Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Siemens Medical Systems' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Siemens Medical Systems' found in 1 term [] and 21 definitions []
previous     16 - 20 (of 22)     next
Result Pages : [1]  [2 3 4 5]
Searchterm 'Siemens Medical Systems' was also found in the following services: 
spacer
News  (3)  Resources  (11)  
 
MAGNETOM Sonataâ„¢InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.med.siemens.com/med/d/gg/mr/products/sonata.html From Siemens Medical Systems;
while older navigator techniques take up to 40 minutes to create, the high performance of the MAGNETOM Sonata system enables 'complete examinations in less than 15 minutes'. It creates a new standard of diagnostic confidence and moves Cardiac MR from the research setting into routine clinical practice.
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Compact
Yes/SVS or CSI opt.
SYNCHRONIZATION
ECG/peripheral, respiratory gating
PULSE SEQUENCES
GRE, IR, FIR, STIR, TrueIR/FISP, FSE, FLAIR, MT, SS-FSE, MT-SE, MTC, MSE, EPI, 3D DESS//CISS/PSIF, GMR
IMAGING MODES
Single, multislice, volume study, multi angle, multi oblique
TR
1.5 msec at 256matrix
TE
0.58 msec at 256matrix
SINGLE/MULTI SLICE
178 images/sec at 256 x 256 at 100% FOV
0.5 cm - 40 cm
Min 2D/3D: 0.1/0.05 mm
1024 x 1024 full screen display
MEASURING MATRIX
64 x 64 to 1024 x 1024
PIXEL INTENSITY
10 micrometer in plane
60 cm
MAGNET WEIGHT
4050kg, 5500kg in operation
H*W*D
236 x 215 x 160 cm
POWER REQUIREMENTS
380/400/420/440/480 V
COOLING SYSTEM TYPE
Single cryogen, 2 stage refrig.
Liquid He
STRENGTH
40/70 mT/m
5-GAUSS FRINGE FIELD
2.5 m / 4.0 m
Passive, act.; 1st order std./2nd opt.
spacer
 
• Related Searches:
    • MRI Equipment
    • Device
    • Hardware
    • Low Field MRI
    • High Field MRI
Searchterm 'Siemens Medical Systems' was also found in the following services: 
spacer
Radiology  (1) Open this link in a new windowUltrasound  (15) Open this link in a new window
MAGNETOM Spectra
 
www.healthcare.siemens.com/magnetic-resonance-imaging/3t-mri-scanner/magnetom-spectra From Siemens Medical Systems;
Received FDA clearance in 2012.
The MAGNETOM Spectra is a cost-optimized high field MRI system with Tim 4G and Dot technologies. The system consumes less energy compared to other 3 Tesla scanners. The magnet-cooling helium is contained in a closed loop, which prevents the gas from escaping and reduces the need for refills. TimTX includes innovative techniques in the radio frequency excitation hardware as well as new application and processing features enabling uniform RF distribution in all body regions.
Device Information and Specification
CLINICAL APPLICATION
Whole Body
CONFIGURATION
Short bore
3 Tesla
Head, spine, torso/ body coil, neurovascular, neck and multi-purpose flex coils. Peripheral vascular, breast, shoulder, knee, wrist, foot//ankle, endorectal optional.
CHANNELS
24
Chemical shift imaging, single voxel spectroscopy
IMAGING TECHNIQUES
iPAT, mSENSE and GRAPPA (image, k-space), noncontrast angiography, radial motion compensation
FOV
0.5 - 45 cm
BORE DIAMETER
or W x H
At isocenter: L-R 60 cm
TABLE CAPACITY
200 kg
MAGNET WEIGHT
7200 kg
DIMENSION H*W*D (gantry included)
173 x 231 x 219 cm
5-GAUSS FRINGE FIELD
2.6 m / 4.6 m
CRYOGEN USE
Zero boil off rate, approx. 10 years
COOLING SYSTEM
Water; single cryogen, 2 stage refrigeration
up to 125 T/m/s
MAX. AMPLITUDE
33 mT/m
Passive, active; first order standard, second order optional
POWER REQUIREMENTS
380 / 400 / 420 / 440 / 460 / 480 V, 3-phase + ground; connection value with chiller 100 kvA /without chiller 60 kVA
spacer
MRI Resources 
Implant and Prosthesis - - Abdominal Imaging - Pathology - Safety Training - Safety Products
 
MAGNETOM Symphonyâ„¢InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.med.siemens.com/med/d/gg/mr/products/symphony1.html From Siemens Medical Systems;
with the introduction of this system, it is possible to perform contrast MR angiography for abdominal, thoracic and neck vessels from the origins to the circle of Willis. The system also has many newer features including functional imaging, spectroscopy, advanced body, ortho- and neuroimaging.
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Compact
Yes/SVS or CSI opt.
SYNCHRONIZATION
ECG/peripheral, respiratory gating
PULSE SEQUENCES
GRE, IR, FIR, STIR, TrueIR/FISP, FSE, FLAIR, MT, SS-FSE, MT-SE, MTC, MSE, EPI, GMR, fat/water sat./exc.
IMAGING MODES
Single, multislice, volume study, multi angle, multi oblique
TR
2.4 msec std.; 2.0 opt.; 1.8 w/30 mT/m at 256matrix
TE
1.1 msec std.; 0.9 opt.; 0.78 w/30 mT/m at 256matrix
SINGLE/MULTI SLICE
178 images/sec at 256 x 256 at 100% FOV
0.5 cm - 50 cm
Min 2D/3D: 0.1/0.05 mm
1024 x 1024 full screen display
MEASURING MATRIX
64 x 64 to 1024 x 1024
PIXEL INTENSITY
21 micrometer in plane, 11 micrometer optional
60 cm
MAGNET WEIGHT
4050kg, 5500kg in operation
H*W*D
236 x 215 x 160 cm w/covers
POWER REQUIREMENTS
380/400/420/440/480 V
COOLING SYSTEM TYPE
Single cryogen, 2 stage refrig.
Liquid He
STRENGTH
20/35 mT/m standard, 30/52 opt.
5-GAUSS FRINGE FIELD
2.5 m / 4.0 m
Passive, act.; 1st order std./2nd opt.
spacer

