, 21 December 2011 by www.medcitynews.com |  |  |
High-Resolution Uniform MR Imaging of Finger Joints Using a Dedicated RF Coil at 3 Tesla Sunday, 31 January 2010 by www.ncbi.nlm.nih.gov |  |  |
DOTmed Industry Sector Report: MRI Coil Sales & Service Companies Thursday, 13 December 2007 by www.dotmed.com |
|
| |
|  | |  |  |  |
| |
|

From Siemens Medical Systems;
The MAGNETOM 7T is designed as an open research platform. 7T MRI provides anatomical detail at the submillimiter scale, enhanced contrast mechanisms, outstanding spectroscopy performance, ultra-high resolution functional imaging ( fMRI), multinuclear whole-body MRI and functional information.
This ultra high field (UHF) MRI device is a research system and not cleared, approved or licensed in any jurisdiction for patient examinations.
Device Information and Specification
CLINICAL APPLICATION
Whole body
High-performance, ultra high field coils available. Integration and support for coil developments.
CHANNELS (min. / max. configuration)
32, optional 8 channels TX array
40 x 40 x 30 cm³ less than 8% nonlinearity
MAGNET WEIGHT (gantry included)
35017 kg
DIMENSION H*W*D (gantry included)
320 x 240 x 317,5 cm
MAX. AMPLITUDE
up to 70 mT/m
Up to 3rd order shim coils, user configurable B0 shim ? B0 maps and ROI definition
POWER REQUIREMENTS
2000 Volts, 650A
| |  | | | Further Reading: | Basics:
|
|