| Info Sheets |
| | | | | | | | | | | | | | | | | | | | | | | | |
| Out- side |
| | | | |
|
| | | | | | | Searchterm 'Spatial Resolution' was also found in the following services: | | | | |
| | |
| |
|
Device Information and Specification CLINICAL APPLICATION Whole body SE, IR, 2D/3D TurboSE, Turbo IR, Dark-Fluid IR, True IR, 2D/3D MEDIC, 2D/3D GRE FLASH, 2D/3D GRE FISP, 2D/3D PSIF, 2D TurboFLASH, 3D MP-RAGE, 3D TurboFLASH, 2D/3D TOF angiography, MTC, TONE with 3D TOF MRA, GMR, LOTA IMAGING MODES Single, multislice, volume study, multi angle, multi oblique178 images/sec at 256 x 256 at 100% FOV1024 x 1024 full screen display POWER REQUIREMENTS 380/400/420/440/480 V Passive, act.; 1st order std./2nd opt. | | | | | |
| | | Searchterm 'Spatial Resolution' was also found in the following service: | | | | |
| | |
| |
|
From ONI Medical Systems, Inc.;
MSK-Extremeâ„¢ MRI system is a dedicated high field extremity imaging device, designed to provide orthopedic surgeons and other physicians with detailed diagnostic images of the foot, ankle, knee, hand, wrist and elbow, all with the clinical confidence and advantages derived from high field, whole body MRI units. The light weight (less than 650 kg) of the OrthOne System performs rapid patient studies, is easy to operate, has a patient friendly open environment and can be installed in a practice office or hospital, all at a cost similar to a low field extremity machine.
New features include a more powerful operating system that offers increased scan speed as well as a 160-mm knee coil with higher signal to noise ratio, and the option of a CD burner.
Device Information and Specification 16 cm knee, 18 cm lower extremity;; 12.3 cm upper extremity, additional high resolution v-SPEC Coils: 80 mm, 100 mm, or 145 mm. SE, FSE, GE2D, GE3D, Inversion recovery (IR), Driven Equilibrium, Fat Saturation (FS), STIR, MT, PD, Flow Compensation (FC), RF spoiling, MTE, No Phase Wrap (NPW) IMAGING MODES Scout, single, multislice, volume 2D less than 200 msec/image X/Y: 64-512; 2 pixel steps 4,096 grey lvls; 256 lvls in 3D POWER REQUIREMENTS 115VAC, 1phase, 20A; 208VAC, 3 phase, 30A COOLING SYSTEM TYPE LHe with 2 stage cold head 1.25m radial x 1.8m axial
| | | | | Further Reading: | Basics:
|
|
| |
| | | | | |
| |
|
From MagneVu;
The MagneVu 1000 is a compact, robust, and portable, permanent magnet MRI system and operates without special shielding or costly site preparation.
This MRI device utilizes a patented non-homogeneous magnetic field image acquisition method to achieve high performance imaging. The MagneVu 1000 MRI scanner is designed for MRI of the extremities with the current specialty areas in diabetes and rheumatoid arthritis. Easy access is afforded for claustrophobic, pediatric, or limited mobility patients. In August 1998
FDA marketing clearance and other regulatory approvals have been received. Until 2008, over 130 devices in the US are in use. Some further developments of MagneVu's extremity scanner are: 'truly Plug n' Play MRI™' and iSiS ( which adds wireless capability to the second generation MV1000-XL).
Device Information and Specification IMAGING MODES 3-dimensional multi-echo data acquisition | | | | • View the DATABASE results for 'MagneVu 1000' (3).
| | | | Further Reading: | News & More:
|
|
| |
| | | Searchterm 'Spatial Resolution' was also found in the following services: | | | | |
| | |
| |
|
(McAb) Monoclonal antibodies are used for tumor detection and localization in nuclear medicine. In MRI, monoclonal antibodies labeled with paramagnetic or superparamagnetic particles are being studied for targeting tumors, for example contrast agent containing gadolinium attached to a targeting antibody. The antibody would bind to a specific target (e.g., a metastatic melanoma cell) while the gadolinium would increase the MRI signal. Further developments are MRI contrast agents that specifically target glucose receptors on tumor cells; coupled with the high spatial resolution of high field MRI devices, these agents have potentials to detect small tumor foci.
The monoclonal antibody manufacturers produce a wide variety of ligands, which can be directed against a multiplicity of pathologic molecular targets. MRI enhanced with targeted contrast agents can be used for molecular imaging. | | | | • View the DATABASE results for 'Monoclonal Antibodies' (4).
| | | | Further Reading: | News & More:
|
|
| |
| | | Searchterm 'Spatial Resolution' was also found in the following service: | | | | |
| | |
| |
|
| | | | • View the DATABASE results for 'Multi Echo Data Image Combination' (2).
| | | | |
| | | | |
| |
| | | |
|
| |
| Look Ups |
| |