• View the DATABASE results for 'MAGNETOM Symphony™' (2).Open this link in a new window

 
Further Reading:
  Basics:
Symphony Brochure(.pdf)
Searchterm 'Siemens Medical Systems' was also found in the following services: 
spacer
News  (3)  Resources  (11)  
 
MAGNETOM Trioâ„¢ (TIM System)InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.
 
www.medical.siemens.com/webapp/wcs/stores/servlet/ProductDisplay?storeId=10001&langId=-11&catalogId=-11&catTree=100001%2C12786%2C12754&level=0&productId=145739 From Siemens Medical Systems;
The Magnetom Trio™, a 3T whole body MRI system with Tim (total imaging matrix technology), targets clinical applications such as abdominal, cardiac, spine, whole body and orthopedics. TIM enables flexible coil combinations for high resolution imaging of large anatomical areas without the need to change coils.
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Short bore
CP head, CP integrated body coil, neck matrix, breast array, 8-channel knee array, CP wrist, shoulder array, CP extremity
Yes/Mutli-nuclear MRS
PULSE SEQUENCES
SE, IR, 2D/3D TurboSE, Turbo IR, Dark-Fluid IR, True IR, 2D/3D MEDIC, 2D/3D GRE FLASH, 2D/3D GRE FISP, 2D/3D PSIF, 2D TurboFLASH, 3D MP-RAGE, 3D TurboFLASH, 2D/3D TOF angiography, MTC, TONE with 3D TOF MRA, GMR, LOTA
IMAGING MODES
Single, multislice, volume study, multi angle, multi oblique
SINGLE/MULTI SLICE
178 images/sec at 256 x 256 at 100% FOV
40 cm
Min 2D/3D: 0.1/0.05 mm
1024 x 1024 full screen display
MEASURING MATRIX
64 x 64 to 1024 x 1024
10 micrometer
60 cm
MAGNET WEIGHT
12000 kg
H*W*D
221 x 244 x 213 cm
POWER REQUIREMENTS
380/400/420/440/480 V
COOLING SYSTEM TYPE
Single cryogen, 2 stage refrig.
0.12 L/hr helium
STRENGTH
40 - 45 mT/m
200 mT/m/ms
5-GAUSS FRINGE FIELD
3.4 m / 5.9 m
Passive, act.; 1st order std./2nd opt.
spacer
Searchterm 'Siemens Medical Systems' was also found in the following services: 
spacer
Radiology  (1) Open this link in a new windowUltrasound  (15) Open this link in a new window
MAGNETOM Verio
 
www.healthcare.siemens.com/magnetic-resonance-imaging/3t-mri-scanner/magnetom-verio From Siemens Medical Systems;
Received FDA clearance in 2007.
The MAGNETOM Verio provides up to 102 integrated matrix coil elements and up to 32 independent radiofrequency channels that allow flexible coil combinations to make patient and coil repositioning virtually unnecessary. The Tim (total imaging matrix) technology also increases patient throughput due to a shorter scan time.
The open bore design offers great comfort for patients of all shapes and sizes.
Device Information and Specification
CLINICAL APPLICATION
Whole Body
CONFIGURATION
Ultra-short open bore
3 Tesla
Head, spine, torso/ body coil, neurovascular, cardiac, neck and multi-purpose flex coils. Peripheral vascular, breast, shoulder, knee, wrist, foot//ankle, TMJ optional.
CHANNELS (min. / max. configuration)
8, 18, 32
Chemical shift imaging, single voxel spectroscopy
IMAGING TECHNIQUES
iPAT, mSENSE and GRAPPA (image, k-space), noncontrast angiography, radial motion compensation, Dixon
MINIMUM TR
3-D GRE: 1.5 (256 matrix)
MINIMUM TE
3-D GRE: 0.63 (256 matrix)
FOV
0.5 - 50 cm
BORE DIAMETER
or W x H
At isocenter: L-R 70 cm, A-P 55 cm
TABLE CAPACITY
250 kg
MAGNET WEIGHT (gantry included)
8200 kg
DIMENSION H*W*D (gantry included)
173 x 230 x 222 cm
5-GAUSS FRINGE FIELD
2.6 m / 4.6 m
CRYOGEN USE
Zero boil off rate, refill approx. 10 years
COOLING SYSTEM
Water
up to 200 T/m/s
MAX. AMPLITUDE
45 mT/m
Passive, active; first order, second order standard
POWER REQUIREMENTS
380 / 400 / 420 / 440 / 460 / 480 V, 3-phase + ground; 110 kVA
spacer
MRI Resources 
Calculation - Collections - MRI Reimbursement - Stent - Mobile MRI - Manufacturers
 
previous      16 - 20 (of 22)     next
Result Pages : [1]  [2 3 4 5]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]